SEL-2245-4 AC Metering Module
The SEL-2245-4 provides ac metering inputs for the SEL Axion
SEL-2245-4 modules per system in any combination you want.

Front Panel

Figure 1 SEL-2245-4 AC Metering Module
Schweitzer Engineering Laboratories, Inc.
i6316a
®
. Within an Axion node, install as many as sixteen
Mechanical Installation
Each SEL-2242 chassis/backplane has four or ten slots,
labeled A–J. Slots B–J support the SEL-2245-4 modules.
Figure 2 Notch for Module Alignment
To install an SEL-2245-4 module, tip the top of the
module away from the chassis, align the notch on the
bottom of the module (shown in Figure 2) with the slot
you want on the chassis, and place the module on the
bottom lip of the chassis as Figure 3 illustrates. The
module is aligned properly when it rests entirely on the
lip of the chassis.
SEL-2245-4 Data Sheet

Advertisement

loading
Need help?

Need help?

Do you have a question about the SEL-2245-4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schweitzer Engineering Laboratories SEL-2245-4

  • Page 1: Front Panel

    SEL-2245-4 AC Metering Module ® The SEL-2245-4 provides ac metering inputs for the SEL Axion . Within an Axion node, install as many as sixteen SEL-2245-4 modules per system in any combination you want. Front Panel Mechanical Installation Each SEL-2242 chassis/backplane has four or ten slots, labeled A–J.
  • Page 2: Led Indicators

    Input Connections CAUTION Use supply wires suitable for 60°C (140°F) above ambient. See product The SEL-2245-4 CT/PT analog inputs include a dot next or manual for ratings. to the terminal number to indicate the positive convention. Refer to Specifications for ac analog input ATTENTION ratings and to Figure 5 for terminal assignments.
  • Page 3: Specifications

    Maximum Altitude: 2000 m Magnitude: ±3% @ f and V > 6.7 V, I > 0.6 A AC Metering Inputs (SEL-2245-4) Angle: ±0.2° @ f and V > 6.7 V, I > 0.6A Power and Power Factor (Per Phase and Three-Phase)
  • Page 4 SEL products appearing in this document may be covered by U.S. and Foreign selinc.com • info@selinc.com patents. Schweitzer Engineering Laboratories, Inc. reserves all rights and benefits afforded under federal and international copyright and patent laws in its products, including without lim- itation software, firmware, and documentation.