SUPPLY:
12VDC @ 100mA for
INDICATION:
AUDIBLE:
CONTROL:
OPTIONS:
DIMENSIONS:
MOUNTING:
TEMPERATURE:
2
3
4
GJD SAPPHIRE MK3
1500
230Vac 50Hz via ELCB/MCB. - unit fused at 10A
GJD Opal XL (6mA) or Elite Detectors (10mA)
Optional external 12VDC piezo sounder upto 50mA
Four 24 hour detector indicators which pulse during detection and
are steady after detection for the duration of the light on timer setting.
Internal warning tone which sounds on detection day and night,
and is button selectable.
Controls upto 8 x GJD detectors. Switches one area of lighting
with manual override when required.
Ability to activate lighting with remote push button.
Ability to have an auxiliary output.
Ability to activate lighting when linked to an intruder alarm panel.
146(W) x 86(H) x 56(D) mm Weight 495gm
Indoor use only.
Mount in a clean dry location on a secure flat surface
-10 TO + 55 Centigrade
Self contained - Class 2 independently mounted control.
GJD S
APPHIRE
T
HE
SECURITY LIGHTING CONTROLLER WHICH
ENABLES EXTERNAL AREAS TO BE
ACCURATELY MONITORED
WATTS OF LIGHTING AT NIGHT FOR A PRE
. T
HE CONTROLLER INCORPORATES AN
.
- 1 -
MK3 L
IGHTING
I
NSTALLATION
P
N
ART
UMBER
GJD S
APPHIRE IS A SINGLE AREA
C
ONTROLLER
M
ANUAL
GJD005
.
-
SET PERIOD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAPPHIRE MK3 and is the answer not in the manual?

Questions and answers

Summary of Contents for GJD SAPPHIRE MK3

  • Page 1 Internal warning tone which sounds on detection day and night, and is button selectable. CONTROL: Controls upto 8 x GJD detectors. Switches one area of lighting with manual override when required. OPTIONS: Ability to activate lighting with remote push button.
  • Page 2 PERATING NSTRUCTIONS When a detector is activated day or night the relevant detector indicator flickers and will remain on for the length of the timer setting. During darkness the lighting will be switched on automatically while the detector is receiving activation signals, and will automatically turn off after the preset timer period.
  • Page 3 DJUSTMENT TO FACTORY SETTINGS When connecting the unit to the electrical supply or when the supply is interrupted, the indicators will flash for one minute whilst the system settles. Pressing any button during this time will start normal operation. Internal adjustments panel The factory settings are shown.
  • Page 4 (2) Activate zone lighting for alarm period when linked to an intruder alarm panel. All diodes: IN4148, IN4002 etc Caution if this equipment is intended for applications not specified please contact GJD prior to installation. GJD Reserve the right to alter the specification without notice.

Table of Contents