Watts 500800 Installation And Operation Manual

Watts 500800 Installation And Operation Manual

Hot water recirculation system

Advertisement

Installation and Operation
Manual
Hot Water Recirculation System
Model 500800
WARNING
!
This Hot Water Recirculation System does not work with
Tankless water heaters.
For Indoor Use Only.
Please understand this is not an anti-scald device. You
may have some warm water in your cold water line under
the sink where the valve is installed. Once the cold water
line is opened, the warm water will dissipate in a very
short time.
WARNING
!
Read this Manual BEFORE proceeding with
installation.
Failure to read and follow attached instructions or
operating parameters may lead to the product's
failure and possible damage to property. Refer to
enclosed warranty for operating parameters to
ensure proper use with your water supply.
Keep this Manual for future reference.
Pump and Comfort Valve CS VW
MH26400 65GM
ANSI/NSF 61
Drinking Water System Components
Maximum use temperature: 140°F
Mfg. by Grundfos Pumps
12" Supply Line and Adapters
ANSI/NSF 61
STD. 61
LISTED

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Before Installation
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operational Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation
Pump Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3/8" Sensor Valve Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1/2" Sensor Valve Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Check Sensor Valve Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parallel Sensor Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation
Setting Up The Timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Manual Switch Mode Of Operations . . . . . . . . . . . . . . . . . . . . . . 5
Timer Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical and Warranty Information
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
IOM-WQ-500800
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 500800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts 500800

  • Page 1: Table Of Contents

    IOM-WQ-500800 Installation and Operation Manual Hot Water Recirculation System Model 500800 WARNING This Hot Water Recirculation System does not work with Tankless water heaters. For Indoor Use Only. Please understand this is not an anti-scald device. You may have some warm water in your cold water line under the sink where the valve is installed.
  • Page 2: Introduction

    Introduction WATER HEATER CHECKLIST Electric Water Heater Thank you for your purchase of the Watts Hot Water Recircu- lation System. This system has been inspected and tested prior • Turn off Power to your Water Heater at the breaker box.
  • Page 3: 3/8" Sensor Valve Installation

    If your home has a branched hot water line, more than one Sensor Valve may be necessary. Additional Sensor Valve kits can be found at some retail locations as well as the Watts website www.PremierH2O.com or by calling us toll free at 1-800-752-5582.
  • Page 4: 1/2" Sensor Valve Installation

    STEP 2.1 1/2" Stop Valve Installation Check Sensor Valve Operation Step A – Close both the hot and cold water stop valves below the After installing the pump and the sensor valve, verify the valve is sink. functioning properly by following the steps below:Step 2.1 Step B –...
  • Page 5: Setting Up The Timer

    Turn the programing ring until 1:00 AM is aligned with the triangle on the inner dial. The timer control is designed only for use with the specified WATTS Step B - Plug the line cord from the pump into a properly grounded INSTANT HOT WATER RECIRCULATING SYSTEM.
  • Page 6: Troubleshooting

    Troubleshooting PROBLEM CAUSE SOLUTION 1. Long wait times for hot water? Pump does not have power Check the power supply to the pump as well as the timer settings. Troubleshooting Pump related issues If there was a power outage, the timer does not reset and will require you to manually reset the timer.
  • Page 7 If this Manual are misplaced, damaged or illegible, or if you require additional copies, please contact Watts for these items at no charge. If you are ever uncertain about a particular task or the proper method of operating this system, consult this Manual or contact a Premier Technical Support Representative at 1-800-752-5582.
  • Page 8: Limited Warranty

    Include a note stating the problem experienced and include your name, address and your return authorization number. No returns will be accepted without the proper return authorization number. Watts will repair it or, at Watt’s option, replace and ship it back to you prepaid.