UNCTIONALITY PER USER INTERFACE 3.2 LCD SCREEN 3.2.1 S CHEDULE OPERATION SCREEN 3.2.2 C ONVENTION 3.2.3 S TATUS ANALYZER 3.3 O HART PERATION VIA 3.4 USB- PORT 3.4.1 S OFTWARE UPDATE 3.4.2 R SA 9D) HOSONICS SERVICE APPLICATION HOSONICS 4. CONFIGURATION www.rhosonics.com...
Page 3
ET CLOCK AND 7.1.4 L & OGGING AND ETTINGS FOR DIAGNOSTICS EVALUATION 7.1.5 C OLLECT LOG DATA USING 7.1.6 E RASE 8. DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) 8.1 USB- PORT ONLY ISTRIBUTORS AND ACTORY TRIMMING 8.3 T EMPERATURE 8.4 SG...
Page 4
10.1 L IST OF SPARE PARTS 10.2 O PTIONS 10.3 A A: S 100 °C PPENDIX OUND SPEED OF WATER AT 10.4 A B: D 100 °C PPENDIX ENSITY OF WATER AT 10.5 A C: F DD (HART) PPENDIX www.rhosonics.com...
Text represented as [Bold] indicates the button below the screen display to be pressed Text in ITALIC refers to text displayed on the screen display Pages on the screen display are represented as figures. The picture shown in the manual might differ from the picture shown on the display. www.rhosonics.com...
This chapter is valid for all sensor adapter types. In chapter 2.3 to chapter 2.5 the different SDM adapters mounting instructions are described. In “Provided by Rhosonics” a description of the different types of SDM adapters. In chapter 2.6 the SDM mounting instructions are described.
Page 7
In chapter 2.7 the electrical mounting instructions of the SDM are described. Must be provided on site: Mounting hardware e.g. bolts, nuts, washers, gasket sealing Power 24 VDC Power cable for 24 VDC HART/4-20mA cable Combined cable for Power 24 VDC and HART www.rhosonics.com...
Page 8
Standard: M16x1.5 SDM, split version (e.g. 52 mm tip) Process entry hardware for SDM This adapter exist in five different types: o SDM-1: Spool for 16 mm sensor tip, see chapter 2.3 SDM-1 Spool 16 mm tip www.rhosonics.com...
Avoid installation in a pipe section where the SDM tip may wear fast Avoid installation near dosing valves. Vertical pipe installation is preferred when the flow goes in upstream direction, see chapter 2.2.1. Horizontal pipe installation: Sensor must be installed sidewise, see chapter 2.2.2. www.rhosonics.com...
Some considerations need to be taken into account in case of installation in a horizontal pipe. The preferred installation in a horizontal pipe is shown below. The SDM must be installed either on the left or the right hand side of the pipe. 90° Horizontal pipe mounting (i.e. wafer) www.rhosonics.com...
CAUTION: Please make sure you will be very careful with rotating the housing. If not handled properly you can damage the SDM beyond repair, especially the spring loaded contacts in the sensor part. See also chapter Different housing positions www.rhosonics.com...
For gasket materials, please consult the responsible perosn for the original design of the piping system. 2.3.3 Bolting pattern and torque --------------------------------------------------------------------------------------------------------------------------- CAUTION: UNNECESSARY OVER TORQUING WILL DAMAGE THE SPOOL. Threads should be clean and well lubricated. Actual field conditions may require variations in these recommendations. --------------------------------------------------------------------------------------------------------------------------- www.rhosonics.com...
One final time after 24 hours - clockwise or counter clockwise sequentially around the flange. In below table, torque values are given for Rhosonics metal spools (SDM-1) and metal wafers (SDM-4 or SDM-5). These values assume the flanged joint connects the spool to a CLASS 150 flange. These values are for Spiral Wound Gaskets, ASME B16.5.
INSTALLATION IMPORTANT: Rhosonics does not take responsibility for any of these torque values, they're theoretical values. These bolt torque values are intended for use as guidelines only and are based on ideal conditions, perfect flanges, flange alignment & new well lubricated bolts/nuts. Torque values are based on using weld-neck flanges and lubricated stud bolts with a 0.16 friction factor.
This is the reason that the UHMWPE wafer is mentioned separately. The torque of the metal wafers (SDM-4 or SDM-5) is the same as the torque for spool piece (SDM-1). See concerning chapter 2.3 spool installation for torques of metal wafers. Vertical mounting (i.e. wafer) www.rhosonics.com...
