Banner SC22-3 Instruction Manual page 66

Safety controller
Hide thumbs Also See for SC22-3:
Table of Contents

Advertisement

SC22-3/-3E Safety Controller Instruction Manual
1. Use the left/right arrows to select the character position.
2. Use the up/down arrows to select the character for each position (choices
A-Z, 0-9, -, +, or space).
3. When the screen (as shown below) shows the correct device name, press
OK.
Input Properties Menu—The Input Properties menu is used to:
Select the input device's circuit type
Edit the terminal assignments, if needed
Select the output(s) (or input), the input will control
Select between automatic and manual reset logic (depending on device)
Select the Circuit Type of the Input—Use the up/down arrows to select Select Circuit Type, and press OK.
See section
Input Device and Safety Category Reference
circuit integrity levels and the capabilities of each circuit type.
1. The Select Circuit Type menu appears.
2. Use the left/right arrows to select the desired circuit type (a dual-channel, 4-
terminal circuit type is shown below) for the input device and press OK.
3. After the circuit type is selected, the display returns to the Input Properties
menu.
Edit the Terminal Assignments—When the input circuit type is selected, the Safety Controller automatically assigns the
next available terminals for the input device. Only unassigned terminals can be assigned. (Exception: Terminals used for a
specific input device can be assigned twice during the edit process, if the same terminals will be used, in a different order,
for this specific device.) To view and change these terminal assignments, select Edit Terminals, and press OK.
1. Use the left/right arrow buttons to select the terminal assignment to be
changed.
2. Use the up/down arrows to change the terminal assignment.
3. When the terminal assignments are as desired, press OK.
4. After the terminal assignments are approved, the display returns to the Input
Properties menu.
Map Outputs—This option is used to select which of the Safety Output(s) the input controls. Any combination of 1, 2, or
all 3 outputs may be selected, but at least one must be selected. All safety devices, plus reset and ON/OFF non-safety
devices must be mapped to one or more Safety Outputs. Map mute enable devices, mute sensors, and bypass sensors to a
safety input device.
1. Select Map Outputs in the Input Properties menu, and press OK.
2. To map the input to an output, use the up/down arrows to select the
output, then press OK.
3. A filled-in circle on the display indicates the input is mapped to the
corresponding output; an empty circle indicates the input is not mapped to
that output.
4. To add or remove the input mapping, select the output and press OK. When
the input is mapped to the Safety Outputs as desired, select Save and press
OK.
5. After the input is mapped to the Safety Outputs, the display returns to the
Input Properties menu.
The screen shows device ES01 mapped to all three Safety Outputs.
Select Reset Logic—To select automatic or manual reset logic, select Reset Logic and press OK.
1. Use the left/right arrows to select the desired reset logic parameter and press OK.
2. The display returns to the Input Properties menu.
66
on page 86 for more information about safety
www.bannerengineering.com - Tel: 763.544.3164