Table of Contents 1 Important information System solution Safety information Serial number Recovery Environmental information Checklist: Checks before commissioning 2 Delivery and handling Transport and storage Assembly Removing the covers 3 The heat pump design Component locationAMS 10 Electrical panel Sensor placement 4 Pipe connections 5 Electrical connections...
Marking System solution The CE mark is obligatory for most products sold AMS 10 is intended for installation with NIBE SPLIT Box HBS 05 and indoor module (VVM) or control in the EU, regardless of where they are made. module (SMO) for a complete system solution.
Page 5
If the power supply is not shut off, there is a risk of electric shocks If soldering near the unit, ensure that solder residue does not and damage due to the rotating fan. damage the drip tray. If solder residue enters the unit during soldering, small holes can Do not run the unit with removed panels or protection.
Serial number Caution You need the product’s service code and serial You can find the service code and the serial number (PF3) number for servicing and support. on the right-hand side of AMS 10. Recovery Leave the disposal of the packaging to the in- staller who installed the product or to special waste stations.
Checklist: Checks before commissioning Refrigerant system Notes Checked Pipe length Height difference Pressurization test Leak testing End pressure vacuum Pipe insulation Electrical installation Notes Checked Property's main fuse Group fuse Load monitor / current sensor (Connects to indoor module / control module.) KVR 10 When installing AMS 10-6 / HBS 05-6, check that the software version of the in-...
2 Delivery and handling Transport and storage AMS 10 must be transported and stored vertically. NOTE Ensure that the heat pump cannot fall over during transport. Assembly Place AMS 10 outdoors on a solid level base that can ■ take the weight, preferably a concrete foundation. If concrete slabs are used they must rest on asphalt or shingle.
Page 9
Lift from the street to the set up location Condensation run off If the base allows, the simplest thing is to use a pallet Condensation runs out on to the ground below AMS 10. truck to move the AMS 10 to the set up location. To avoid damage to the house and heat pump, the condensation must be gathered and drained away.
Page 10
Gutter drainage Recommended alternative for leading off condensation water NOTE Drain indoors Bend the hose to create a water seal, see illus- tration. Joint Water seal Water seal Frost free Frostfritt depth djup From air/water heat The condensation water is lead to an indoor drain (sub- pump ject to local rules and regulations).
Page 11
Installation area The recommended distance between AMS 10 and the house wall must be at least 15 cm. Clearance above AMS 10 should be at least 100 cm. However, free space in front must be 100 cm for future servicing 15 cm Free space behind 30 cm...
Page 23
Data for sensor in AMS 10-6 Data for sensor in AMS 10-8, -12, -16 Tho-D Tho-D Motstånd Motstånd Resistor Resistor (kΩ) (kΩ) 90 100 110 120 130 140 150 Tho-D Temperatur (°C) Temperature (°C) Tho-D Temperature (°C) Temperatur (°C) Tho-A, R Tho-S, Tho-R1, Tho-R2 Motstånd Resistor...
This means that one of the phases will be loaded with a number of amperes (A) during compressor operation. NOTE Check the maximum load in the table below. If the supply cable is damaged, only NIBE, its Outdoor module Maximum current (A) service representative or similar authorised...
Incoming supply distribution unit Isolator switch Communication cable Power cable *Current sensor HBS 05 NIBE VVM AMS 10 * Only in a 3-phase installation. Electrical components See component location in chapter The heat pump design, Electrical panel on page 19. Accessibility, electrical...
Connections NOTE To prevent interference, unscreened commu- nication and/or sensor cables to external con- nections must not be laid closer than 20 cm from high voltage cables. Power connection AMS 10 Incoming supply Cable gland AMS 10 Chapter 5 | Electrical connections...
Page 29
Communication connection Communication is connected on terminal block TB. See also electrical wiring diagram on page 56. You can find more information in the Installer Manual for SPLIT box HBS 05. Connecting accessories Instructions for connecting accessories are in the install- ation instructions provided for the respective accessory.
6 Commissioning and adjusting Compressor heater AMS 10 is equipped with a compressor heater (CH) that heats the compressor before start-up and when the compressor is cold. (Does not apply to AMS 10-6.) NOTE The compressor heater must have been connec- ted for 6 –...
7 Control - Heat pump EB101 NOTE For information: See chapter “Control – Heat pump EB101” in the Installer Manual for HBS 05. AMS 10 Chapter 7 | Control - Heat pump EB101...
8 Disturbances in comfort NOTE For more information: See chapter “Disturb- ances in comfort” in the Installer Manual for HBS 05. Chapter 8 | Disturbances in comfort AMS 10...
9 Alarm list Alarm Alarm text on the dis- Description May be due to play ■ High condenser out Too high temperature out from the con- Low flow during heating operation denser. Self-resetting. ■ Too high set temperatures ■ High condenser in Too high temperature into the condenser.
Page 34
Alarm Alarm text on the dis- Description May be due to play ■ High temperature in heat Temperature deviation on the heat ex- Sensor does not work (see section "Dis- exchanger changer sensor (Tho-R1/R2) five times turbances in comfort") within 60 minutes or for 60 minutes con- ■...
Page 35
Alarm Alarm text on the dis- Description May be due to play ■ Sensor fault Tho-D Sensor fault, hot gas in AMS 10 (Tho-D). Open circuit or short circuit on sensor input ■ Sensor does not work (see section "Dis- turbances in comfort") ■...
10 Accessories Not all accessories are available on all markets. Indoor module VVM 310 Air/water heat pump Part no. 069 430 SPLIT box HBS 05 HBS 05-6 VVM 310 Part no. 067 578 With integrated EMK 310 HBS 05-12 Part no.067 480 Part no.
Page 37
Stand and brackets Ground stand For AMS 10-6, -8, -12, -16 Part no. 067 515 Wall bracket For AMS 10-6, -8, -12 Part no. 067 600 AMS 10 Chapter 10 | Accessories...
The sound pressure levels are further affected by walls, Sound pressure levels bricks, differences in ground level, etc and should therefore only be seen as guide values. AMS 10 is usually placed next to a house wall, which gives a directed sound distribution that should be con- sidered.
Page 46
Working range, compressor operation - heating AMS 10 Heating mode Water temperature °C Vattentemperatur (°C) Utomhustemperatur (°C) Supply temperature Outdoor air temperature °C Framledning Return temp Returledning During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up. Framledning Returledning Vattentemperatur (°C)
Page 47
Utomhustemperatur (°C) Working range, compressor operation - cooling AMS 10 Cooling mode Water temperature °C Vattentemperatur (°C) Utomhustemperatur (°C) Supply temperature Outdoor air temperature °C Framledning Return temp Returledning Framledning Returledning AMS 10 Chapter 11 | Technical data...
Page 48
Max. specified power AMS 10-8 Output and COP at different supply F2040-8 Max avgiven effekt temperatures Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW) 12,00 Maximum capacity including defrosting. 10,00 Max. specified power AMS 10-6 F2040-6 Max avgiven effekt 8,00 Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW)
Tel: +7 831 419 57 06 E-mail: kuzmin@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46 (0)433 73 000 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information.
Need help?