Configuring the Mannequin
4. Connect the blood tank outlet (clear tube located at the top of the blood
tank) to the mannequin BLOOD port on the baffle.
The blood
tank outlet
The BLOOD
port
5. Place the blood tank inside the mannequin's torso.
6. Place the placenta pouch on top of the bleeding tank with no placenta or
umbilical cord inside.
Installing the Boggy/Contracted Uterus With Bag
IMPORTANT: Ensure the blood tank is installed with the use of the postpartum boggy/contracted
uterus, whether or not the bleeding function is used. The postpartum boggy/contracted uterus with
bag is placed inside the abdominal cavity over the blood tank.
NOTE: The uterus bag should be installed and used with the boggy/postpartum uterus at all times.
The uterus has two connections:
• A pneumatic connection to inflate the uterus and create the perception of
a boggy uterus.
• A bleed connection to support vaginal bleeding.
IMPORTANT: Follow these configuration instructions carefully to ensure that no fluid infiltrates
the electrical area inside the mannequin and damages the simulator.
48
The Blood Tank Outlet and Blood Port