USER MANUAL CIRCLE FLAMER X-F1800 V1.2 Showven Technologies Co.,Ltd.
Page 2
Operate according to instructions is very important for safety, and can elongate the service life of the machine. Strictly follow the instruction in the manual when operate Circle flamer X-F1800. If you have any doubts, please contact SHOWVEN technologies Co., Ltd by info@showven.cn.
Disclaimers: SHOWVEN technologies Co., Ltd excludes liability for unsafe situations, accidents and damages resulting from: 1. Ignoring warnings or regulations as shown on circle flamer or this manual. 2. Use for other applications or circumstances other than those indicated herein.
Page 4
▲Structure of Circle Flamer 1. Handle 2. Firing Nozzle 3. Top Panel 4. Fuel Bottle Area 5. Control Panel 6. Safety Loop • Connection dimension diagram of bottom bracket of the flamer 203.5 ▲Overview of Control Panel 1. LCD screen operate panel 2.
Page 5
▲Operation Panel 1. LED Display Area RX: Radio receiving (reserved); DMX: DMX signal. Flash means DMX signal available, otherwise no DMX signal; ERR: Light on when there is an error; PUMP: Light on when pump is running. 2. Button Funtions: MENU: Switch interface to setup parameter;...
Page 6
5. Alert Message Alert Message Explanation E0 System Lock Safety lock located at TEST MODE. Pressuriser for about 13s, pressure value failed to reach 100%, system will report E1. E1 Pressure Err Possible fault: No fuel, pump failure, pipeline problem etc. Pipeline can't release pressure leads to pressure relief error.
Page 7
7. Advanced Interface Press “MENU” 3s enter advanced interface, press “MENU” to switch interface, press “MENU” 3s can back to main interface. Items Contents Description OFF / Motor/ Pump / Igniter / Relief Valve / Jet Valve 1. Motor Swiveling and stop at target angle. Pump running 1s, if pressure reached the 2.
Page 8
(1) 1 to 15 is the firing angle of circle flamer, Far Right is position 15, Middle is position 8, Far Left is position 1. (2) Audience side and control side are indicated in above picture. (3) Safety distances for CIRCLE FLAMER are indicated in above picture. At least 15m in all projection directions, at least 5m to the other sides of the device.
Page 9
CIRCLE FLAMER occupy 6 channels. Set DMX Address Detail information please refer to the table of 6. Set DMX address page18. Host controller: Press”pre-heat” button (light on). 7. Pressuriser DMX console: switch DMX value of channel 6 to 50-200. Reconfirm safety lock located at TEST MODE before test.
Page 10
14. Switch safety lock Guarantee safety use for next time. to TEST MODE Power off CIRCLE FLAMER, tear down power cable 15. Power off and DMX cable, pack up the device when it is cooled down. 3. Firing Angles The firing angle for CIRCLE FLAMER is ±105°, from the Audience Side view, there are altogether 15 firing angles as below. NO.8 (...
Page 11
4. Drive time for Effects Time needed for the motor drive from NO.8 to relevant angle. Angle Drive time needed NO.1 -105° 170ms NO.2 -90° 150ms NO.3 -75° 130ms NO.4 -60° 110ms NO.5 90ms -45° NO.6 -30° 70ms NO.7 -15° 50ms NO.8 0°...
Page 12
5. Control of Circle Flamer Circle Flamer X-F1800 has 70 preset sequences, you can use related channel and sequence No. to access certain sequence. Below, you can find sequence list and single ignitions. Single Ignition Sequence List CH5 DMX Sequence...
Page 13
Step Sequences List CH5 DMX Nozzle Firing Duration Ignition angle NO. Description Reference Movement (For reference) Value Step from 1-15 SHORT flame Step sequence L->R 2.57s 80-81 Step from 15-1 SHORT flame Step sequence R->L 2.57s 82-84 Step 5>8>11 SHORT flame Step sequence L->R 1.00s 85-86...
Page 14
Additional Sequences List Nozzle Firing Duration CH5 DMX Ignition Description Movement (For reference) Reference Value angle NO. Step 2>14 SHORT flame Step sequence L->R 0.60s 161-163 Step 14>2 SHORT flame Step sequence R->L 0.60s 164-165 Step 2>14 LONG flame Step sequence L->R 1.38s 166-168...
Page 15
• Channel Explanation 1. The first channel controls the firing angle. It defines to which angle the nozzle of CIRCLE FLAMER move to. The angle can be chosen anywhere between -105° to +105° (DMX value 0 to 255). 2. The DMX value for angle of 0° is 127.5 (round up 128). Use this value, following formula can be used to calculate all other angles ∠...
Page 16
> Channel 6 (CH6): Firing Pressure Setup The sixth channel can set the working mode of pump. When the safety lock located at TEST MODE, set DMX value between 50-200 to test the system. For safety, the pump will not working. When the safety lock located at USER MODE, the pump can be activated by set DMX value between 50-200.
Page 17
7. Operating with SHOWVEN host controller ZK6200/ZK6300 1) Hardware description MODEL ZK6200 Dimension 390×300×110mm Weight 3.5kg Input 110-240Vac, 50/60Hz Work power Work Temp. -10℃~ 50 ℃ Interface 2*CAN port 2* media port (music trigger) 2*MIDI port (music trigger) 1* DMX512 input 1*DMX512 output.
Page 18
a) Cable Connection Area AC Input: AC Power Input; CAN: CAN communication input/output; MIDI In: Midi time synchronous signal input; DMX 512: DMX signal input/output; LAN: network interface; USB: program download interface, SparkularEdit200 software port. b) Manual firing operation region c) Mode Selection Area There are 5 standard dynamic mode and 1 special effects mode.
Page 19
Set circle flamer DMX address as below: CIRCLE FLAMER No. DMX Address Note: wrong DMX address setup may leads to circle flamer out of control. Setup of Host controller: 1. Press “F3” enter host controller configuration menu, DEVICE choose “CIRCLE FLAMER” as below. 2.
Page 20
4. In order to lubricate the pipeline and pump it is highly recommended to add 10-20ml castor oil per 10L canister. 5. Software can be upgraded with download cable from SHOWVEN. 6. Switchable power input design, switchable between 110V and 220V as show below (voltage will show on it).
Page 21
Warranty Instructions ▲Sincere thanks for your choosing Circle Flamer X-F1800, you will receive quality service from us. ▲The product warranty period is one year. If there are any quality problems within 7 days after ship ping out from our factory, we can exchange a brand new same model machine for you.