Operating manual industrial motors
BAIndustrie_UK | Version 1.0 | 2016.04.12
ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nova 15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Plettenberg Nova 15

  • Page 1 Operating manual industrial motors BAIndustrie_UK | Version 1.0 | 2016.04.12 ENGLISH...
  • Page 2: Table Of Contents

    Environmental and climatic conditions ........8 Structure of internal rotor ............9 Commissioning ..............10 Safety during commissioning ..........10 Assembly ................10 Nova 15 ................11 Nova 30 ................12 HP 370 ................14 HP 505 ................17 HP 600 / HP 620..............19 Cable connections ...............
  • Page 3: Notes Regarding This Document

    The information contained in this document is the sole property of Plettenberg Elektromotoren GmbH & Co. KG. Publication, in whole or in part, requires the express written consent of Plettenberg Elektromotoren GmbH & Co. KG. An internal company duplication, which is intended for the evaluation of the product or for the appropriate assignment, is permitted and not subject to approval Plettenberg Elektromotoren GmbH &...
  • Page 4: Scope Of Valitidy

    Scope of valitidy This document applies for the following device types: Motor type Nova 15 Nova 30 HP 370 HP 505 HP 600 HP 620 Target group The activities described in this document may only be executed by qualified, skilled workers. The qualified, skilled workers must...
  • Page 5: Savety

    2. Savety Intended use The motor series of the validity range are intended for this purpose: As drive unit  Unapproved use in the sense of a foreseeable misuse shall be deemed to be improper use: the drive unit in man-bearing devices ...
  • Page 6 The maximum bending radius of the connecting cables must  not be undershot. 6 x outer diameter. To prevent high-impedance connections, only gold contact  plugs from Multi-Contact, Plettenberg or Schnepp are permitted. Assembly and/or dismantling only when de-energised.  operating manual...
  • Page 7 Injuries due to crushing, being caught up Malfunction due to electromagnetic interference. The control and phase cables must not be extended. The  product must be inspected and the fastening must be controlled again before commissioning. Modifications to the product are not permitted. ...
  • Page 8: Product Overview

    [V] [kg] [1/min] [mm] Nova 15 (HV) 2,5 – 3,1 30 – 80 (120) 5000 Nova 15 „S“ (HV) 2,5 – 3,1 30 – 80 (120) 11000 Nova 30 5 – 6,5 30 - 140 5000 30 C=1:10 Nova 30 „S“...
  • Page 9: Structure Of Internal Rotor

    Structure of The windings are located in the motor housing. Permanent in-running motor magnets are attached to the axis and rotate in the magnetic field of the windings. Type: Nova 30 mit Wasserkühlung 1: motor phase 1 (red) 2: motor phase 2 (yellow) 3: motor phase 3 (blue) 4: sensor wire 5: shaft...
  • Page 10: Commissioning

    4. Commissioning Safety during commissioning Severe, moderate or minor injuries. Destruction or damage to the product. Safety instructions from Chapter 2 must be complied with! The motor phases must not be shortened without prior consultation. Crimping of connections may also not be executed without previous consultation.
  • Page 11: Nova 15

    The motor is fixed with 6 M5 bolts. Maximum screw-in depth: 9 mm Maximum tightening torque: 6 Nm Nova 15/xx WK (40 = 87mm; 50 = 97mm) The motor is fixed with 6 M5 bolts. Maximum screw-in depth: 9 mm...
  • Page 12: Nova 30

    Nova 30 Nova 30/50 The motor is fixed with 6 M6 bolts. Maximum screw-in depth: 10 mm Maximum tightening torque: 10 Nm operating manual BAIndustrie_UK...
  • Page 13 Nova 30/50 WK The motor is fixed with 6 M6 bolts. Maximum screw-in depth: 10 mm Maximum tightening torque: 10 Nm operating manual BAIndustrie_UK...
  • Page 14 HP 370 HP 370/xx (30 = 73 mm; 40 = 83 mm; 50 = 93 mm) The motor is fixed with 6 M4 bolts. Maximum screw-in depth: 8 mm Maximum tightening torque: 3 Nm operating manual BAIndustrie_UK...
  • Page 15 HP 370/XX MKR (30 = 73 mm; 40 = 83 mm; 50 = 93 mm) The motor is fixed with 6 M4 bolts. Maximum screw-in depth: 8 mm Maximum tightening torque: 3 Nm operating manual BAIndustrie_UK...
  • Page 16 HP 370/50 WK The motor is fixed with 6 M4 bolts. Maximum screw-in depth: 8 mm Maximum tightening torque: 3 Nm operating manual BAIndustrie_UK...
  • Page 17 HP 505 HP 505 The motor is fixed with 6 M4 bolts. Maximum screw-in depth: 8 mm Maximum tightening torque: 3 Nm operating manual BAIndustrie_UK...
  • Page 18 HP 505/50 WK The motor is fixed with 6 M4 bolts. Maximum screw-in depth: 8 mm Maximum tightening torque: 3 Nm operating manual BAIndustrie_UK...
  • Page 19 HP 600 / HP 620 HP 600/xx / HP 620/xx (30 = 100,5 mm; 37 = 110,5 mm; 40 = 110,5 mm; 50 = 118,5 mm) The motor is fixed with 4 M6 bolts. Maximum screw-in depth: 12 mm Maximum tightening torque: 10 Nm operating manual BAIndustrie_UK...
  • Page 20 HP 600/xx WK; HP 620/xx WK (40 = 108,5 mm; 50 = 118,5 mm) The motor is fixed with 4 M6 bolts. Maximum screw-in depth: 12 mm Maximum tightening torque: 10 Nm operating manual BAIndustrie_UK...
  • Page 21: Cable Connections

    The sensor cable must be connected to the controller in accordance with the regulator manufacturer's specifications. The brush-free Plettenberg motors with sensors are either equipped with 3 hall sensors or with 3 fork light barriers with 120° electrical angle. The sensors have open-collector outputs with pull-up resistors.
  • Page 22: Settings

    Commutation sequence backwards Step1 Step 2 Step 3 Step 4 Step 5 Step 6 Error1 Error2 Phase A(U) Phase B(V) Phase C(W) Sensor A Sensor B Sensor C Z: High impedance, +:Plus, -:Minus, 1:>3 V, 0:<2 V Settings The motor speed must be controlled with a revolution speed measuring device.
  • Page 23: Troubleshooting

    5. Troubleshooting It is absolutely necessary to install the receiver as far away as possible from the motor, regulator, controller and/or its current- carrying cables. The aerial must not be laid past the motor and its current-carrying cables. If this is not possible for structural reasons, then these elements must be shielded with sheet steel or foil.
  • Page 24: Service / Contact

    Should, despite proper handling and sufficient care, problems should still occur or the motor will be damaged, then please send the motor back to our address stating the problem, defect or damage. Plettenberg Elektromotoren GmbH & Co. KG Rostocker Straße 30 34225 Baunatal – Großenritte GERMANY...
  • Page 25: Eu-Declaration Of Conformity

     Low Voltage Directive 2014/35/EU Appendix IV  RoHS Directive 2011/65/EU Appendix I Plettenberg Elektromotoren GmbH & Co. KG Rostocker Straße 30 34225 Baunatal – Großenritte hereby declares, as the manufacturer, that the articles and objects described below comply with the provisions of the relevant community harmonisation legislation referred to above.
  • Page 26 Plettenberg Elektromotoren GmbH & Co. KG and when components, not belonging to Plettenberg Elektromotoren GmbH & Co. KG, or accessories are installed in the product as well as in the event of improper connection or improper use of the product.