Installation/Care/Use Manual
Retrofit Hydroboost Bottle Filling Station
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER
COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
INSTALLER
HTHB-HAC Bottle Fillers are among the easiest to install on the market today. To
insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL,
AND OTHER APPLICABLE CODES. After installation, leave these instructions with
the Fountain for future reference.
HAC-HB*1B HAC-HB-NF-*1B
| 855-558-9600 | BottleFillingStations.com
HTHB-HAC
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4" WRENCH OR CRECENT
WRENCH
UTILITY KNIFE
TAPE MEASURE
PENCIL
5/32" ALLEN WRENCH
Page 1
IMPORTANT
1000001732 (Rev. D - 06/16)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HTHB-HAC and is the answer not in the manual?

Questions and answers

Summary of Contents for Halsey Taylor HTHB-HAC

  • Page 1 COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). INSTALLER HTHB-HAC Bottle Fillers are among the easiest to install on the market today. To insure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
  • Page 2 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com WATER COOLER PREPARATION NOTE: • On Two Level Models, the Bottle Filling Unit MUST be mounted on the higher unit: • Two Level Standard Models; high unit is on Left Hand(LH) side. •...
  • Page 3 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com WATER COOLER PREPARATION 4) Remove Bubbler Water Line • Disconnect water line from bubbler. Remove Bubbler Water Line 5) Lift and Remove Basin. • Remove basin assembly by lifting straight up, disconnecting the drain line from the P-trap.
  • Page 4 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com HWF3000 WATERSENTRY PLUS FILTER INSTALLATION WARNINGS: • Do not use with water that is microbiologically unsafe or of unknown quality. For potable water only. • Do not use with a hot water supply. Rated for water temperature: 33°-100°F(2°-38°C) •...
  • Page 5 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com HWF3000 WATERSENTRY PLUS FILTER INSTALLATION 3) Mount Filter Head Assembly Mount Filter Head Assembly into Cooler. Unit with single supplied screw: • Single Level Models • Mount on inside of left panel butted up against top lip.
  • Page 6 RE-PLUMBING SINGLE STATION WATER CIRCUITS (NON-FILTER) CAUTION: • This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 7 RE-PLUMBING SINGLE STATION WATER CIRCUITS (WITH FILTER) CAUTION: • This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 8 RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (NON-FILTER) CAUTION: • This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 9 RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (WITH FILTER) CAUTION: • This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly! • When disconnecting water lines use a container to catch any water running out of the lines.
  • Page 10 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com BASIN ASSEMBLY PREPARATION 1) Connect Water Line • Connect water line from Regulator to Bubbler. Connect Water Line 2) Install New Basin Assembly • Reposition Basin Assembly (Basin with Drain and Bubbler hardware) back onto the cooler.
  • Page 11 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com BOTTLE FILLER GASKET Fig. 6 Fig. 7 Page 11 1000001732 (Rev. D - 06/16)
  • Page 12 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com BOTTLE FILLER INSTALLATION 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL TOP COVER SCREWS WALL UNIT CENTER LINE MOUNTING PLATE BOTTLE FILLING UNIT Fig. 8 Fig. 9 Fig. 10 BOTTLE FILLER INSTALLATION 1) Remove two (2) mounting screws with 5/32”...
  • Page 13 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 14 HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com RESET FIVE PIN BUTTON CONNECTOR FOUR PIN PIGGY BACK MAIN BOARD CONNECTOR TERMINAL ON POWERCORD WHITE I.R. BOARD SOLENOID LED BOARD VIOLET YELLOW PROTECTIVE GREEN GROUND (NOT USED) CONNECTOR NEUTRAL FROM POWER WHITE CORD RIBBED...
  • Page 15: Replacement Part Kits

    HAC-HB*1B HAC-HB-NF-*1B Buy at | 855-558-9600 | BottleFillingStations.com REPLACEMENT PART KITS PART NO. DESCRIPTION Kit - Electrical Package 115V 98543C Kit - IR Sensor 115V & 220V 98544C Kit - Solenoid Valve Replacement 115V 98545C Kit - Aerator Replacement 98546C Kit - Top Cover Replacement 98666C Kit - Hardware &...

This manual is also suitable for:

Hthb-hac seriesHac-hb 1b seriesHac-hb-nf 1b series