Download Print this page
Asco 400 Series Installation & Operation Manual

Asco 400 Series Installation & Operation Manual

Surge protective device, nema 4x non metallic a/c monitoring option, nema 12 steel a monitoring option
Hide thumbs Also See for 400 Series:

Advertisement

Quick Links

Surge Protective Devices
Installation & Operation Manual
NEMA 4X (Non-Metallic)
"A" Monitoring Option
NEMA 4X (Non-Metallic)
"C" Monitoring Option
NEMA 12
(Steel)
"A" Monitoring
Option
Model 445
Model 440

Advertisement

loading
Need help?

Need help?

Do you have a question about the 400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Asco 400 Series

  • Page 1 Surge Protective Devices Installation & Operation Manual NEMA 4X (Non-Metallic) “A” Monitoring Option NEMA 4X (Non-Metallic) “C” Monitoring Option Model 445 Model 440 NEMA 12 (Steel) “A” Monitoring Option...
  • Page 2: Installation

    Refer to quick start guide QS-70100 or manual IO-70109 for additional installation and operation instructions. The ASCO Model 445 & 440 Surge Protective Devices are high quality, high energy surge current diversion system designed to protect sensitive equipment from damaging transient voltage surges resulting from load switching, lightning strikes and other sources.
  • Page 3 Environment: The unit is designed for operation indoors in ambient temperatures of -35ºC (-31ºF) to +85ºC (+185ºF) with a relative humidity of 0% to 95% (non-condensing). The unit is provided in an industrial enclosure, which should not be installed in areas with excessive dust, corrosive vapors, flammable materials or explosive atmospheres.
  • Page 4 Model 440 Number Configurator & Options   Model 440 Voltage Codes Per Phase kA Rating Modes of Product Line kA Rating Per Phase Protection System (Default) Common Systems 10 = 100kA 120S = 240/120V Split Phase - 1Ø, 3W+Grnd, (Fig 1) 20 = 200kA 120Y = 208Y/120V Wye - 3Ø...
  • Page 5 Model 440 Number Configurator & Options      Connection Monitoring Enclosure UL 1449 Accessory/ Type Options Type1/Type 2 Option(s) C = Compression 1 = UL 1449 Type 1 Lugs 2 = UL 1449 Type 2, W = Wire Leads (Includes UL1283 Filter) 0 = No Trailing A = LEDs/Audible Alarm/Relay...
  • Page 6 If all connections are reliable, and proper voltages are supplied to the unit, call ASCO Surge Protection, Inc at 800-237-4567. N-G Overvoltage Indication: If all green “PHASE” LEDs are ON and red “SERVICE” LED is also ON this indicates that the neutral to ground voltage at the connected panel may be 20 VAC or higher.
  • Page 7 DIMENSIONAL INFORMATION for Non-Metallic NEMA 4X Enclosure Option (“J”) Unit Weight Model 445/440 9.6” [244] 4.9” [124] 3.2” [81] 9” [229] 3.5” [90] 4.4 lbs [2.0kg] 1/2 NPT flexible conduit (12”) and connector assembly included. [102] 2.0 [52] DIMENSIONAL INFORMATION for Steel Enclosure Option (NEMA 12 = “L”) Unit Weight...
  • Page 8 14550 58th Street North While every precaution has been taken to ensure accuracy and completeness in this literature, ASCO assumes no responsibility, and disclaims all liability for Clearwater, Florida 33760 damages resulting from use of this information or for any errors or omissions.

This manual is also suitable for: