Nidec E300 Series Installation And System Design Manual page 22

Elevator drive. model sizes 3 to 11. dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Table 2-7 Option module identification
Option
Type
module
Feedback
Automation
(I/O
expansion)
Automation
(Applications)
Table 2-8 Keypad identification
Type
Keypad
Remote-Keypad
Keypad
RTC
22
Electrical
Getting
User Menu A Commissioning
installation
started
Color
Name
15-way D-type
N/A
converter
Single ended
N/A
encoder interface
(15 V or 24 V)
Light Brown
SI-Encoder
SI-Universal
Dark Brown
Encoder
Orange
SI-I/O
Moss Green
MCi200
Moss Green
MCi210
SI-Applications
Black
Plus
Black
SI-DCP
Name
Part number
82400000019600
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Part number
Drive encoder input converter
Provides screw terminal interface for encoder wiring and
82000000012200
spade
terminal for shield
Single ended encoder interface
15 V=
Provides an interface for single ended ABZ encoder
82000000013600
signals,
24 V =
such as those from hall effect sensors. 15 V and 24 V
82000000014800
versions are available
82400000018100 Incremental encoder input interface module.
Additional combined encoder input and output interface
82400000018300
supporting Incremental, SinCos, HIPERFACE, EnDAT
and SSI encoders.
Extended I/O
Increases the I/O capability by adding the following
combinations:
Digital I/O
82400000017800
Digital Inputs
Analog Inputs (differential or single ended)
Analog Output
Relays
Machine Control Studio Compatible Applications
Processor
82400000017000
2nd processor for running pre-defined and/or customer
created application software.
Machine Control Studio Compatible Applications
Processor (with Ethernet communications)
82400000016700
2nd processor for running pre-defined and/or customer
created application software with Ethernet
communications.
SyPTPro Compatible Applications Processor
(with CTNet)
82400000016500
2nd processor for running pre-defined and/or customer
created application software with CTNet support
(can only be used on Slot 3).
82400000019900 DCP3 and DCP4 Interface module
Remote LCD keypad option
Remote Keypad with a LCD display and real time clock
Further Details
Further Details
Installation and System Design Guide
Issue Number: 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents