Summary of Contents for Viessmann VITOPEND 222 WHSA
Page 1
VIESMANN VITOPEND 222 Gas fired boiler with an integral primary cylinder for open or balanced flue operation 10.5 to 24 (30) kW Datasheet Part numbers and prices: see pricelist VITOPEND 222 Type WHSA Gas fired boiler with an integral primary cylinder Fully automatic With modulating atmospheric burner for open flue opera- tion...
Page 2
Benefits – High draw-off rate, 20 litres per minute & Attractively priced and compact gas fired wall mounted boiler – Modulating primary system with outlet temperature sensor for with integral stainless steel primary cylinder with 50 litres capa- city for the highest DHW convenience – fully fitted constant water temperature &...
Page 3
Selection (cont.) Vitopend 222 Vitopend 100 Vitopend 200 Vitopend 100 Type WHSA Type WHEA Type WHKA Type WH0A Simultaneous operation VIESMANN VITOPEND 222...
Specification - Vitopend 222 Specification Gas fired wall mounted boiler Balanced flue opera- Open flue operation tion Category 2H3P Type 11BS Product ID CE-0085 BP 0399 Rated output range for central heating/DHW heating 10.5-24/30 Rated thermal load 12.1-26.4/33.3 12.4-26.2/33.3 Gas supply pressure Natural gas mbar 20/25...
Specification - Vitopend 222 (cont.) Gas fired wall mounted boiler Balanced flue opera- Open flue operation tion — Required draught coaxial parallel Flue outlet Ø mm 60 / 80 140/150 Ventilation air inlet Ø mm 100 / 125 Note If the gas supply pressure is higher than the maximum permitted value, install a separate gas governor upstream of the system. Balanced flue operation A Area for electrical supply cables HV Heating flow...
Page 7
Specification - Vitopend 222 (cont.) A Area for electrical supply cables HV Heating flow Drain KW Cold water GA Gas connection WW DHW HR Heating return Note For dimensions of on-site pipe connections, see from page 10 Dimensions a (External Ø) –...
Specification - Vitopend 222 (cont.) Open flue operation A Electrical connections HV Heating flow Drain KW Cold water GA Gas connection WW DHW HR Heating return Note For dimensions of on-site pipe connections, see from page 10 VIESMANN VITOPEND 222...
Specification - Vitopend 222 (cont.) Circulation pump Residual head (with integral overflow valve) Pre-installation Clearance for maintenance work Maintain a clearance of 700 mm in front of the Vitopend for main- tenance work. Maintenance clearances to the l.h. or r.h. side of the Vitopend are not required.
Page 10
Pre-installation (cont.) Pre-installation: finished walls Required accessories for installation in unfinished buildings: & Installation template or installation frame incl. fixing parts, valves, gas stop cock and pipe bends. Installation template for finished walls A Installation template GA Gas connection G ¾" B Vitopend position HR Heating return G ¾"...
Page 11
Pre-installation (cont.) Mounting frame for finished walls A Installation template GA Gas connection G ¾" B Vitopend position HR Heating return G ¾" C Area for electrical supply cables. HV Heating flow G ¾" Allow all cables/leads to protrude approx. 1300 mm from the KW Cold water G ½"...
Pre-installation (cont.) Pre-installation: unfinished walls Required accessories for installation in unfinished buildings: & Installation template incl. fixing parts, valves, gas stop cock and pipe bends. Installation template for installation on unfinished walls A Installation template GA Gas connection R ½" B Vitopend position HR Heating return R ¾"...
Page 13
Pre-installation (cont.) Power supply for accessories Allow all cables/leads to protrude approx. 1300 mm from the wall in area B. The power supply of accessories can be connected directly to the control unit. This connection is controlled with the system ON/OFF switch (max.
Vitotronic 100, type HC1 (constant temperature mode) (cont.) & Fault message display Boiler water temperature sensor & Keys: The boiler water temperature sensor is connected to the control – Program selection unit and built into the boiler. – Boiler water temperature –...
Page 17
Connecting cable with RJ11 plug for telephone socket (3.0 m & D1/D2/E‐Plus/O mobile phones long) & & Configuration tool (software for PC) Adaptor RJ11/TAE6N KM BUS cable with plug aVG (3.0 m long) & For accessories and further details, see the Viessmann technical guide "Communication systems" VIESMANN VITOPEND 222...
Accessories for the Vitotronic 100, type HC1 (cont.) On‐site requirements: Specification & RJ11 socket or Rated voltage: 230 V ~ & TAE socket, coding "6N" Rated frequency: 50 Hz Rated current : 15 mA Safety class: Protection: IP 20 to EN 60529; safeguard through appropri- ate design and installation Function:...
Page 19
Vitotronic 200, type HO1 (weather-compensated mode) (cont.) & Demand-dependent heating circuit pump and burner OFF con- Adjusting both heating curves matches the boiler water tempera- trol ture and the flow temperature to these operating conditions. & Adjustment of a variable heating limit Heating curves: &...
Vitotronic 200, type HO1 (weather-compensated mode) (cont.) Specification Protection IP 43 to EN 60529; safeguard through appro- priate design and instal- lation Permissible ambient temperature dur- ing operation, storage and transport -40 to +70 °C Specification Vitotronic 200, type HO1 Rated voltage 230 V~ Electronic control thermostat set-...
Accessories for the Vitotronic 200, type HO1 (cont.) Specification Set room temperature range 10 to 30 °C Power supply via KM BUS adjustable from Power consumption 0.2 W 3 to 23 °C or Protection class 17 to 37 °C Protection IP 30 to EN 60529;...
