PROGRAMMING
WIRELESS RANGE
This device complies with the Z-Wave standard of open-air, line of sight transmission distances of 100 feet.
Actual performance in a home depends on the numbers of walls between the remote controller and the
destination device, the type of construction and the number of Z-Wave enabled devices installed in the control
network. Most Z-Wave enabled devices act as signal repeater and multiple devices result in more possible
transmission routes which helps eliminate " RF dead-spots." Use the following chart only as a guide to
maximize the signal range.
ADVANCED PROGRAMMING
WARNING:
Advanced programming is recommended ONLY for experienced programmers. The ZWN-RSM1-PLUS has customizable features/ functions that require writing codes. Changes to
code may cause device to function improperly or to not function at all.
The following parameters require that you have an advanced controller. Basic remotes do not have this capability.
All-ON and All-OFF
Depending upon your primary controller, the ZWN-RSM1-PLUS can be set to respond to ALL-ON and ALL-OFF commands in four different ways. Some controllers may not be able to change the
response from its default setting. Please refer to your controller's instructions or technical support for information on whether or not it supports the configuration function and if so, how to change
this setting. The four possible responses for each button (top or bottom button on switch) are:
- Push button on the controller will respond to ALL-ON and the ALL-OFF command (default).
- Push button on the controller will not respond to ALL-ON or ALL-OFF commands.
- Push button on the controller will respond to the ALL-OFF command but will not respond to the ALL-ON command.
- Push button on the controller will respond to the ALL-ON command but will not respond to the ALL-OFF command.
DEVICE INCLUSION/ EXCLUSION
The process of "Inclusion/ Exclusion" is to Add or Remove the device from the Hub. All Z-Wave devices must be "Included"
on the Controller (Hub) before it can be controlled from a smart device. The Hub should be brought physically closer to the
device just for the "Inclusion" process (recommended within 10ft). When finished, the Hub and device can be moved back to
final installation location. Download the App or log onto the website associated with the Hub you are using and follow their
Inclusion/ Exclusion instructions as each Hub's programming and features are different.
• During the Inclusion/ Exclusion process, the Program Button on the relay or the ON/OFF toggle
on the switch can be used for including/ excluding the device.
o When using the ON/OFF toggle, the toggle must be toggled ON and OFF 3 times.
• It is best to perform an Exclusion of the device prior to performing an Inclusion.
Step 1. From the Control Panel, go the the device Exclusion page.
o Select "Exclude Device".
o When prompted, press the Program Button on the Relay once or the ON/OFF toggle on the
switch 3 times.
Step 2. Go to the "Add Device" page.
o Select "Include Device".
o When prompted, press the Program Button on the Relay once or the ON/OFF toggle on the
switch 3 times.
The primary controller should indicate that the action was successful. If the
controller indicates the action was unsuccessful, please repeat from Step 1.
Once the relay is part of the network, the same basic procedure is used to add
the relay to groups & scenes or change advanced functions. Refer to the
Hub's instructions for details.
Step 3. Follow the On-Screen instructions in the Control Panel on adding or removing rooms,
scenes, other devices, and other functions and features.
Unsolicited Report Configuration
ZWN-RSM1-PLUS can send unsolicited status reports to the primary controller (Node ID 0x1) when the switch is toggled
if the controller is designed as a gateway. If your controller is not a gateway or does not need the status reported or you
think it could confuse your Z-Wave network, you can use Command_Class_Configuration to disable this function. By
default this function is disabled.
Configuration Details:
− Parameter number: 3
− Parameter size: 1
− Parameter value: 0.........................Disabled
1.............Send Broadcast