Index SAFETY GENERAL INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE ........p. 2 DECLARATION OF CONFORMITY ......................p. 3 WARNINGS FOR THE INSTALLER ......................p. 3 1. DIMENSIONS ............................ p. 4 2. TECHNICAL SPECIFICATIONS ......................p. 4 3. TOOLS, MATERIALS AND ELECTRIC PREPARATIONS ................ p. 4 4.
Children must not handle the automated system and must always be under surveillance. •If the power cable of the D700HS operator is damaged, it must be replaced by skilled personnel with a new cable of the same type. Do not use different power cables.
18) For maintenance, strictly use original parts by FAAC. 6) FAAC declines all liability caused by improper use or use other than that for which the automated system was intended. 19) Do not in any way modify the components of the automated system.
1. DIMENSIONS - Separate low-voltage cable and 230V~ power cables in For the dimensions of the FAAC D700HS operator, consult Fig. 3 different tubes. and Chapter 2: Technical Specifications. - Prepare the electrical system in compliance with the instructions given in chapter “Warnings for the installer”.
5. PRELIMINARY CHECKS 6.3. External release (optional) - The door structure must be suitable for being automated. In If the installation of an external release system is foreseen, you particular make sure that the door dimensions correspond to must lay the small cable before starting with the installation: those indicated in the technical specifications and that the 1) Release the carriage (see par.
8. E700HS CONTROL BOARD 7.2. Fitting on the door 1) Assemble the fitting with the carriage rod (Fig. 17). Place 8.1. Technical specifications and components the fitting on the door in order that the through hole of the release cable is directed toward the left side of the door 230 / 50 Voltage power supply (V ~ / Hz.) (ref.
8.2. Terminal boards and connectors 8.4. Operating logics Logic A (automatic) Description Connected device Status Open (pulse) Stop Control device with NO contact OPEN A (see chapter OPERATING LOGICS) Opens and closes CLOSED No effect (2) No effect again after pause time Device with NC contact, that causes the block of the STOP automated system...
If the procedure is not completed correctly (i.e. due to excessive - The D700HS operator has a cable with two-pole plug for the friction during door movement), the board signals the fault status 230 Vac power supply.
If the learning procedure has ended successfully, the SET UP LED During these 5 seconds, in order to decrease the load on the (Fig. 43 ref. ) stops flashing and stays ON for 5 seconds. release system, you can send OPEN pulses (Fig. 51 ref. ) within During these 5 seconds, in order to decrease the load on the 2 seconds from each other to move back the carriage.
- Release both push-buttons. 12. MEMORY STORING THE RADIOCONTROL CODE - Press the memory stored push-button and hold it down (the LED of the radio control lights up with steady beam). The control unit has an integrated two-channel decoding - Put the radio controls close to each other and hold down system (DS, SLH, LC), named OMNIDEC.
Check every month the efficiency of the anti-crushing device and make sure that it is able to detect a 50 mm high obstacle on the ground. . REPAIRS For repairs, contact authorized FAAC Repair Centres.
. TROUBLESHOOTING Fault Possible causes Solution W h e n t h e l e a r n i n g p r o c e d u r e The STOP and FSW safety devices are starts, the SET UP LED flashes but the active also during the learning phase.
Page 14
Inserto Immagini - Pictures Collection Inserto Immagini - Pictures Collection Collection de Figure - Cojunto de Imagenes Collection de Figure - Cojunto de Imagenes Photo Kollektion - Fotoverzameling Photo Kollektion - Fotoverzameling 2770/3370/3970/4570 2000/2600/3200/3800...
Page 22
- Do not in any way modify the components of the automated system. - Do not attempt any kind of repair or direct action whatever and contact qualified FAAC personnel only. - At least every six months: arrange a check by qualified personnel of the automated system and the safety devices.
Page 24
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...