KM BUS cable with plug aVG (3.0 m long) & Permissible ambient temperature – during operation: For accessories and further details, see the Viessmann technical 0 to +40 °C guide "Communication systems" Installation in living spaces or boiler rooms (standard On‐site requirements:...
Page 23
Accessories for the Vitotronic 200, type HO1 (cont.) Configuration via: Accessories Part no. & Vitosoft 200, type LNR via Optolink Extension of the connecting cable & Vitodata 300 Installation distance 7 to 14 m Data points provided by the heating control unit are hooked up to –...
Runtime for 90 °∢ 120 min & BUS connecting cable (3.0 m long) The mixer motor is mounted directly onto the Viessmann mixer DN 20 to 50 and R ½" to 1¼". Flow temperature sensor (contact sensor) Mixer electronics with mixer motor Secured with a tie.
Accessories for the Vitotronic 200, type HO1 (cont.) Heating circuit pump sÖ & Connecting plug for the heating circuit pump 4(2) A 230 V~ & Mixer motor terminals Mixer motor 0.2(0.1) A 230 V~ & Power supply cable (3.0 m long) Required runtime of the mixer &...
Page 26
Accessories for the Vitotronic 200, type HO1 (cont.) Contact thermostat Part no. 7151 729 Specification May be used as a maximum temperature limiter for underfloor heating systems (only in conjunction with metallic pipes). Lead length 4.2 m, fully wired The temperature limiter is installed into the heating flow and Setting range 30 to 80 °C switches the heating circuit pump OFF if the flow temperature is...
Accessories for the Vitotronic 200, type HO1 (cont.) Internal extension H2 Part no. 7179 144 Specification Electronic PCB for installation into the control unit, in place of the Rated breaking capacity of the integral internal extension H1. relay output 6(3) A 250 V~ An external extractor interlock can be connected with the internal Rated voltage 230 V ~...
Delivered condition Vitopend 222 for open flue operation – Diaphragm expansion vessel & Wall mounted boiler for natural gas and LPG to DVGW Code of – Single stage heating circuit pump Practice G260 [Germany] and EN 437 – Diverter valve with stepper motor &...
Design information (cont.) Flue gas connection The connecting pipe to the chimney should be as short as possi- Nowhere on the Vitopend, except on the flue pipe connection for ble. Therefore, position the Vitopend as closely to the chimney as equipment type B (TRGI), does the surface temperature exceed possible.
Page 30
Design information (cont.) System design The Vitopend is only suitable for pumped hot water heating sys- To minimise distribution losses, we recommend that you size the tems (sealed systems). heat distribution system to a max. flow temperature of 70 °C. The circulation pump is an integral part of the equipment.
Page 31
& Soften fill water with a hardness above 3.0 mol/m , e.g. with the litres/kW, observe VDI 2035 and the technical guide "Standards small softening system for heating water (see the Viessmann for water quality". Vitoset pricelist). Drinking water quality From a water hardness above 3.58 mmol/l and higher, we recom-...
Page 32
Design information (cont.) Sizing the expansion vessel & Panel radiators & System volume approx. 150 litres at average heating water tem- perature 60 °C Calculation Average heating water temperature 60 °C Sizing the expansion vessel = 0.0171 Pressure factor = 150 · 0.0171 = 2.565 litres Exp.
Page 33
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) 1 Boiler flue connection (coaxial) Part no. 7197 742 (order separately) 2 Roof outlet (Ø 60/100 mm) colour black Part no. 7194 831 colour terracotta Part no. 7194 832 3 Fixing clamp (Ø 100 mm) Part no.
Page 34
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) 1 Boiler flue connection bend (coaxial) Part no. 7194 858 (order separately) 2 External wall terminal (Ø 60/100 mm) Part no. 7194 843 (incl. wall bezels) 3 Balanced flue pipe (Ø 60/100 mm) 1 m long (trim to size) Part no.
Page 35
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) The vertical roof outlet has been tested and _-certified as a & Max. extended pipe length: 18 m – 1 x 1 – 2 × 0.5 m = 16 m concentric balanced flue system as one technical unit with the Vitopend.
Page 36
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) 1 Boiler flue connection (parallel) Ø 60/ Part no. 7194 859 100 mm to Ø 80/80 mm (order sepa- rately) 2 Vertical roof outlet (Ø 80 mm) colour black Part no. 7338 658 colour terracotta Part no.
Page 37
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) 1 Boiler flue connection (parallel) Ø 60/ Part no. 7194 859 100 mm to Ø 80/80 mm (order sepa- rately) 2 Bend (Ø 80 mm) 90° Part no. 7198 578 45°...
Page 38
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) 1 Boiler flue connection Ø 80/125 mm Part no. 7198 586 (must be ordered separately) 2 Vertical coaxial roof outlet length 1,22 m (below the roof 0.30 m) with fix- ing clamps colour black Part no.
Page 39
Flue gas/ventilation air system accessories for balanced flue operation... (cont.) External wall terminal 1 Boiler flue connection (coaxial) with Part no. 7198 586 integral condensate trap Ø 80/125 mm (must be ordered separately) 2 External wall terminal (incl. wall Part no. 7198 597 bezels) 3 Protective grille where the flue term- Part no.
Page 40
Flue gas system accessories for open flue operation (aluminium) Flue gas system Ø 140 mm 1 Flue bend with test port 90º (1 piece) Part no. 7189 073 45º (2 pieces) Part no. 7189 074 2 Flue pipe 1 m long (trim to size) Part no.
Flue gas system accessories for open flue operation (aluminium) (cont.) & Combustion ventilation through apertures leading outside Min. room volume: per 1 kW rated output & Combustion air aperture (to the outside): 1 × 150 cm 2 × 75 cm unobstructed cross-section &...
Need help?