fakro ZWMA Programming And Usage Instructions

fakro ZWMA Programming And Usage Instructions

Adaptive module
Hide thumbs Also See for ZWMA:

Advertisement

GB
Programming and usage instructions
Contents
1 Safety rules..........................................................................................................................................................1
2 Description of ZWMA module ..........................................................................................................................3
3 Installation of ZWMA module ...........................................................................................................................4
4 Module programming ........................................................................................................................................5
4.2 Associating device with ZWMA module (ASSOCIATE function)...........................................................7
4.3 Device deleting from ZWMA adaptive module (DELETE function) ........................................................8
4.5 Removing the ZWMA adaptive module from the network.........................................................................9
4.6 Additional functions..................................................................................................................................10
function) ......................................................................................................................................................11
5 Exemplary configuration of electrical accessories with the ZWMA module...................................................12
6 Technical parameters.........................................................................................................................................13
7 LED signalling of digital inputs........................................................................................................................13
8 WARRANTY....................................................................................................................................................14
13.11.21 NC825-GB
adaptive module ZWMA
1/16
©2013, FAKRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZWMA and is the answer not in the manual?

Questions and answers

Summary of Contents for fakro ZWMA

  • Page 1: Table Of Contents

    4.6 Additional functions..........................10 4.6.1 Configuring the Z-Wave network using the ZWMA adaptive module (INCLUDE function)..10 4.6.2 Excluding a device from the Z-Wave network using the ZWMA adaptive module (EXCLUDE function) ..............................11 5 Exemplary configuration of electrical accessories with the ZWMA module...........12 6 Technical parameters............................13...
  • Page 2: Safety Rules

    ● Plastic containers used for packing should be kept out of children's reach as thy may be a potential source of hazard. ● The ZWMA module should be used for its intended purpose in agreement with its design. The FAKRO Company shall not be held responsible for any consequences resulting from improper module use.
  • Page 3: Description Of Zwma Module

    2 Description of ZWMA module ZWMA adaptive module fulfils the function of a controller and enables remote control of electrical accessories compatible with Z-Wave system, e.g. ZWS12 and ZWS230 actuators for operating FAKRO roof windows. The module is equipped with four digital inputs, 3-contact (no.3 Figure 1) to which potential-free signals from different external devices are connected, e.g.
  • Page 4: Installation Of Zwma Module

    3 Installation of ZWMA module The ZWMA module should be mounted onto a wall or other permanent element of the building by means of screws driven into cylindrical plugs inserted into openings drilled in the wall. In order to install the ZWMA module, it is necessary to: 1.
  • Page 5: Module Programming

    4 Module programming In order to operate electric FAKRO accessories equipped with the Z-WAVE system by means of the ZWMA adaptive module, it is necessary to: 1. Add the device to be operated by means of the module to the “Z-Wave” system – see ZWP10 remote control and ZWK10, ZWK1 keyboards manuals, chapter “Adding device to the network (INCLUDE...
  • Page 6: Associating Adaptive Module To The Z-Wave Network (Learn Mode Function)

    Figure 3: Associating ZWMA module with Z-Wave network *) Programming error results from failure to receive any reply from the device which can be caused by: failure to enter LEARN MODE in the ZWMA module by pressing the “In/Ex” button three times until •...
  • Page 7: Associating Device With Zwma Module (Associate Function)

    4.2 Associating device with ZWMA module (ASSOCIATE function) Associating a device with the ZWMA module which has been already added to the Z-Wave network enables operating that device by means of a signal sent to the digital input in the module. The procedure of device associating is presented in Figure 4.
  • Page 8: Device Deleting From Zwma Adaptive Module (Delete Function)

    4.3 Device deleting from ZWMA adaptive module (DELETE function) This function removes from the module's memory the device which has been associated with a selected channel. It does not remove the device from the “Z-Wave” network. The procedure of deleting the device from a given channel is presented in Figure 5.
  • Page 9: Return To Default Settings Of The Zwma Adaptive Module (Default Function)

    10 seconds until the error is signalled by the controller or reset it by disconnecting the power supply. Figure 6: Restoring default settings in ZWMA controller 4.5 Removing the ZWMA adaptive module from the network Removing the ZWMA module from the network consists in restoring default settings in this module. 13.11.21 NC825-GB 9/16 ©2013, FAKRO...
  • Page 10: Additional Functions

    (e.g. keyboard ZWK10, ZWK1, ZWP10, ZWPTV). The ZWMA module should be associated with the network as SECONDARY. However, there is a possibility of programming the module for the network as PRIMARY. The procedure of device adding to the network with the use of the ZWMA module is presented in Figure 7. >0,5Sec.
  • Page 11: Excluding A Device From The Z-Wave Network Using The Zwma Adaptive Module

    (e.g. ZWK10, ZWP10, ZWPTV). If the ZWMA module in the Z-Wave network is marked as PRIMARY (network configuration as per section 4.6.1), then devices can be excluded only using that module. The procedure of device excluding from the network with the use of the ZWMA module is presented in Figure 8. >0,5Sec.
  • Page 12: Exemplary Configuration Of Electrical Accessories With The Zwma Module

    Blinds were connected to 15VDC (5) power supply and with the use of Primary (6) controller added to the Z-Wave network. In order to control the blind with the switch (4), also ZWMA module (1) was added to the same Z-Wave network with the use of LEARN MODE function (see section 4.1 of the manual) as a Secondary controller.
  • Page 13: Technical Parameters

    – ▲ lights at short-circuit of the contact responsible for sending command open – ▼ lights at short-circuit of the contact responsible for sending command close – ▼▲ light at short-circuits of the contacts responsible for sending command stop COM 2, COM 3 and COM 4 analogously 13.11.21 NC825-GB 13/16 ©2013, FAKRO...
  • Page 14: Warranty

    In case of failure, the device must be submitted for repair with a Warranty Card. Defects revealed within the warranty period will be removed free of charge no longer than 14 days after accepting the product for repair. Warranty and post-warranty repairs are performed by the manufacturer i.e. FAKRO PP. Sp. z o.o. Quality certificate: Device Model............................
  • Page 15 13.11.21 NC825-GB 15/16 ©2013, FAKRO...
  • Page 16 FAKRO PP Sp. z o.o. ul. Węgierska 144A 33-300 Nowy Sącz Polska www.fakro.com tel. +48 18 444 0 444 fax. +48 18 444 0 333 13.11.21 NC825-GB 16/16 ©2013, FAKRO...

Table of Contents