Download Print this page
Sloan Optima Plus EBV-500-A Installation Instructions

Sloan Optima Plus EBV-500-A Installation Instructions

Dual-flush and single-flush side mount unit

Advertisement

Quick Links

Optima Plus
Side Mount Unit Installation Instructions
EBV-500-A
Single-Flush Side Mount
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material
and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first
purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this
warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at
customer's cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve
Company's products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF
ANY MEASURE WHATSOEVER.
1 - INSTALLATION (FOR EITHER LEFT- OR RIGHT-HAND)
DO NOT REMOVE STICKER FROM SENSOR
WINDOW UNTIL STEP 2.
Close the control stop.
Using the supplied collar wrench, remove handle
from flushometer, if applicable.
On some flushometers with
NOTE:
a faulty air vent, or recently flushed valve, be
prepared to collect a small amount of water with a
rag or sponge placed under the handle.
Place sleeve assembly with flat notch facing
upwards into collar nut and attach the Side Mount
unit where the handle was removed.
NOTE:
Failure to install flat notch correctly can
result in damage to the unit.
Tighten collar nut with supplied collar wrench.
Open the control stop.
Save the handle in the event you wish to
NOTE:
return to manual flushometer.
Dual-Flush and Single-Flush
®
LIMITED WARRANTY
FLAT NOTCH
GASKET
EBV-550-A
Dual-Flush Side Mount
COLLAR NUT
SLEEVE ASSEMBLY
Code No. 9108310
Rev. 6 (08/13)

Advertisement

loading
Need help?

Need help?

Do you have a question about the Optima Plus EBV-500-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Sloan Optima Plus EBV-500-A

  • Page 1 (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service.
  • Page 2 For retrofit installation to Zurn flushometer make sure to NOTE: re-use the Zurn gasket and place on top of sleeve assembly before mounting to valve. Contact Sloan Technical Support if the Zurn gasket is not present or if another is required. EBV-576...
  • Page 3 The unit has failed to calibrate. The optics window is obscured. Remove power, clean window and remove any objects (barrels, toolboxes, etc.) within close proximity of unit. Repeat power-up sequence. If unit fails, consult Sloan Technical Support. When assistance is required, please contact Sloan Technical Support at:...
  • Page 4 EBV-157 ADAPTER EBV-576 GASKET (FOR -G VARIATION ONLY) (FOR -G VARIATION ONLY) Manufactured in China by Sloan Valve Company. US Patents Patent Pending. OPTIMA PLUS ® The information contained in this document is subject to change without notice. AIR DELIGHTS, INC. • 11170 SW 5TH ST. #100 • BEAVERTON, OR 97005 Phone: 1-800-440-5556 or 503-352-1201 •...

This manual is also suitable for:

Optima plus ebv-550-a