Download Print this page
Argos FireStar ST Instruction Manual
Argos FireStar ST Instruction Manual

Argos FireStar ST Instruction Manual

Safety enhanced laboratory gas burner

Advertisement

Quick Links

EN
Instruction manual
Safety Enhanced
Laboratory Gas Burner
2006/95/EG
2004/108/EG
EN 61326, 61010
DIN 30665, part 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the FireStar ST and is the answer not in the manual?

Questions and answers

Summary of Contents for Argos FireStar ST

  • Page 1 Instruction manual Safety Enhanced Laboratory Gas Burner 2006/95/EG 2004/108/EG EN 61326, 61010 DIN 30665, part 1...
  • Page 2 1 - Function knob 2 - Dual knob: - Gas adjustment - Air adjustment 3 - LED Standard 4 - LED StartStop 5 - LED Button 6 - LED Burner head HOT / BHC 7 - Burner head 7a - Flame orifice 8 - Connector for foot pedal 9 - Power connector for 9 V DC 10 - Gas inlet R 1/4“...
  • Page 3 Read these instructions carefully to familiarize yourself with the product. Please retain these operating instruction for future reference. Safety laboratory gas burners for heating and flame sterilizing. Ideal for use in cleanroom workbenches and laboratory. All users who have been assigned to use this device must have read and understood these operating instructions or have been instructed by an expert user so that this device can be used safely without causing danger.
  • Page 4 Safety Precautions • On unpacking the unit, check for possible transportation damages. Do not operate the unit if damages are visible. • The device can be dangerous if operated or used in an incorrect manner by untrained staff. • An incorrect gas connection may create a hazard. Observe the installation instructions in the manual.
  • Page 5 • NEVER use a open flame to look for leaks. • Do not smoke if you are searching for leaks. • NEVER try to loosen or unfasten gas connections while the gas supply is turned on and the device is in operation. •...
  • Page 6 The range: FireStar ST Cat. No.: FST100 with foot pedal (26) 3 standard-programs for button (function knob) and foot pedal SCS (Safety Control System) BHC (Burner Head Control) Removable and decomposable burner head Tilt mechanism, right / left (23) Holding device for 3 inoculation loop holders (11)
  • Page 7: Electrical Connection

    1.2 Electrical connection: Plug the power cable into the socket (9) on the back of the unit or into the socket on the foot pedal. The mains power supply unit included is designed for a voltage from 100 - 240 V, 50/ 60 Hz.
  • Page 8 - BHC: If the burner head is clogged the amber LED “Burner head HOT / BHC“ will flash. Additionally, if “burner head HOT / BHC“ is flashing, the maximum burning time in the operating mode “Button“ and Pedal “StartStop“ is limited to 30 seconds (see paragraph 2.2). If burning times longer than 30 seconds are required in case of a clogged burner head, the operating mode “Standard“...
  • Page 9 All FireStar are covered under our two-year manufacturer warranty against any manufacture defects in material and workmanship. The Argos warranty guarantees all FireStar under normal usage conditions and does not cover any damages as a direct result of user misuse or/and abuse.
  • Page 10: Troubleshooting Guide

    Troubleshooting guide The green LED “Standard“ or “StartStop“ does not light up Check for correct connection and specification of the power adapter. Ensure that the original power adapter is used. Specifications: 9 V / DC, 1A Polarity: The foot pedal does not work Check for correct connection of the foot pedal.
  • Page 11 The burner shuts-off due to overtemperature frequently In case of overtemperature increase the air ventilation or change the operation site. Green LED “Button“, “Standard“ or „StartStop“ blinks 2x Ignition failure (see paragraph 4) Green LED “Button“, “Standard“ or „StartStop“ blinks 3x Flame failure (see paragraph 4) Green LED “Button“, “Standard“...
  • Page 12 Notes...
  • Page 13 Technical data: Technology Microprocessor Programs Foot pedal: Standard (flame during pressed foot pedal) Start-Stop with timer, 60 min Button: Start-Stop with timer, 60 min Safety features Safety Control System (SCS): ignition and flame control, temperature monitor with gas safety cut off burner head clogging and assembly monitor (BHC) automatic unit switch off, 4h...
  • Page 14 Instruction manual Power Adapter The range AC plugs 1 - EU 2 - US 3 - AUS 4 - UK Removel 1. Push the release lever (5) down in direction (a) 2. Push the adapter in direction (b) and remove.
  • Page 15 Assembling 1. Select a socket adapter (1-4) suitable for the area of application. 2. Fit the counterpiece on the adapter (7) into the groove (6) and press in direction (c). 3. Push the adapter in direction (d) until you hear its slot into place.
  • Page 16 Notes Argos Technologies 1551 South Scottsdale Court Suite 200 Elgin, IL 60123 Phone: General Telephone: 1-800-886-8675 (USA Only) Local & International: 847-622-0456 Fax: 847-622-0454 Email: info@argos-tech.com Web: www.argos-tech.com...

This manual is also suitable for: