Series TY-FRB – 5.6 and 8.0 K-factor
Conventional (Old Style) Sprinklers
Quick Response
General
Description
The TYCO Series TY-FRB, 5.6 and
8.0 K-factor, Conventional Sprinklers
described in this technical data sheet
are Quick Response, Standard Cover-
age, decorative 3 mm glass bulb type
spray sprinklers. These sprinklers are
intended to be installed either pendent
or upright and, in either position,
produce a spherical water discharge
pattern with approximately 50% of
the discharge directed upwards and
approximately 50% of the discharge
directed downwards.
Conventional sprinklers are generally
used with Ordinary and Extra High
Hazard Class Systems, as defined by
the automatic sprinkler system instal-
lation rules of the country and author-
ity having jurisdiction. The National Fire
Protection Association (NFPA) permits
the use of "Old Style Sprinklers" where
special construction features require a
unique water distribution, for the pro-
tection of fur vaults, or to replace similar
sprinklers that had been installed prior
to 1955.
Corrosion-resistant coatings, where
applicable, are utilized to extend the life
of copper alloy sprinklers beyond that
which would otherwise be obtained
when exposed to corrosive atmo-
spheres. Although corrosion-resistant
coated sprinklers have passed the
standard corrosion tests of the appli-
cable Approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently,
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4
it is recommended that the end user
be consulted with respect to the suit-
ability of these coatings for any given
corrosive environment. The effects of
ambient temperature, concentration of
chemicals, and gas/chemical velocity
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
NOTICE
The TYCO Series TY-FRB Sprinklers
described herein must be installed
and maintained in compliance with this
document, as well as with the applica-
ble standards of the NFPA, in addition
to the standards of any other authori-
ties having jurisdiction. Failure to do so
may impair the performance of these
devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Numbers (SINs)
TY3631 – 5.6K, 1/2" NPT
TY4631 – 8.0K, 3/4" NPT
JANUARY 2017
Worldwide
www.tyco-fire.com
Contacts
Technical
Data
Approvals
UL and C-UL Listed
LPCB Approved
VdS Approved
NYC Approved
(Refer to Table A for complete approval
information.)
Sprinklers with Polyester Finish are UL
and C-UL Listed as Corrosion-Resistant
Sprinklers.
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=5.6 gpm/psi
1/2
(80,6 lpm/bar
K=8.0 gpm/psi
1/2
(115,2 lpm/bar
Temperature Ratings
Refer to Table A
Finishes
Sprinkler: Refer to Table A
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze
Button . . . . . . . . . . . . . . . . . . . . . . Brass/Copper
Sealing Assembly . . Beryllium Nickel w/TEFLON
Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass
Compression Screw . . . . . . . . . . . . . . . . .Bronze
Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Copper
1/2
)
1/2
)
TFP666

Advertisement

loading
Need help?

Need help?

Do you have a question about the TY-FRB Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Tyco TY-FRB Series

  • Page 1 Description ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of The TYCO Series TY-FRB, 5.6 and chemicals, and gas/chemical velocity 8.0 K-factor, Conventional Sprinklers should be considered, as a minimum, described in this technical data sheet...
  • Page 2 1/16 inch FIGURE 2 (1,6 mm) for the 135°F (57°C) to 3/32 W-TYPE 6 The TYCO Series TY-FRB Conventional inch (2,4 mm) for the 286°F (141°C) SPRINKLER WRENCH Sprinklers are intended for fire protec- temperature ratings.
  • Page 3 4. Approved by the City of New York under MEA 354-01-E 5. VdS Approved (For details, contact Tyco Fire Protection Products, Enschede, Netherlands, Tel. +31-53-428-4444 / Fax +31-53-428-3377.) 6. Where polyester-coated and lead-coated sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-...
  • Page 4 (specify) finish, P/N (specify from Table Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. TEFLON is a registered trademark of DuPont...

This manual is also suitable for:

Ty-frb 5.6Ty-frb 8.0Ty3631Ty4631