Table 109 - DC-bus Power Supply Behavior, FLT Sxx Fault Codes
Exception Fault Code
FLT S15 – CONV OVERCURRENT
FLT S16 – GROUND CURRENT
FLT S18 – CONV OVERTEMP FL
FLT S20 – CONV OVERLOAD FL
FLT S21 – CONV OVERLOAD UL
FLT S23 – AC PHASE LOSS
FLT S25 – PRECHARGE FAILURE
(1)
FLT S27 – BUS REG OVERTEMP FL
FLT S29 – BUS REG OVERLOAD FL
FLT S30 – BUS REG OVERLOAD UL
DC-bus Power Supply Behavior
Stopping action for exception fault codes does not apply to the DC-bus power
supply. The StopDrive exception action for a DC-bus power supply means the
power supply enters into a Major Fault state that opens the contactor-enable
output, removing three-phase power from the Kinetix 5700 drive system. The
Shutdown exception action exhibits the same behavior as Stop Drive, except
the power supply enters into Shutdown as the final state and requires a
Shutdown Reset to recover.
Fault actions are shown in
Figure 102 - Logix Designer Axis Properties - Exceptions Category
Exception Text
Converter Overcurrent Fault
Ground Current Factory Limit Fault
Converter OverTemp Factory Limit Fault
Converter Thermal OverLoad Factory Limit Fault
Converter Thermal Overload User Limit Fault
AC Single Phase Loss Fault
Precharge Failure Fault
Bus Regulator Overtemperature Factory Limit Fault
Bus Regulator Thermal OverLoad Factory Limit Fault
Bus Regulator Thermal Overload User Limit Fault
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Troubleshoot the Kinetix 5700 Drive System
Table 109
and
Table
110.
Module
DC-bus PS
DC-bus PS
DC-bus PS
DC-bus PS
DC-bus PS
X
X
DC-bus PS
DC-bus PS
DC-bus PS
DC-bus PS
DC-bus PS
X
X
Chapter 7
Fault Action
X
X
X
X
X
X
X
X
X
X
X
X
227
Need help?
Do you have a question about the Kinetix 5700 and is the answer not in the manual?
Questions and answers