Summary of Contents for Progressive Dynamics PD5200
Page 1
Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch PD52 PD52S & PD52DCS PD53-100 Note: The PD52S & PD52DCS are provided with LED lights. The GREEN LIGHTS indicate Shore Power or Generator Power is available. RED LIGHTS indicate a catastrophic event has occurred and the surge protection is no longer function- ing.
Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal use and service,) the product shall be shipped postage prepaid to Progressive Dynamics, Inc. together with proof of purchase. The product will be re- paired or replaced and returned postage prepaid to 507 Industrial Road, Marshall, MI 49068.
Description of Operation When power is applied to the shore side, the contactor activates and supplies power to the panel—GREEN shore LED on front panel will light. When power is applied to the Gen side there is a 20-45 second delay then the Gen side contact will activate, power will go to the panel from the Gen side and the shore side will be locked out—GREEN generator LED on front panel will light.
Page 4
How to Disable Generator Transfer Delay .100 inch Shorting Jumper PD52/PD53 CONTROL BOARD PD52/PD53 CONTROL BOARD With Jumper Installed and delay time disabled To DISABLE the time-out function of the control board INSTALL a .100 inch shorting jumper over the connector marked J1.
SHORE SOURCE VOLTAGE DETECTOR (Used for Auto Gen Start) For Transfer Switches supplied with the optional voltage sense board connect the “16 VAC Out” connec- tions to the “shore power present” inputs of your generator control center. These connections do not have a polarity requirement.
Page 6
One or both RED LEDs on front cover lit. (Units with Surge Protection) 1. This indicates the surge protection on the shore side has been damaged and is no longer functional. 2. Replace circuit board assembly. For model PD52S use PD813347 control Board. For Model PD52DCS use PD813283 control board.
Need help?
Do you have a question about the PD5200 and is the answer not in the manual?
Questions and answers