VL260 CONTROL
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and
Fill the spa to its correct operating level. Be sure to open all valves and
jets in the plumbing system before lling to allow as much air as pos-
sible to escape from the plumbing and the control system during the
lling process. When your spa is rst actuated, it will go into Priming
mode, indicated by "
" The Priming mode will last for less than
PR
5 minutes (press „Cool" or „Warm" to skip Priming Mode) and then the
spa will begin to heat the spa and maintain the water temperature in
the Standard mode.
Buttons
JETS
Press the "Jets"
button once to turn pump on or o , and to shift
between low and high speeds if equipped. If left running, the pump
will turn o after a timeout period. The pump low speed timeout on
some systems may be as long as 4 hours. On non-circ systems, the low
speed of pump 1 runs when the blower or any other pump is on. It
may also activate for at least 1 minute every 30 minutes to detect the
spa temperature (polling) and then to heat to the set temperature if
needed, depending upon mode. When the low speed turns on auto-
matically, it cannot be deactivated from the panel; however, the high
speed may be started.
COOL
WARM – SET TEMPERATURE
The last measured temperature is constantly displayed on the LCD
screen.
Please note that the last measured water temperature only ap-
pears exactly when the pump has run at least for 1 minute.
To display the set temperature, press the Cool
button once. To change the set temperature, press the button a
second time before the LCD stops ashing. Each press of the "Cool" or
"Warm" button will continue to either lower or raise the set tempera-
ture. After three seconds, the LCD will stop ashing and display the
current spa temperature.
LIGHT
Press the "Light"
button to turn the light on and o . If left on,
the light automatically turns o after 4 hours.
MODE
Mode is changed by pressing the "Cool"
button, then pressing the "Light"
Standard Mode is programmed to maintain the desired tempe-
rature. Note that the last measured spa temperature displayed
is current only when the pump has been running for at least 2
minutes. "
Standard Mode.
Economy Mode heats the spa to the set temperature only during
lter cycles. "
and will alternate with temperature when temperature is current.
Sleep Mode heats the spa to within 20°F/10°C of the set tempera-
ture only during lter cycles. "
rature is not current, and will alternate with temperature when
temperature is current.
Preset Filter Cycles
The rst lter cycle begins 6 minutes after the spa is energized.
The second lter cycle begins 12 hours later. Filter duration is
or Warm
programmable for 2, 4, 6, 8 hours or for continuous ltration
(indicated by "
To program, press "Cool"
Press "Cool" or "Warm" to adjust. Press "Jets" to exit programming.
For more information, please, check the User Manual.
button.
" will be displayed momentarily when you switch into
St
" will display solid when temperature is not current,
Ec
" will display solid when tempe-
Sl
"). The default lter time is 2 hours.
FC