Gasket material maybe either foamed PTFE, like Gylon, or an elastomer. For rubber lined pipes, additional gaskets are not recommended. Bolting pattern and torque --------------------------------------------------------------------------------------------------------------------------- CAUTION: UNNECESSARY OVER TORQUING WILL DAMAGE THE WAFER. Threads should be clean and well lubricated. Actual field conditions may require variations in these recommendations. --------------------------------------------------------------------------------------------------------------------------- www.rhosonics.com...
Page 17
Care must be taken to avoid “bending” the flange when joining a UWC wafer to a “raised face” flange. In below table, torque values are given for Rhosonics wafers. These values assume the flanged joint connects the wafer to a CLASS 150 flange, material UHMWPE.
Page 18
These estimated values are based on non-plated bolts and studs, using a K=0.16 for lightly greased bolts and nuts. Bolting must be done according to a crisscross pattern. Reseating is necessary after 24 hours. Reference: Bolt Torque For Polyethylene Flanged Joints TN-38/July 2011, www.plasticpipe.org www.rhosonics.com...
The main electrical parts, which are used in all models are called the 9D-series. Specific electrical parts for a specific model are 3A (SDM) parts. Power supply Input voltage 18 - 30 V DC Maximum Input Power Admissible ripple voltage USS < 1V [<100Hz] USS < 10mV [100Hz . . 10kHz] www.rhosonics.com...
Page 20
Size = 0.64 mm (22AWG), OD = 7.8 mm, Cap = 30 pF/m, Loop_DCR = 115 Ω/km Belden: 3079E DataBus ISA/SP-50 Size = 0.64 mm (22AWG), OD = 8.0 mm, Cap = 28 pF/m, Loop_DCR = 106 Ω/km www.rhosonics.com...
SDM housing through (a) cable gland(s). Inside the housing the cable(s) are connected to a screw connector. Below picture shows how to connect the power and HART. NOTE: Fuse specification Blow Characteristic: Fast Acting Fuse Current: 630mA Fuse Size: 5mm x 20mm Voltage Rating VAC: 250V www.rhosonics.com...
Page 22
SDM – Slurry Density Meter INSTALLATION Rear view SDM (back lit removed), including cable gland entries Connection 24 VDC and HART on rear side SDM (detail) www.rhosonics.com...
No more than 5 devices can be connected in multidrop-mode to the DCS to keep the current in the loop below 20mA. The loop current mode of the 9D-series analyzer has to be set to disabled and each device must have a unique polling address. www.rhosonics.com...
The secondary master can be a HART communicator or a HART modem connected to a computer. Procedure for point to point mode: Make sure the correct DD is in the database of the secondary master \YOUR_PATH\Library\0060C2\E35D Manufacturer ID Rhosonics: 0x60C2 Device Type: 0xE35D Device Type Name: 9D-series Analyzer Polling address: ...
Page 25
For multidrop mode it is necessary to disable the current output: Device setup->Detailed setup->Output condition->Analog output->Loop current mode. The analyzer can now be installed according the multi-drop mode configuration. When reconnecting the secondary master make sure the correct polling address is checked. www.rhosonics.com...
Set Check Function to On, screen becomes orange Result of Check Function set to On Go to the Device Manager on the PC. AT91 is now present at COM-port (PC) Device manager (Dutch version Windows: Apparaatbeheer), AT91 USB on COM-port number 9 (COM9) www.rhosonics.com...
Page 27
SDM – Slurry Density Meter INSTALLATION Start-up Rhosonics_SA _9D_##_##.exe COM9 selected Connection is made between sensor and service program. Whenever the green light is on and the echo is visible. www.rhosonics.com...
Operations via HART, see chapter 3.3 Operations through the USB-port, see chapter 3.4 The choice for each user interface is dependent on the type of user. Setup is as follows: Operating overview with:type of user interface, type of user and access level www.rhosonics.com...
Real time echo monitoring Saving log data Loading liquids Loading firmware Save settings Error log Reading writing device location Reading version information Reading model type * Only for Distributors www.rhosonics.com...
A minor system status displays the most relevant error in case of measurement problems.To assure settings can only be changed by authorized personal most menu’s are hidden behind an access level. www.rhosonics.com...
