Error Codes And Fault Fi Nding - Atag iC 24 Installation & Servicing Instructions Manual

Hide thumbs Also See for iC 24:
Table of Contents

Advertisement

17 Error codes and fault fi nding
A detected failure is indicated on the display in blocking or error messages.
- Blocking
Error is temporary and will cancel itself or will lock the boiler after several attempts (error)
- Error
Error means a lock on the boiler and can only be remedied by a reset and/or intervention by a service
technician.
10
Outside sensor error (e.g. open, short circuit, out of range)
20
Flow sensor error (e.g. open, short circuit, out of range)
40
Return sensor error (e.g. open, short circuit, out of range)
50
T3 (DHW) sensor error (e.g. open, short circuit, out of range)
61
Bus communication error (contact open)
78
Water pressure outside of range or not connected
105
Venting program active when power turned on or interrupted (runs approx. 7 mins.)
110
Safety temperature exceeded
111
Maximum temperature exceeded
117
Pressure too high (> 3 bar) or pump pressure increase too high
118*
Pressure too low (0.5 - 0.8 bar) or pump pressure increase too low (no pump detection)
119
Link on X2 position 4 and 5 missing
129
Fan error (fan does not start up)
133
No fl ame after 5 ignition attempts
151
Fan error (speed control is not achieved or is out of range) or control unit defective
154
Flow increases too fast ∆T too large, return > fl ow
180
No error: shortly visible when leaving chimney sweep function
181
No error: shortly visible when leaving commissioning mode
Example of display of error message
Installation & Servicing instructions ATAG iC-Range
code with spanner symbol
code with bell symbol
* First measure to solve fault code 118:
Manually deblocking of the boiler pump.
53

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iC 24 and is the answer not in the manual?

Questions and answers

Table of Contents