Default
Item
setting
This mode can change the threshold value depending
Setting of
threshold value
tions of the incident light intensity. The tracking shift
tracking
amount is the one which is set at the shift setting.
Sensing
Selects whether tracking threshold when the output is
output setting
OFF or when the output is ON.
Storage cycle
setting
to 250 times.
When setting to limit teaching, threshold value is fol-
Algorithm
lowed up on the bases of shift amount. Furthermore,
setting
when setting to auto teaching, threshold value be fol-
lowed up on the bases of each cycle
Shift direction of the threshold differs depending on the combination of the sensing
output status and the sensing output operation.
Sensing output status
Sensing output operation
Sensing output ON
Light-ON
Sensing output ON
Dark-ON
Sensing output OFF
Light-ON
Sensing output OFF
Dark-ON
Forth digit
Sensing output opera-
Timer operation
tion mode
Sensing
Sensing
Sensing
output 1
output 2
output 1
Light-ON
Light-ON
No timer
Light-ON
Dark-ON
OFD
Dark-ON
Light-ON
OND
Dark-ON
Dark-ON
ONOF
OSD
ONOS
No timer
No timer
No timer
OFD: OFF-delay timer, OND: ON-delay timer
ONOF: ON / OFF-delay timer, OSD: One-shot timer,
ONOS: ON-delay / One-shot timer
Forth digit
Setting items
Copy lock
Hysteresis
in digital dis-
setting
setting
play setting
Copy lock
Incident light
H-02
OFF
intensity
Copy lock
Incident light
H-02
ON
intensity
Copy lock
Displayed in
OFF
percentage
Copy lock
Displayed in
ON
percentage
Copy lock
Peak / bot-
H-01
OFF
tom value
Copy lock
Peak / bot-
H-01
ON
tom value
(WC mode: Window comparator mode, HYS mode: Hysteresis mode)
Note: It is a setting only for sensing output 1. Sensing output 2 is not set.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
Shift direction
-
+
+
-
Second
Third digit
digit
Timer
Sensing
period
output 2
No timer
0.5ms
No timer
1ms
No timer
No timer
5ms
No timer
10ms
No timer
OFD
50ms
OND
100ms
OSD
500ms
1 sec.
2 sec.
4 sec.
5 sec.
Second
Third digit
digit
Back up
setting
time setting
Back up ON
H-SP
Back up OFF
FAST
Back up ON
STD
Back up OFF
LONG
Back up ON
U-LG
Back up OFF
13

ERROR INDICATION

In case of errors, attempt the following measures.
Error in-
-
dication
the end of its working life.
Load of the sensing output 1 is short-
Load of the sensing output 2 is short-
Communication error when the Verify that there is no loose or clear-
Communication error between the
upper communication unit and
14

OPTICAL COMMUNICATION

When the setting of data bank loading / saving, copy setting, or copy ac-
tion setting is conducted via optical communications, cascade the sub
bank loading / saving, or copy setting cannot be carried out .
First digit
Digital display is blinking
When communication protocol of a sub amplifier is set to communication
CUSTOM
setting
Make sure to mount closely like follows since interference prevention
time setting
function is conducted by optical communication.
Emission
power setting
Hysteresis
setting
sure sensor controllers, etc.) are connected together in cascade, install
those products so that they are in order of Group A, B, C, and D as
Communication direction
Group
Group
A
B
dow of each corresponding product.
First digit
Within each group, identical models should be connected in a lump.
Sensing
output
sensor controllers, etc.) are connected together in cascade, items that
mode
can be copied at Copy setting are limited.
(Note)
Normal
time period hold setting and CUSTOM setting.
mode
In case conducting copy setting of this device and other FX-500 series
together, functions which are incorporated in this device will be copied
WC mode
but functions which are not incorporated in this device will not be copied.
-
This device can not copy the threshold value.
ential mode
Trailing differ-
ential mode
HYS mode
Description
Turn OFF the power and check the
load.
Verify that there is no loose or clear-