Brief NICE3000 Instruction Manual
7.2 Fault Information and Troubleshooting
If an alarm is reported, the system performs corresponding processing based on the fault
level. You can handle the fault according to the possible causes described in the following
table.
Table 7-2 Fault codes and troubleshooting
Fault
Name
Code
Invert unit
E01
protection
Over-current
E02
during
acceleration
Over-current
E03
during
deceleration
Possible Causes
1. The main circuit
output is grounded or
short circuited.
1. Eliminate external faults.
2. The connecting
2. Install a reactor or an output
cable of the motor is
filter.
too long.
3. Check the air channel and
3. The working
the cooling fan.
temperature is too
4. Contact the agent or
high.
Monarch.
4. The internal
connections become
loose.
1. The main circuit
1. Check whether the RUN
output is grounded or
contactor at the controller
short circuited.
output side is normal.
2. Motor auto-
2. Check whether the power
tuning is performed
cable jacket is damaged,
improperly.
whether the power cable is
3. The load is too
possibly short circuited to
heavy.
ground and whether the cable
4. The encoder signal
is connected reliably.
is incorrect.
3. Check the insulation of motor
5. The UPS running
power terminals, and check
feedback signal is
whether the motor winding is
abnormal.
short-circuited or grounded.
4. Check whether the shorting
1. The main circuit
PMSM stator contactor causes
output is grounded or
controller output short circuit.
short circuited.
5. Check whether motor
2. Motor auto-
parameters comply with the
tuning is performed
nameplate.
improperly.
6. Perform motor auto-tuning
3. The load is too
again.
heavy.
7. Check whether the brake
4. The deceleration
keeps released before the fault
rate is too short.
occurs and whether the brake is
5. The encoder is
stuck mechanically.
seriously interfered
(To be continued)
with.
- 83 -
Troubleshooting
Solution
Level
5
5
5
Need help?
Do you have a question about the NICE3000 and is the answer not in the manual?
Questions and answers
Solusion error 92
How to cheak no nc E 41 error come
@S. Hariharan
Nice 3000 error 21 sub code 106 how to set para in ghar motoh
How to clear E 41 error