CL7206A5 RFID Reader module User manual Shenzhen Hopeland Technologies Co., Ltd Welcome to be the user of Hopeland RFID products. ThanksforchoosingHopelandRFID’sMulti-functional...
Page 2
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Page 3
Address: 17/F, Block A, Clou Bldg, Baoshen Road, Hitech Industrial Park North, Nanshan District,518007, Shenzhen, China Hereby, SHENZHEN HOPELAND TECHNOLOGIES CO., LTD. declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU...
Catalogue 1. SPECIFICATION ....................................6 ....................................6 RODUCT FEATURES ............................6 AIN FUNCTIONS AND TECHNICAL FEATURES 1.2.1 Main functions ..................................6 1.2.2 Features ..................................... 6 1.2.3 Working environment ................................6 2. EXTERNAL INTERFACE ..................................8 ........................................8 ..................................8 NTERFACE PHOTOGRAPH ..................................
Page 5
4.4.1.2 Network port communication connection ....................4.4.1.3 RS485 communication connection ..........................15 ..................................15 4.4.2 ATA DISPLAY AREA EPC ....................................16 4.4.2.1 EAD TID ..................................... 17 4.4.2.2 EAD 4.4.2.3 Custom read ................................... 17 4.4.2.4 Stop read ..................................18 4.4.3 Write data ....................................18 4.4.3.1 Write EPC data ................................18 4.4.3.2 Write user data ................................
1. Specification 1.1 Product features CL7206A5 is a UHF RFID reader module, partner with CL7206D2. 1.2 Main functions and technical features 1.2.1 Main functions Hardware partner with CL7206D2 Telecommunication port: RS232, RS485, Enternet port, USB IO interface: 1 for IO input, 2 for IO output, 1 for wiegand output, IO out and wiegand is same port. IO interface’s level fluctuation trigger the reading function(Response time: <10ms) Power by adapter and USB 1.2.2 Features Internet port speed rate: 10M/100M automatic. ...
2. External interface 2.1 Size 105mm×95mm×18mm (excluding accessories) 2.2 Interface photograph Development board can be compatible with CL7206D2 2 port module. Development board power up through power port, and communicate with USB/RS232/Network port. ...
2.3 Interface Definition RJ45 Interface Definition form Linear Color Definition 1 White, green Ethernet data transmitting positive end 2 green Ethernet data transmitting negative end 3 White, orange Ethernet data receiving positive end 4 Blue 5V power input 5 White, blue Power ground 6 Orange Ethernet data receiving negative end 7 White, brown RS485 positive 8 Brown RS485 negative RS232 Interface Definition form Linear Definition 1 NC 2 RXD 3 ...
3. Installation manual 3.1 Attentions To ensure the normal and stable operation of the device and your personal property and safety, please carefully read the following notes before install CL7206A5 module: 1. Firstly, check whether the power socket is connected to the ground, and to see whether the local power supply voltage is in accordance with the applicable voltage range of the reader; 2. Check the device and the external connection if is closely connected; 3. Pay attention to the type selection and the length limit of the cable and the serial line: Serial line connect directly, no longer than 5 meters RS485 Cable connect directly, no longer than 80 meters ...
☆ Insert the power cord into the AC power supply socket and plug another end into the power connector of the device and tighten. ☆ Turn on and wait about 20 seconds, the system initialization process is completed and is standby state. 3.3.2 Connect PC ☆ Development board comes with RS232, network port, USB port, RS485 port. ☆ RS232 and USB interface is for short distance communication (less than 5m), through the DB9 connector and the PC serial port connection to realize the communication of PC and the device. ...
4. Operation instructions 4.1 Demo software instructions Demo software for CL7206A5 is mainly used for system control, communication model, configuration setting and inquiring, reading tags and data displaying etc. 4.2 Demo software application environment Software environment Windows 2000 Service Pack 3, Windows Server 2003, Windows XP Service Pack 2, Windows 7 OS Hardware environment PC with P4/1.7GHz above,512M or above, 40G hardware 4.3 Demo software version Demo V1.0.4 4.4 Demo software operation 4.4.1 Connect to reader All functions are available only after connected successfully 4.4.1.1 Serial communication connection After connected the reader with power and communication cable (serial port or network cable), open the demo software, if the icons on main Manu are grey, means the reader is not connected. In the ‘connecting reader’ option list select communication mode ‘serial connection’, ‘connection parameters’ select ‘COM?’ ...
Page 13
button, as shown in image 4‐1. Image 4‐1 Serial communication connection If the connection is successful, all the icons in the toolbar are illuminated, as shown in image 4‐2, means the serial communication connection is successful. ...
4.4.1.2 Network port communication connection Network port used for long distance connection (within 80 m), connect to the router through cable and switcher, or connected with the PC network port directly. Select the communication mode "TCP connection" in the "connect reader" option list, "connect parameter" input reader IP (default 192.168.1.116), enter the communication port number (default 9090), and click OK button, as shown in image 4‐3 ...
image 4‐4. Reader setting 4.4.1.3 RS485 communication connection Select the communication mode in the "connect to the reader" option "485 connection (serial port)", "connect parameter" select "COM?" (select PC serial number), communication rate select "115200", enter the RS485 address, then click OK, as shown in image 4‐5 ...
