Page 1
GsmAlarm-420 (V1.05) GSM Alarm and Remote control System FEATURES • Integrated GSM module. • 4 inputs for door, motion, fire sensor connection. • 3 programmable outputs for remote control. • Option to switch the protection mode on/off by short free call.
1.1. SAFETY INSTRUCTION Important! Read and strictly follow all safety and operational instructions written in this user manual, before using GsmAlarm-420 in order to guarantee safety and prevent possible injuries from possible thermal and electric device failures for you and surrounding people.
G E N E R A L D E S C R IP T IO N Remote control and monitoring device GsmAlarm-420 has built-in radio transmitter operating on GSM900 and GSM1800 networks. Do not use the device where it can cause interferences and danger.
SMS with detailed information on the state and the number of activations of each controlled zone. GsmAlarm-420 has 2 (3, if a siren is not used) programmable outputs, intended for remote control of different devices. A user can turn on/off heating, ventilation or lighting systems, etc., via a mobile phone just by typing a relevant code or sending SMS to the control device.
DC Supply O utput Battery (12V or 6V) Input GsmAlarm-420 connection contacts and LED indicators 2.1. INPUTS Z1-Z5 Inputs Z1-Z5 are used to connect sensors of protected zones. The inputs can operate in a “loaded input” mode or in a “zero-one”...
“+” terminal of reserve battery is connected to contact B+. Max capacity of the battery is 1.2 Ah. 12 V battery is used in the premises protection mode. It is recommended to use 6 V battery for car protection. In this case switch GsmAlarm-420 to 6 V mode (see par. 5.3.2 and 6.2).
Blinks at a permanent rate. System is in alarm state, call is made or SMS sent. Blinks twice every 2-3 seconds. ALRNR1 number has not been programmed. In order GsmAlarm-420 could make calls, this number need to be programmed! _________________________________________________________________________________ GsmAlarm-420 Software ver.
Layout of system elements in 7/TRP20 type housing Use double isolated cable 3x0,75 mm for 230V power supply. Circuit breaker or other surge protection device should be installed in the 230V power line. _________________________________________________________________________________ GsmAlarm-420 Software ver. 1.05 - 7 -...
Page 10
The remote control Relay 1 is connected to the terminals C1 and AUX. The gate control system is connected to the relay _________________________________________________________________________________ GsmAlarm-420 Software ver. 1.05 - 8 -...
Mount “GsmAlarm-420” in a way wire connectors are going from the bottom side of the unit. Avoid placing wires adjacent to moving or hot parts of vehicle. Reserve 6V battery must be accurately fixed close to “GsmAlarm-420”...
SIM card is needed for GsmAlarm-420 operation, you may acquire it from any GSM service provider. Before inserting SIM card into GsmAlarm-420 SIM card holder set PIN code request off. It can be performed simply inserting SIM card into any standard mobile phone and following certain phone user manual instructions.
ALRNR1 and corresponding phone number. We recommend enter the number with international code. (E.g. +370..) If GsmAlarm-420 is used for gate control, number of extra user numbers can be as large as fits into the SIM card (up to 250). Any name can be ascribed to user.
A L R N R 1 : + 3 7 0 6 1 2 3 4 5 6 7 8 9 Receipt and decrypting of the SMS by GsmAlarm-420 is confirmed by blink of indicator MODE. The phone, which has sent the programming SMS, immediately receives a confirming SMS with programmed numbers.
Page 15
USER1:+3701234567891 USER2:+3701234567892 USER3:+3701234567893 USR1 – name, assigned to the new number. In order to delete the extra user number, send to GsmAlarm-420 the following message: A A A A A A A A D E L N R : + 3 7 0 1 2 3 4 5 6 7 8 9 1...
SMS with corrected parameters back to GsmAlarm-420. 5.3.1. PROTECTED ZONES Z1-Z5 PARAMETER PROGRAMMING In order to receive SMS with input Z1 – Z5 parameters, send GsmAlarm-420 the following SMS: A A A A A A A A Z P A R A M SMS can be sent from any GSM phone, not necessarily the user’s.
Loaded input mode, 2,2kΩ load Only user ALRNR2. required. Only user ALRNR3. Only user ALRNR4. Only user ALRNR5. Users ALRNR1 and ALRNR2. Users ALRNR1, ALRNR2 and ALRNR3. Users ALRNR1, ALRNR2, ALRNR3 and ALRNR4. _________________________________________________________________________________ GsmAlarm-420 Software ver. 1.05 - 15 -...
A A A A A A A A C P A R A M Reception of the message is confirmed by blinking of the GsmAlarm-420 indicator MODE. The system will send an SMS with the current system and output parameters to the user:...
User is informed with a short call. If during the period of one minute after disarming by call no change in the input state is found, system automatically returns to “armed” mode. _________________________________________________________________________________ GsmAlarm-420 Software ver. 1.05 - 17 -...
PARAMETER U : RESERVE BATTETY VOLTAGE In the case of use of GsmAlarm-420 for car protection, it is recommended to use not 12V, but 6V reserve battery. This will assure reliable charge of reserve battery, independently of the car battery voltage.
5.5. PROGRAMMING OF GATE CONTROL MODE Connect the system after the wiring diagram presented in Chapter 4.1. To program GsmAlarm-420 to operate in the gate protection mode connect it to a power supply and send it the message with the command AAAAAAAA CPARAM (see Ch 5.3.2).
In order to program car mode parameters: return to default settings as already described (connect RESET contacts); send GsmAlarm-420 message AAAAAAAA CPARAM and receive SMS with programmed parameters; change parameter U12 into U06 and send the same SMS to GsmAlarm-420. Input parameters Input Name...
S Y S T E M C O N T R O L SYSTEM CONTROL Five users can fully control GsmAlarm-420: ALRNR1 - ALRNR5. In the case of violation of any area, these users are called in a row. If neither responds, all users are sent SMS with triggered area name and number of triggers.
Speech mode can be activated in two ways: user answers when GsmAlarm-420 calls, or user calls and waits for GsmAlarm-420 to answer (3-4 call signals). In this case relevant parameter F has to be programmed (see Ch. 5.3.2.3), otherwise, after 3-4 calling signals, the arming mode will be switched off and the call will be cancelled.
Page 25
Gate control mode users number programming instructions. DELNR: Gate control mode users number erasing instructions. NRLIST Request to send SMS message (messages) with all numbers stored in SIM card. SMS instructions, for system programming and diagnostics _________________________________________________________________________________ GsmAlarm-420 Software ver. 1.05 - 23 -...
Elektroninės Technologijos”, therefore, company takes no responsibility for GSM network services, coverage and functioning. GsmAlarm-420 system PROVIDED with 24 month warranty. Warranty period starts with purchase date. If there are no purchasing documents, period counted starting from system manufacturing date (dated on security system identification label).