Download Print this page

EVERSPRING ES160 Manual

Z-wave plus outdoor pir motion detector module

Advertisement

Quick Links

Z-wave
ES160
The ES160 is a PIR module to retrofit onto existing outdoor floodlight. It features a
PIR detector to detect motion through movement of heat sources and a lux sensor
for determining brightness of its surroundings. It is equipped with Z-wave
wireless communication capability to upgrade the ordinary outdoor floodlight into a
smart home device.
When not connected to a Z-wave network, ES160 when fitted on a floodlight is
fully operational as a standalone security floodlight. During hours of darkness its
PIR detector turns on the floodlight when it detects movement in the protected
area. Its built-in timer will then turn off the floodlight after a preset time has elapsed.
During daylight hours, its lux sensor saves energy by deactivating the motion
sensor and the floodlight. The lux level and the timer can be set through knobs on
the device itself.
When added into a Z-wave network, ES160 communicates directly with other end
devices such as smart plugs, or to report directly to a Z-wave controller (usually a
gateway). It alerts the controller when motion is detected and through Z-wave
commands, the controller can remotely turn on/off the floodlight at any time and be
able to configure its lux level and timer setting.
This product supports the S2 security protocol that uses encrypted Z-Wave
messages to communicate to other security-enabled Z-Wave
plus
security-enabled Z-Wave
Controller must be used in order to fully utilize the
security features of this product.
ES160 can be installed on standard external outdoor lighting fixture without a
motion sensor, or to replace existing motion sensor on security floodlights.
Product Overview
 PIR Lens
 LED indicator (hidden behind lens)
 Link button
plus
outdoor PIR motion
detector module
plus
 Lux knob
 Timer Knob
 Threaded arm
Below diagram show a typical assembly of ES160 onto a floodlight fixture (fixture
is not included).
plus
(Wall mount)
Note: Please read this entire instruction manual before you start the installation.
IMPORTANT
Installation must be performed by skilled technicians who are informed
about the standards and technical requirements of the appliance and its
proper installation.
Check your local codes as they apply to your situation. If the house wiring is of
aluminum, consult with an electrician about proper wiring methods.
plus
products. A
Before proceeding with the installation, TURN OFF THE POWER TO THE
LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID
ELECTRICAL SHOCK.
SAFETY PRECAUTION
DO NOT install when it is raining.
Isolate the power supply before installation.
Ensure that local Wiring and Building regulations are complied with.
The unit is supplied with a pre-wired supply cable this must be used and must
not be removed.
Total lighting load to ES160 not exceed:
- 300W incandescent @ AC120V
- 100W LED @ AC120V with 0.8 pF Driver
Installation & Wiring instructions
Note : As with any outdoor installation work it is always recommended to start
early during the day.
1
(Under Eave mounting)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ES160 and is the answer not in the manual?

Questions and answers

Summary of Contents for EVERSPRING ES160

  • Page 1 ES160 detector module The ES160 is a PIR module to retrofit onto existing outdoor floodlight. It features a PIR detector to detect motion through movement of heat sources and a lux sensor plus for determining brightness of its surroundings. It is equipped with Z-wave wireless communication capability to upgrade the ordinary outdoor floodlight into a smart home device.
  • Page 2 3. Disconnect the mains wire from the floodlight by untwisting the wire nuts. 4. When done, place the floodlight on a table to prepare for wiring the ES160. 10. Route the power leads Hot and Neutral through the rubber gasket to get ready for wall mount.
  • Page 3: Operation

    Walk Test the process until the floodlight turns on. At this position the light will operate at The user can perform a walk test to ensure the PIR detector’s range falls within approximately the same level of darkness each evening. the desired area of coverage.
  • Page 4 Refer to Programming section for details of these notifications. Manufacturer Sensor Event Floodlight Manufacturer ID Product Type Product ID Z-wave commands/notification Remark behavior 0x0060 (Everspring) 0x0010 0x0001 sensor sensor When Trigger: AGI (Association Group Information) Table - Notification, PIR Trigger ON : Z-wave Group 1 command is Command Class &...
  • Page 5: Troubleshooting

    Troubleshooting Parameter Size Range Default Table below lists typical problems encountered: When PIR triggers: 30~200 : Lux level to turn on floodlight Symptom Possible Cause Recommendation 0 : Floodlight always off Floodlight does Power is not connected Check if wall switch is on. 255: Floodlight always on not turn on for 5 properly.
  • Page 6: Specifications