5
Configuration
5.2.1.3
Configuration with 1 wheel sensor RSR110-001 or 1 wheel sensor
RSR110-002
DIP-no.
DIP-switches
1
2
Table 5.4: Configuration with 1 wheel sensor RSR110-001 or 1 wheel sensor RSR110-002
Further information regarding the interfaces and the pin assignment can be found in chapter "Wir-
ing of the Wheel sensor Signal Converter WSC".
5.2.2
Configuration of the normal status of all optocoupler outputs
The normal status of the optocoupler outputs is given under the following conditions:
•
wheel sensor mounted correctly
•
wheel sensor adjusted correctly
•
wheel sensor not damped
•
no error
The normal status of the optocoupler outputs can be configured as follows:
DIP-no.
DIP-switches
3
3
Table 5.5: Configuration of the normal status of all optocoupler outputs
Classified
Setting
Output
ON
It is recommended to use this configuration with 1 wheel sensor
RSR110-002.
ON
If this configuration is used with 1 wheel sensor RSR110-001,
then it is recommended to connect only 1 sensor system of the
wheel sensor.
1 system output, which is output twice:
•
if 1 wheel sensor RSR110-001 is used,
then the status of the connected sensor system is output at
interface "optocoupler output 1 and 2" at OUT1+, OUT1-,
OUT2+ and OUT2-
•
if 1 wheel sensor RSR110-002 is used,
then the status of the sensor system is output at interface
"optocoupler output 1 and 2" at OUT1+, OUT1-, OUT2+ and
OUT2-
1 error output, which is output twice (normal status = closed):
•
the error is output at interface "optocoupler output 3 and 4" at
OUT3+, OUT3-, OUT4+ and OUT4-
Setting
Configuration
OFF
closed in normal status (recommended setting)
ON
open in normal status
Technical documentation Wheel sensor Signal Converter WSC001
© 2017 by Frauscher Sensortechnik GmbH – Austria
D4586-1
EN
- 31 -