Immergas VICTRIX 26 2 I Manual page 13

Wall-mounted
Hide thumbs Also See for VICTRIX 26 2 I:
Table of Contents

Advertisement

13
ROOm THeRmOsTaT OR RemOTe CONTROL
the boiler is prepared for the application of the Comando Ami-
co Remoto remote control (CAR), which must be connected to
clamps 42 and 43 of the low voltage terminal board, respecting
the polarity and eliminating jumper X40.
Black
ZONES CONTROL
UNIT(Optional)
Storage tank
unit (optional)
KeY:
A4
- Display board
B1
- Flow probe
B2
- DHW probe (optional)
B4
- External probe (optional)
CAR - Comando Amico Remoto remote control
(optional)
E1
- Ignition electrodes
E2
- Detection electrode
E4
- Safety thermostat
E13
- Heat exchanger safety thermal fuse
E14
- Flue safety thermofuse
G2
- Igniter
M1
- Boiler pump
VICTRIX X 12 2 I - X 24 2 I WIRING DIaGRam
Purple
STORAGE TANK
FUNCTION JUMPER
Brown
Blue
Antifreezing
kit
VICTRIX 26 2 I
VICTRIX X 24 -12 2 I
The boiler is prepared for the application of the Room Ther-
mostat (S20) to be connected on clamps 40 and 41 of the low
voltage terminal board, eliminating jumper X40.
Any external probe (B4) must be connected to clamps 38 and
39 always on the low voltage terminal board.
230 VAC 50 HZ
POWER SUPPLY
Orange
Orange
FAN
SPEED
Brown
Blue
ONE
RELAY
Orange
BOARD
Red
(OPTIONAL)
Black
M20 - Fan
M30 - 3-way valve (optional)
R8
- Storage tank resistance
S2
- Selector switch functioning
S40
- System flow switch
S7
- Central heating timer selector switch
S9
- Domestic hot water mode selector switch
S10
- Pump mode selector switch
S13
- Central heating temperature range selector switch
S20
- Room thermostat (optional)
T2
- Low voltage transformer
U1
- Rectifier inside the gas valve connector
X40 - Room thermostat jumper
Y1
- Gas valve
13