B. Wiring Requirements
IntelliFire™ Touch Ignition System Wiring
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance power cord to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 6.2, IntelliFire
Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Ensure the 6 volt transformer is plugged into the supplied
cord assembly to supply power to the unit OR install 4 AA
cell batteries (not included) into the battery pack before
use.
• Reset switch must be installed and in the "ON" position
for appliance to operate.
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
RF MODULE
2166-302 (NG)
2166-303 (LP)
Figure 6.2 IntelliFire™ Touch Wiring Diagram
Heat & Glo • SUPREME-I25-IFT, SUPREME-I30-IFT, SUPREME-I35-IFT Installation Manual • 2532-980 Rev. E • 5/19
28
Touch (IPI) Wiring
TM
FLAME
IGNITER
SENSE
2550-013 (NG)
2550-014 (LP)
2326-131
6V TRANSFORMER
PLUG
2179-300
I
S
2326-150
2326-130
2326-120
6 PIN
BLK
BRN
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
WSK-21-W
Battery Pack
Battery pack is not factory installed in appliances. See
appliance manual bag for battery pack. Battery pack
should only be installed during power outages.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
DO not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service. Store battery pack in
apppliance manual bag when not in use.
Halogen Lights (Optional)
Halogen lights are Optional.
Note: Not offered with 25 in. model.
TO CORD ASSEMBLY 110-120 VAC
WIRE ASSEMBLY
2159-310
TO CORD
ASSEMBLY
110-120 VAC
2326-152
RED
2326-132
BATTERY PACK
RED
BLK
BLK
SPLITTER
2187-198
(OPTIONAL)
2206-299
* MODULE RESET SWITCH
(LOCATED ON SURROUND)
* Reset switch must be installed
and in the "ON" position for
appliance to operate.
FAN 110-120 VAC
GFK-160A
LIGHT WIRE
ASSEMBLY
2532-017
(OPTIONAL)
2326-134
HALOGEN BULBS (X 2)
2201-150
NOT AN OPTION WITH 25 in. MODELS
Need help?
Do you have a question about the SUPREME-I25-IFT and is the answer not in the manual?
Questions and answers