Second button: Go down Third button: Accept or Main menu Fourth button: Back / Page level higher (see schedule 3.2.1) If the button colors are reversed (only first and second button) means that this button is used last. www.rhosonics.com...
Output is valid Output is valid The backlight color is green. The backlight color is green. Locked (Remote access) Locked (Remote access) Access level 2 In time Out Access level will be reset to level 1. www.rhosonics.com...
Page 33
Icon in upper right corner and backlight change Backlight in orange. Icon and measurement into orange. values are alternating. Failure Failure Replace device Replace device Backlight in red. Icon and measurement values Icon in upper right corner and backlight change into red. are alternating. www.rhosonics.com...
The procedure for software update: Power off the analyzer Insert an USB-stick with the latest software and the file bootscript.img Power on the analyzer Wait a few seconds Disconnect the USB-stick The analyzer is updated. www.rhosonics.com...
SDM – Slurry Density Meter OPERATION 3.4.2 Rhosonics service application (Rhosonics SA 9D) The Rhosonics service application has 4 tabs Main, Configuration, Calibration, and diagnostics. The structure of the application is the following: www.rhosonics.com...
If you want to view all values, go to the Measured Values pages. First to the Main Menu then to the Measured Values page. Press to go tot he Main Menu. IMPORTANT: If you are in Time Out mode press any key first to go to the Start Page. www.rhosonics.com...
Back light changes with the status of the analyzer. Certain statuses can cause the back light color to be too weak. It is possible to set the back-light into black and white mode to make sure that independent of the status the screen is visual. www.rhosonics.com...
On the Liquid Select page you can choose 2 options: Water measurement: only water can be measured, polynomials for water are standardly stored in the analyzer. Normal operation: a set of polynomials is loaded into the analyzer. This setting is specifically for its application. www.rhosonics.com...
As a consequence the analyzer (and mA out) will go into the out of specification status, when the measured value will go out of these range. Screens below shows the menu and the pages where the upper and lower range value can be set. www.rhosonics.com...
Make sure the correct DD is in the database: \YOUR_PATH\Library\0060C2\E35D o (Manufacturer ID = 0x60C2) o (Device ID = 0xE35D) Open Analyzer.ddl Build DD [Ctrl + M] Execute [Ctrl + F5] SDC625 is opened www.rhosonics.com...
The PV Alrm typ (Primary Variable Alarm Type) is the Error reaction mode The Loop current mode has to be Enabled (Disabled is Multidrop-mode) The Loop test sets the output to a set value The D/A trim trims the low and high value on digital level www.rhosonics.com...
Page 42
Set mode for PV Alrm typ (choose from Hi, Lo, Hold last value or None) Set Loop current mode to Enabled Use D/A trim to fine-tune the 4 mA and 20 mA value digitally. After this trim a power down and power up must be done. Analog output condition www.rhosonics.com...
In this case the files are necessary to get the description for the settings. When this location doesn’t exist please create this location. Press Read settings When the descriptions and values in analyzer are visible and the file column is greyed out the settings are read from the analyzer www.rhosonics.com...
Page 44
Save the file (keep .csv extension) Press Load settings When Lamp Settings loaded is green the settings are loaded The Primary, Secondary, Ternary and Quaternary values for HART output are now set. www.rhosonics.com...
The temperature must be ± 5 °C the real process temperature. Enter temperature Offset using buttons. After entering the Offset press the button. 5.1.2 S.G. x 1000 calibration On the S.G. x 1000 page you can calibrate the Offset and Span. www.rhosonics.com...
Page 46
Simply change the shown value until it reaches the reference value. Correct density values Since Rhosonics uses the acoustic impedance to measure the density, which is a linear function, the density meter will now read the correct density value in between this range (1000 –...
By changing the span you get the expected result of the calibration Enter S.G. x 1000 Span using buttons. After entering the Span press the button. 5.1.3 Field calibration Field calibration has no effect for the SDM. www.rhosonics.com...
Please make sure you follow this procedure. Deviating (dis)mounting procedure can damage the SDM beyond repair, especially the spring loaded contacts in the sensor part. Sensor mounted in wafer/spool/weldolet Dismounting: Untighten 8 M5x16 bolts / Mounting: tighten bolts with 4.2 Nm www.rhosonics.com...
