Advertisement

PRODUCT CONFIGURATION
CAUTION Federal Law (U.S.A) restricts this device to sale by or on the order of a physician.
Bio Protech Inc.
Manufactured by
Donghwa Medical Instrument complex, 151-3, Donghwagongdan-ro, Munmak-eup,
Wonju-si, Gangwon-do, 26365 Korea
Tel: 82-33-735-7720 , Fax : 82-33-735-7736
Made in China.
EMS Unit x 1
Electrodes x 4
Leadwire x 2
9V Battery, type 6F22 x 1
Instruction Manual x 1
Carring Case x 1
Rev.005 05/2017
INSTRUCTION MANUAL
for the
MAXEMS 2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAXEMS 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for BIO PROTECH MAXEMS 2000

  • Page 1 PRODUCT CONFIGURATION INSTRUCTION MANUAL for the EMS Unit x 1 MAXEMS 2000 Electrodes x 4 Leadwire x 2 9V Battery, type 6F22 x 1 Instruction Manual x 1 Carring Case x 1 CAUTION Federal Law (U.S.A) restricts this device to sale by or on the order of a physician.
  • Page 2: Table Of Contents

    13. ELECTRODE OPTIONS 14. ELECTRODE PLACEMENT 15. TIP FOR SKIN CARE 16. APPLICATION OF RE-USABLE SELF ADHESIVE ELECTRODES 17. ADJUSTING THE CONTROLS 18. INSTRUCTION FOR USE 19. MAINTENANCE, TRANSPORTATION AND STORAGE OF MAXEMS 2000 20. SAFETY-TECHNICAL CONTROLS 21. MALFUNCTIONS 22. WARRANTY...
  • Page 3: Introduction

    Chapter 1: INTRODUCTION 6. Stimulation should not be applied over swollen, infected, or inflamed areas or skin eruptions, e.g., phlebitis, thrombophlebitis, varicose veins, etc. 7. Stimulation should not be applied over, or in proximity to, cancerous lesions. EXPLANATION OF EMS 8.
  • Page 4: General Description

    Chapter 6: GENERAL DESCRIPTION Chapter 8: TECHNICAL SPECIFICATIONS The MAXEMS 2000 is a battery operated pulse generator that sends electrical The technical specification details of MAXEMS 2000 are as follows. impulses through electrodes to the body and reaches the underlying muscle group.
  • Page 5: Accessories

    1. Waveform Chapter 11: ATTACHMENT OF ELECTRODE LEAD WIRES Asymmetrical biphasic pulse The wires provided with the system insert into the jack sockets located on top of the device. Holding the insulated portion of the connector, push the plug end of the wire into one of the jacks (see drawing);...
  • Page 6: Electrode Placement

    Chapter 16: APPLICATION OF RE-USABLE SELF Chapter 14: ELECTRODE PLACEMENT ADHESIVE ELECTRODES The placement of electrodes can be one of the most important parameters in Application achieving success with EMS therapy. Of utmost importance is the willingness of 1. Clean and dry skin at the prescribed area thoroughly with soap and water prior the clinician to try the various styles of electrode placement to find which method to application of electrodes.
  • Page 7: Adjusting The Controls

    Chapter 17: ADJUSTING THE CONTROLS 3. Lead-wire Connector Connection of the electrodes is made with a two-lead connector. The device 1. Slide Cover must be switched off before connecting the cables. Both intensity controls A slide-on panel covers the controls for must be at the off position.
  • Page 8 8. Step to Set Parameter d. Set Ramp Time The parameter of a treatment course can be adjusted according to the following This ramp time controls the time of output current that increases from 0 to the steps. Press “Select” button to select the function you wish to set. setting level and from the setting value to 0.
  • Page 9: Instruction For Use

    8) Gradually (slowly) increase the intensity until the patient experiences the first g. Set Timer ‘tingling’ sensation from the stimulator. The treatment time can be adjusted 15 minutes, 30 minutes, 45 minutes, 9) Gradually (slowly) increase the intensity further until the patient experiences 60 minutes.
  • Page 10: Malfunctions

    Do not try to repair a defective device. Chapter 22: WARRANTY All MAXEMS 2000 models carry a warranty of one year from the date of delivery. The warranty applies to the stimulator only and covers both parts and labor relating thereto.