Operating Instructions IQ-ONE / IQ-ONE+ Operating Philosophy Bräuniger GmbH’s philosophy is to produce user-friendly instruments. A quick press of each key lets you access the main functions of the instrument. Hold a key down for about three seconds to call up Set-Mode for that function. From there, a further three-second press will call up Option-Mode for that key.
Operating Instructions IQ-ONE / IQ-ONE+ Key Functions Acoustics Height and Change keys Memo keys Value keys Elements of the Display Integrated / digital Vario Analogue vario Barometric Height 1 or Height 2 Sink Warning On / OFF Speed or Temperature...
Operating Instructions IQ-ONE / IQ-ONE+ Switching the Instrument ON/OFF The date and time are displayed when the instrument is off. To turn it on, press and hold the Key until you hear a beep, TIME/CHRONO/MEMO and then release it. After a short display test you will see the Start up Screen.
Operating Instructions IQ-ONE / IQ-ONE+ Quick Operating Instructions Quick operating instructions – direct choice keys Quick touch in RUN Long hold in RUN Functions in SET Functions in OPTION mode mode mode mode CHRONO Reset CHRONO when Change Choice/change Start -Stop...
Operating Instructions IQ-ONE / IQ-ONE+ The Altimeter General How does an altimeter function? An altimeter is really a barograph because it doesn’t directly measure height, but air pressure. Height is calculated from changes in air pressure. The pressure at sea level is used as zero height for the calculation of real height (after the international height formula).
Operating Instructions IQ-ONE / IQ-ONE+ short Setting options Function keys Option ALT 1 Height Unit Unit Corr Alti 1 Sensor ALT 1 m, ft hPa, inHg correction -47.9 to 47.9 ALT 2 Height Unit REL/AbS ALT2 (m/ft) Mode A2 ALT 2...
Operating Instructions IQ-ONE / IQ-ONE+ Option-Mode ALT1 Further long pressure on the Set-Mode key brings the instrument into Option-Mode. Option 1 Unit The units of height to be displayed are set here. Option 2 Unit For the ALT1 value hPa or inHg pressure units can be chosen.
Operating Instructions IQ-ONE / IQ-ONE+ Option-Mode ALT2 Further long pressure on the Set-Mode key brings the instrument into Option-Mode. Option 1 Unit The units of height to be displayed are set here. Relative height, ALT2 only Option 2 Rel For the ALT2 value, relative or absolute values can be chosen.
Operating Instructions IQ-ONE / IQ-ONE+ Variometer The Variometer, the most important instrument, can be adjusted to the pilots’ requirements. Short Audio keys Audio Option setting Volume A-Int Unit d-Int Audio Audio Integra- On/Off Basic Pitch 6 levels Max. at VARIO...
Operating Instructions IQ-ONE / IQ-ONE+ Vario Set-Mode Press the Vario Key for three seconds to put the instrument into Vario Set-Mode. A-Int = Analogue Integrator The basic damping of the Variometer is set here. Four levels are displayed. The damping corresponds with the following times.
Page 13
Operating Instructions IQ-ONE / IQ-ONE+ Audio Pitch Option 4 Audio Pitch The range of the peep frequency can be set to different climb rates. Maximum peep frequency frequency Start of audio output 5 m/s 10 m/s Vario Audio Scale Indication Option 5 ASI The audio scale indicator can be set to on or off (ON/OFF).
- so it may not match the ambient air temperature. Note: The IQ-ONE can accept input from an optional Vane Wheel Airspeed sensor. (available separately) The plug-in port for the sensor is on the left side of the instrument.
Page 15
Operating Instructions IQ-ONE / IQ-ONE+ Option 3 Unit ( Set speed units ) Units for the speed display are chosen here. The choices are km/h or kts and mph. Option 4 Stall ( Stall Speed ) The stall alarm sounds when flying too slowly results in an interruption to the laminar flow.
During the MEMO display you can change between the actual flight and stored flights using the arrow key. The actual flight is not disrupted. display, when barograph recording is enabled MEMO [Model IQ-ONE+ only], the instrument will revert automatically after twelve seconds to display. TIME Bräuniger GmbH...
Operating Instructions IQ-ONE / IQ-ONE+ Set-Mode TIME Further long pressure on the TIME key brings the instrument into Time-Set-Mode. The Time-Set-Mode is only active when no flight recording takes place. Please note, when switching off, the longer hold will take you into this menu, even if no flight recording was active.
A data port on the right side of the instrument allows you to connect the IQ-ONE+ to a computer (on Model IQ-ONE there is a plastic plug in this location in lieu of the connector).
Page 19
Operating Instructions IQ-ONE / IQ-ONE+ A recording interval of 1 second is displayed first. After further pressure on the Up key 5, and then 15 seconds are displayed. The parameters that can be recorded are set in Option-Mode MEMO. Barograph storage capacity.
Page 20
Operating Instructions IQ-ONE / IQ-ONE+ The instrument transfers all recorded data to the barograph at 2 minute intervals. In the worst case scenario, only the last two minutes of data can be missing from the barogram. At Del Baro (gram) the number of the flight to be deleted is shown at the top.
Operating Instructions IQ-ONE / IQ-ONE+ Option-Mode MEMO Further long pressure in the Set-Mode brings the instrument into Option Mode MEMO. The parameters to be recorded on the barogram are set here. The choice is between: - ALT1: only height 1 - °...
Operating Instructions IQ-ONE / IQ-ONE+ Maintenance and Care Water Damage Water damage invalidates the guarantee. If the instrument suffers water damage, proceed as follows. Remove the batteries at once. Rinse the instrument with fresh warm water. Dry the instrument (e.g. warm air, hair dryer).
Page 23
Operating Instructions IQ-ONE / IQ-ONE+ display: ° F or ° C resolution: 0.1° C (0.1° F ) accuracy: ± 0.5° C, calibration possible Time Functions: real time clock (12h/24h) with date stop watch up to 99 hrs 59 min 59 sec automatic calendar, automatic logging Max.