[6] & [7] Supervision Options
[6]
[7]
RF Zone Supervision Options (except SP4000)
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed: Trouble only
When armed: Follow zone's alarm type
ON
ON
When disarmed: audible alarm
When armed: Follow zone's alarm type
[8]
Generate supervision on bypassed zone
[706]
General Zone Options
Option
[1]
Check-in supervision time (except SP4000)
[2]
EOL resistors*
Zone Input 1 becomes a 2-wire smoke input (except SP5500/SP4000)  Disabled
[3]
[4]
ZX8 ID A (Panel + 1) Input 1
[5]
ZX8 ID B (Panel + 9) Input 1
[6]
ZX8 ID C (Panel + 17) Input 1
*This option applies to all hardwired zones (panel, keypad, ZX8)
Zone Timers (MG Series)
Note that When both ATZ and EOL are enabled, zone speed should not be set below 300ms.
Section
MG5000
[041] Zone 1
(Z1)
[042] Zone 2
(Z2)
[043] Zone 3
(Z1 ATZ)
[044] Zone 4
(Z2 ATZ)
[045] Zone 5
[046] Zone 6
[047] Zone 7
[048] Zone 8
[049] Zone 9
[050] Zone 10
[051] Zone 11
[052] Zone 12
[053] Zone 13
[054] Zone 14
[055] Zone 15
[056] Zone 16
Zone Timers (SP Series)
NOTE: When both ATZ and EOL are enabled, zone speed should not be set below 300ms.
Section
SP4000
[041] Zone 1
(Z1)
[042] Zone 2
(Z2)
[043] Zone 3
(Z3)
[044] Zone 4
(Z4)
[045] Zone 5
(Z1 ATZ) (Z5)
[046] Zone 6
(Z2 ATZ) (Z1 ATZ) (Z6)
[047] Zone 7
(Z3 ATZ) (Z2 ATZ) (Z7)
[048] Zone 8
(Z4 ATZ) (Z3 ATZ) (Z8)
[049] Zone 9
[050] Zone 10
[051] Zone 11
[052] Zone 12
[053] Zone 13
[054] Zone 14
[055] Zone 15
[056] Zone 16
* SP7000: For zones 17-32 (ATZ), the zone timer is set at 0.6 seconds.
Magellan / Spectra SP
MG5050
Data
(Z1)
____/____/____
(Z2)
____/____/____
(Z3)
____/____/____
(Z4)
____/____/____
(Z5)
____/____/____
(Z1 ATZ)
____/____/____
(Z2 ATZ)
____/____/____
(Z3 ATZ)
____/____/____
(Z4 ATZ)
____/____/____
(Z5 ATZ)
____/____/____
____/____/____
____/____/____
____/____/____
____/____/____
____/____/____
____/____/____
SP5500
SP6000
SP7000* Data
(Z1)
(Z1)
(Z1)
(Z2)
(Z2)
(Z2)
(Z3)
(Z3)
(Z3)
(Z4)
(Z4)
(Z4)
(Z5)
(Z5)
(Z6)
(Z7)
(Z8)
(Z4 ATZ) (Z1 ATZ)
(Z9)
(Z5 ATZ) (Z2 ATZ)
(Z10)
(Z3 ATZ)
(Z11)
(Z4 ATZ)
(Z12)
(Z5 ATZ)
(Z13)
(Z6 ATZ)
(Z14)
(Z7 ATZ)
(Z15)
(Z8 ATZ)
(Z16)
Keypad / Bus Module Supervision Options
Disabled
Trouble only
Trouble only
Trouble only
No
OFF
 24 hours
 Disabled
 Zone input
 Zone input
 Zone input
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
____/____/____
(000 to 255) x 10ms
 Yes
ON

80 minutes
Enabled
Enabled
Tamper input
Tamper input
Tamper input
Description (Default 060)
Hardwire Zone 1 Speed
Hardwire Zone 2 Speed
Hardwire Zone 3 Speed
Hardwire Zone 4 Speed
Hardwire Zone 5 Speed
Hardwire Zone 6 Speed
Hardwire Zone 7 Speed
Hardwire Zone 8 Speed
Hardwire Zone 9 Speed
Hardwire Zone 10 Speed
Hardwire Zone 11 Speed
Hardwire Zone 12 Speed
Hardwire Zone 13 Speed
Hardwire Zone 14 Speed
Hardwire Zone 15 Speed
Hardwire Zone 16 Speed
Description (Default 060)
Hardwire Zone 1 Speed
Hardwire Zone 2 Speed
Hardwire Zone 3 Speed
Hardwire Zone 4 Speed
Hardwire Zone 5 Speed
Hardwire Zone 6 Speed
Hardwire Zone 7 Speed
Hardwire Zone 8 Speed
Hardwire Zone 9 Speed
Hardwire Zone 10 Speed
Hardwire Zone 11 Speed
Hardwire Zone 12 Speed
Hardwire Zone 13 Speed
Hardwire Zone 14 Speed
Hardwire Zone 15 Speed
Hardwire Zone 16 Speed
17