Advertisement

UniCAN 3
Version 01.00
Installation Manual
Innovative Measurement and Data Technology

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UniCAN 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for CSM UniCAN 3

  • Page 1 UniCAN 3 Version 01.00 Installation Manual Innovative Measurement and Data Technology...
  • Page 2 Copyright All concepts and procedures described in this document are intellectual property of CSM GmbH. Copying or use by third parties without the written permission of CSM GmbH is strictly prohibited. This document is subject to change without notice. Trademarks All trademarks mentioned in this document are the property of their respective owners.
  • Page 3: Table Of Contents

    UniCAN 3 – UniCAN 3 – Contents Contents 1 General information 1.1 Liability disclaimer 1.2 Warranty and exclusion of warranty 1.3 Electromagnetic compatibility (EMC) . 2 Safety instructions 2.1 General safety instructions 2.2 Obligations of the operator 3 Installing the device 3.1 General information .
  • Page 4: General Information

    CSM GmbH is not liable for technical or editorial errors or missing information. CSM GmbH assumes no liability for damage resulting from improper use of the product and/or non-observance of the product documentation, in particular the safety instructions.
  • Page 5: Safety Instructions

    UniCAN 3 – Safety instructions Safety instructions This chapter contains important safety information. Please read the following sections carefully. General safety instructions All relevant safety standards were taken into account during development and manufacturing of the device. The product is produced in accordance with the requirements of an ISO 9001 Quality Management System.
  • Page 6: Installing The Device

    Installing the device General information UniCAN 3 data loggers are used to record measurement data available over a CAN bus. They can be used for diagnostic purposes and for the long-term monitoring of systems and vehicles. UniCAN 3 data loggers are available in different versions. Each of these versions is also offered with isolated CAN interfaces.
  • Page 7: Led And Status Indicators

    Error state or firmware update in progress Tab. 3-3: Color codes for measurement (status LED) ① There is also a 2-digit, 7-segment display on the front of the UniCAN 3 ( ). This display supplements ⑤ the two LEDs and is used for visualization of device status and error codes. The location of a dot ( determines which display is currently active.
  • Page 8 UniCAN 3 – Installing the device Status values of the network LED Status indications for upload task Waiting for available resources Establishing network connection Writing SOM file Searching for updates (immediate) Uploading data Completing updates Searching for updates (delayed) Terminating network connection...
  • Page 9 ( ), i.e. the data logger attempts to establish a network connection (see Tab. 3-4). ⑤ ⑥ ① ② ③ ④ Fig. 3-3: UniCAN 3: example showing LED and status indicators on front Installation Manual Version 01.00 // 2018...
  • Page 10: Installation

    Information on the current status of device and associated software can be found in the “readme.txt” file of the CSMuniconf software installation package. The most current version of CSMuniconf can be found in the download area of the CSM website. See: https://s.csm.de/en-uc →...
  • Page 11: Putting Device Into Operation

    Fig. 3-6: Inserting SIM card with card holder NOTE! When inserting the SIM card into a UniCAN 3, make sure that the card holder is inserted into the slot with the SIM card facing upward. If the card holder is inserted with the SIM card facing downward, the card can fall out of the holder and damage the device.
  • Page 12: Connectors

    UniCAN 3 – Installing the device Connectors 3 6 1 Power supply and Ethernet UniCAN 3 data loggers are designed for an operating voltage of 8 V DC (–10 %) to 32 V DC (+10 %). The connection to power supply and Ethernet is made using a 7-pole LEMO 0B socket on the back of the ⑦...
  • Page 13: Can Interface

    3 6 2 CAN interface D-SUB-HD sockets, 15-pole (device) Depending on the version, the UniCAN 3 features up to three 15-pole D-SUB-HD sockets (see Fig. 3-1, ⑩  “CAN interfaces”, from left to right: CAN 1–4, CAN 5–8, CAN 9–12). The pin assignment of the first...
  • Page 14: Digital Inputs And Outputs

    UniCAN 3 – Installing the device 3 6 3 Digital inputs and outputs The connection to the digital inputs and outputs is made using a 7-pole LEMO 0B socket on the back ⑨ of the housing (see Fig. 3-1, “Digital I/O”).
  • Page 15: Antenna Connectors

    ) For compliance with FCC regulations, the antenna gain may not exceed 2 dB. UniCAN 3 data loggers are available in different versions. Not all device versions include a mobile communications modem (LTE / UMTS / EDGE / GPRS). Activation of the WLAN module and the GNSS module (GPS / GLONASS / BeiDou / Galileo) is always available as an option.
  • Page 16 All trademarks mentioned are property of their respective owners. Specifi cations are subject to change without notice. CANopen® and CiA® are registered community trade marks of CAN in Automation e.V. EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

Table of Contents