Page 49
SDM – Slurry Density Meter MAINTENANCE Dismounting: Remove sensor from pipe(adapter) / Mounting: place sensor into pipe(adapter) Dismounting: Remove nuts from Tri-clamp / Mounting: Tighten nuts to Tri-clamp with 25 Nm Dismounting: Remove Tri-clamp / Mounting: Place Tri-clamp www.rhosonics.com...
Page 50
Dismounting: Separate sensor and housing, NOTE take care of the tiny spring loaded contacts in the sensor part / Mounting: Connect sensor and housing, NOTE take care of the tiny spring loaded contacts in the sensor part Dismounting: Remove the M5x16 bolts and M5 washers / Mounting: Place the M5x16 bolts and M5 washers www.rhosonics.com...
When the analyzer is not running OK anymore, it shows the error and information about that error. 7.1.2 Restore calibrations Preparations Please read this section carefully before starting! On this page you can restore all calibrations to the factory calibrations. www.rhosonics.com...
For trouble shooting this is the proper way to solve the problem: 1. Check System Status and inform Rhosonics / the Distributor 2. Save a log-file and analyzer settings and send them to Rhosonics / the Distributor 3. Restore factory settings, only when Rhosonics tells you to do so.
The flashing of loading data as well as the updating of the progress bar indicates that saving the data is in progress. When saving data is finished the message loading complete appears. It is now possible to leave this page and remove the USB-stick. www.rhosonics.com...
The device is permanently logging. This has the advantage that after an incidental measurement error the log can be retrieved. When a test is started there can be a desire to clear the data already present in the analyzer. Pressing to erase the log. www.rhosonics.com...
SDM – Slurry Density Meter DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) Distributors calibration (for Rhosonics and distributors only) USB-port (only Distributors and Factory) The USB-port is used for: Distributor calibrations using a PC via the service application. ...
DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) mA trimming For mA trimming a calibrated mA meter is necessary. The SDM is calibrated at Rhosonics. A step by step instruction is given on the service application via several pop ups. Temperature Check the temperature reading regularly, and perform a calibration when the reading error exceeds 5 ºC.
Page 57
SDM – Slurry Density Meter DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) Enter the certified temperature followed by pressing OK OK stores the result www.rhosonics.com...
SDM – Slurry Density Meter DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) SGx1000 calibration 8.4.1 SGx1000 offset calibration Press SG offset calibration Enter a certified SGx1000 Enter Certified SGx1000 A button Calibrate will appear on the screen Calibrate button ...
SDM – Slurry Density Meter DISTRIBUTORS CALIBRATION (FOR RHOSONICS AND DISTRIBUTORS ONLY) When the timer Wait(s) is 0 seconds the calibration is done, the Measured SGx1000 should be near the Certified SGx1000 8.4.2 SGx1000 span calibration The SGx1000 span calibration can be performed by 2 methods.
Pillow embossed metal dome, 4 pieces Weight 6.4-6.8 kg Power consumption maximum 8 W Fuse (24 VDC) 5x20 mm, 630 mA (T) Storage conditions -40°C to +75°C --------------------------------------------------------------------------------------------------------------------------- WARNING: Do not open the covers when circuits are alive in hazardous areas. --------------------------------------------------------------------------------------------------------------------------- www.rhosonics.com...
Weldolet: o SDM-2 up to wall thickness 17 mm o SDM-3 wall thickness 17-39 mm Wafer: Diameters up-to 60” (NW 1500 mm) Please contact Rhosonics for exact dimensions. All is depending on the pipe schedule and flange specifications. www.rhosonics.com...
HART to Modbus RTU converter, Art#: 9999-GATEWAY-GW-800-B Service kit, Art#: 9D-SERVICE-KIT (contains USB-A male to USB-A male cable, 2 meter and Rhosonics software for service), Distributors only 10.3 Appendix A: Sound speed of water at 0 to 100 °C T [°C]...
SDM – Slurry Density Meter APPENDICES 10.5 Appendix C: Flow DD (HART) www.rhosonics.com...
Page 65
SDM – Slurry Density Meter ABOUT US MEASURING BEYOND LIMITS CONTACT US Rhosonics Analytical B.V. At Rhosonics, we continuously work on Hoge Eng West 30 improving our analysers and sensors. We 3882 TR Putten, The Netherlands believe that we can offer solutions for almost any application.
Need help?
Do you have a question about the SDM Series and is the answer not in the manual?
Questions and answers