SPECIAL PRECAUTIONS For Schier Grease Interceptor Installations - Failure to follow this guidance voids your warranty DO NOT AIR TEST UNIT OR RISER SYSTEM! Do not install this unit in any manner Doing so may result in property damage, personal injury or death.
Page 3
SPECIAL PRECAUTIONS For Schier Grease Interceptor Installations - Failure to follow this guidance voids your warranty High Water Table Installations Fully Support Base of Unit Install unit on solid, level surface in concrete floor max water table height contact with the entire footprint of for direct burial unit base;...
They do not require an external flow control Figure A system or air intake vent. Schier grease interceptors are not to be installed in any other manner except as shown. Consult local codes for separate trapping requirements, cleanout locations and additional installation instructions.
5. If tilting of the adapter is required to be flush with grade, do so AFTER all clamps have been tightened with riser(s)/adapter in a vertical and level position. Tilting is done using gasket flexibility. Tilting before tightening clamps may ruin a perfect gasket seal. Schier recommends tilting only the adapter versus the entire riser assembly to make sure your riser height and proper tank access is maintained.
Add this vent if unit is installed one or more floors below the Must be fully fixtures being served supported *Venting examples shown are typical, check local code for requirements Recessed and Suspended Additional Venting for Floor-Below Installations GB-50 Installation Guide Page 7 of 7...