Image 4‐6 Data display area parameter meanings Type: Tags type: 6C EPC: Tags’ EPC data, read and writable TID: the TID data of the label, the only logo, read only User Data: user data area can be read and write. Reserve Data: reserved area data, store the password data, etc. Total Count: total number of tags ANT1: the reading times of NO.1 antenna RSSI:Signal Intensity 4.4.2.1 Read EPC Click the button , the data display area will display the current read EPC data, the most length for the EPC is 240 bits. EPC display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4 hexadecimal character) If you want to read the EPC data of the custom length, please refer to chapter ...
4.4.2.3 custom read 4.4.2.2 Read TID Click the button , the data display area will display the current read EPC and TID data TID data display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4 hexadecimal character). TID length, the default is 6 words. If you want to read the TID data of the custom length, please refer to chapter 4.4.2.3 custom read ...
Matching read, you can matching read through known EPC data or TID data of tags. Read TID, select to read the tag TID data, the read mode default as "adaptation", use the word as length unit. Read the user area, select to read the tag user area data, use the word as the starting address and read length unit Read the reserved area, select to read the tag retains data, use the word as the starting address and read length unit. Image 4‐8 6B tag setting 4.4.2.4 Stop read ...
Image 4‐9 Write EPC data Select a label data (contains TID information) has been read, fill in the EPC data (16 hex string), click "OK". 4.4.3.2 Write user data Click button and pop up dialog box as shown in image 4‐10: ...
Image 4‐10 write user data Select a label data (contains TID information)has been read, fill in the user data (16 hex string), click "OK". 4.4.3.3 Custom tag action Click button and pop up dialog box as shown in image 4‐11: Image 4‐11 Custom tag action 1. Select a tag data that has been read; 2. Click the "custom operation" button; 3. Take detailed action to write / lock / destroy tag according to the reader protocol 4.4.4 TCP server / client mode Select configuration on the main demo interface > "read and write configuration >" TCP server / client mode ", pop‐up dialog box, as shown in Image 4‐12: ...
Image 4‐12 Mode setting 4.4.6 Frequency hopping management Click “configuration” on the main interface > RFID configuration > "hopping management", pop‐up frequency hopping management dialog box, as shown in image 4‐13 management Image 4‐13 Frequency hopping Select " GB,920‐925MHz " (see Image 4‐14) in the "working band" drop‐down list, click the "Settings", select single frequency points from the left frequency list box(see ...
Image 4‐14) then click the " " button, right into the list box, and then click the "configuration" to confirm; If you want to select the full band frequency hopping just click all the frequency points will show on the right side of the list box, click the "configuration" to confirm. If you click , all frequency points on the right side of the list box will be cleared. Image 4‐15 hopping selection Note:The purpose of setting up the "automatic" is to avoid the interference of ...
filtering Image 4‐15 Label Filtering time: indicates that the same label content within a specified period of time within a read card instruction is only uploaded once, 0~65535, and time units: 10ms. RSSI threshold: When label RSSI value small than the threshold value, the label data will not be ...
4.4.9 GPI/O Configuration GPI/O control to provide the query and set up the I/O port state, control the function of the I/O device. GPI configuration Select “configuration “on the main interface > "GPI/O configuration" > “GPI configuration "then pop‐up dialog box, as shown in image 4‐17: Image 4‐17 GPI configuration ...
image 4‐18 GPO configuration CL7206A5 development board only supports two GPO outputs, that is "1" and "2". Select the high / low level, click this configuration to execute settings after modify. 4.4.10. Advanced configuration Weigand configuration Select “configuration” on the main interface > "GPI/O configuration" > “Weigand "then pop‐up dialog box, as shown in image 4‐19: ...
Weigand port Parameter configuration: includes “Weigand 26, “Weigand 34" and “Weigand 66"models. Weigand 26: TID or EPC data reported from the end of the Weigand port is valid for 3 bytes. Weigand 34: TID or EPC data reported from the end of the Weigand port is valid for 4 bytes. Weigand 66: TID data reported from the end of the Weigand port is valid for 8 bytes. Restore factory settings Select “configuration” on the main interface > “restore factory settings” then pop‐up dialog box, as shown in image 4‐20: ...
Page 27
Image 4-21 Data export Read the tag data to support data export, export format can be.Csv (comma file) and.Xls (Excel). Software upgrade The reader support for online upgrade, software upgrades support the baseband software upgrade (the underlying software) and application software upgrades (system software applications). Select "tools" on the main interface >...
Page 28
progress bar shows 100% that means the application software upgrade successfully, pop-up upgrade prompted success dialog box, click OK to restart the reader, as shown in image 4-23. Image 4-23 Software upgrade successfully The process of the application of the base band software is the same as that of the application software.
5. Common failures 5.1 Daily maintenance The routine maintenance of CL7206C usage: ☆To check whether the tightening of RF connector ☆To check if the screw fixed reader and antenna is loose ☆To check whether the RF cable joints appear outsourcing breaking the shielding layer ☆To check if the reader power line connection is reliable 5.2 Common failure analysis and solution Power supply system failures:...
Page 30
Check if the setting of antenna number is correct Check if the label is damaged Check if the label is placed in the reader's valid reading and writing range. Check if the electromagnetic interference between the reader and the other device. For the problem users cannot solve, please contact customer service.
5 RS232 serial port cable 1 pcs standard 8 2035100000003 6 USB port cable 1 pcs standard 6 2035020000021 7 Feeding Cable 1 pcs Standard 21 6.2 Storage environment CL7206A5 fixed reader should be stored in below conditions: ☆ Environment temperature:-40℃~+85℃ ☆ Relative humidity:5% RH~95%RH...
7. Host Information The host will Satisfy Class I or Class II permissive change based this module FCC Product: Module housing Model: HL7206B7 The Picture...