Features............................... 14 Installation and starting up........................ 15 Connections and controls........................16 Technical specifications........................21 Plug and connection assignment....................37 Cleaning............................... 41 Protecting the environment......................42 TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
General information General information This user manual contains important information on the safe operation of the device. Read and follow all safety notes and all instructions. Save this manual for future reference. Make sure that it is available to all persons using this device. If you sell the device to another user, be sure that they also receive this manual.
Personal consultation For personal consultation please contact our technical hotline. If you have any problems with the device the customer service will Service gladly assist you. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
General information 1.2 Notational conventions This manual uses the following notational conventions: Letterings The letterings for connectors and controls are marked by square brackets and italics. Examples: [VOLUME] control, [Mono] button. Cross-references References to other locations in this manual are identified by an arrow and the specified page number.
Page 7
Warning signs Type of danger Warning – high-voltage. Warning – danger zone. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Safety instructions Safety instructions Intended use This device amplifies electric audio frequency signals to operate passive speakers. Use the device only as described in this user manual. Any other use or use under other operating con‐ ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
Page 9
Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a regis‐ tered electrician. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 10
Safety instructions CAUTION! Possible hearing damage The device can produce volume levels that may cause temporary or permanent hearing impairment. Over an extended period of time, even levels that seem to be uncritical can cause hearing damage. Decrease the volume level immediately if you experience ringing in your ears or hearing impairment.
Page 11
This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 12
Safety instructions NOTICE! Power supply Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user.
Page 13
The use of different types of fuses can cause serious damage to the unit. Fire hazard! Only fuses of the same type may be used. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Connections and controls Connections and controls Front panel power amplifier...
Page 17
CH-A and CH-B to their minimum levels. If the LEDs are still permanently lit, the device must be checked by an authorized technical service centre. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 18
Connections and controls Rear panel power amplifier...
Page 19
Switch for operating modes ‘STEREO’ (channels operate independently of each other), ‘PARALLEL’ (two channels are interconnected) and ‘BRIDGED’ (two channels are interconnected to form one channel with double output). TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 20
Connections and controls 10 [Lift | Ground] selector switch The Ground/Lift switch allows you to interrupt the connection between the device’s protective earth terminal and signal ground in order to prevent hum loops (Lift/unpressed state: disconnected. ‘Ground’ position / switch pressed: Earth pin and signal ground are electrically connected).
< 0.01 % / 160 W Crosstalk < 60 dB Frequency response 20 Hz … 20 kHz (+ 0.1 …– 3 dB, 1 W, 8 Ω) TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 22
Technical specifications Signal-to-noise ratio 103 dB Total harmonic distortion (THD) < 0.05 % / 250 W 4 Ω at 1 kHz Damping factor (8 Ω, 1 kHz) 300:1 Sensitivity 0,775 V at rated power (8 W) Gain 34 dB Cooling 2 ×...
Page 23
Technical specifications Ambient conditions Temperature range 0 °C…40 °C Relative humidity 50 %, non-condensing TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 24
Technical specifications TA 600 MK-X Amplifier class Input impedance 20 kΩ (balanced) 10 kΩ (unbalanced) Output power 8 Ω, stereo 2 × 220 W 4 Ω, stereo 2 × 330 W 8 Ω, mono bridged 640 W Slew rate 40 V/ms Common mode rejection >...
Page 25
5 mm × 20 mm, 10 A, 250 V, fast blow Dimensions (W × H × D) 485 mm × 103 mm × 470 mm Weight 13.7 kg TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 26
Technical specifications Ambient conditions Temperature range 0 °C…40 °C Relative humidity 50 %, non-condensing power amplifier...
Page 27
< 0.01 % / 400 W Crosstalk < 60 dB Frequency response 20 Hz … 20 kHz (+ 0.1 …– 3 dB, 1 W, 8 Ω) Signal-to-noise ratio 103 dB TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 28
Technical specifications Total harmonic distortion (THD) < 0.05 % / 620 W 4 Ω at 1 kHz Damping factor (8 Ω, 1 kHz) 300:1 Sensitivity 0,775 V at rated power (8 W) Gain 34 dB Cooling 2 × 2-speed DC fan Power consumption Load 1/8 nominal power...
Page 29
Technical specifications Ambient conditions Temperature range 0 °C…40 °C Relative humidity 50 %, non-condensing TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 30
Technical specifications TA 1400 MK-X Amplifier class Input impedance 20 kΩ (balanced) 10 kΩ (unbalanced) Output power 8 Ω, stereo 2 × 570 W 4 Ω, stereo 2 × 850 W 8 Ω, mono bridged 1600 W Slew rate 40 V/ms Common mode rejection >...
Page 31
5 mm × 20 mm, 15 A, 250 V, fast blow Dimensions (W × H × D) 483 mm × 103 mm × 475 mm Weight 17.5 kg TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 32
Technical specifications Ambient conditions Temperature range 0 °C…40 °C Relative humidity 50 %, non-condensing power amplifier...
Page 33
< 0.01 % / 760 W Crosstalk < 60 dB Frequency response 20 Hz … 20 kHz (+ 0.1 …– 3 dB, 1 W, 8 Ω) Signal-to-noise ratio 103 dB TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 34
Technical specifications Total harmonic distortion (THD) < 0.05 % / 1200 W 4 Ω at 1 kHz Damping factor (8 Ω, 1 kHz) 500:1 Sensitivity 0,775 V at rated power (8 W) Gain 39.2 dB Cooling 2 × 2-speed DC fan Power consumption Load 1/8 nominal power...
Page 35
2 RU 2 Ω stability DSP / frequency Convection cooling Protection circuits (DC voltage protection, overtempera‐ ture protection, short-circuit protection, infrasound pro‐ tection, overcurrent protection) TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 36
Technical specifications Block diagram power amplifier...
In addition to the conduc‐ tors ‘Ground’ and ‘Signal’, in a balanced transmission a second core is added. This also transfers the signal, but phase-shifted by 180°. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 38
Plug and connection assignment Since the interference affects both cores equally, by subtracting the phase-shifted signals, the interfering signal is completely neutralized. The result is a pure signal without any noise inter‐ ference. 1/4" TS phone plug (mono, unbalanced) Signal Ground, shielding 1/4"...
Page 39
Signal (left) Signal (right) Ground XLR plug (balanced) Ground, shielding Signal (in phase, +) Signal (out of phase, –) Shielding on plug housing (option) TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Page 40
Plug and connection assignment XLR plug (unbalanced) Ground, shielding Signal Bridged to pin 1 Speaker Twist chassis connector 1, + Signal 1 (in phase) 1, – Signal 1 (out of phase) 2, + Signal 2 (in phase) 2, – Signal 2 (out of phase) power amplifier...
Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth. TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X...
Protecting the environment Protecting the environment Disposal of the packaging mate‐ rial For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling.