Table A-10 Uba General Sensor Test Settings - JCM GLOBAL UBA Series Operation And Maintenance Manual

Universal bill acceptor
Table of Contents

Advertisement

Appendix A
DIP Switch
Sensor Name
Conditions
Entrance Sensor
Centering Timing
Sensor
Anti-Pullback
Sensor
1 + 3-6 OFF
Exit Sensor
1 + 3-6 OFF
Anti-Pullback
Home Position
Sensor
Centering Home
Position Sensor
Transport Motor
Encoder Sensor
Stacker Motor
Encoder Sensor
Pusher Plate
Home Position
1-4 + 6 OFF
Sensor
Stacker Detection
Sensor
1-4 + 6 OFF
JCM Part No. 960-000097R_Rev. 3
Universal Bill Acceptor (UBA-1x-SS & x4-SS-SU)

Table A-10 UBA General Sensor Test Settings

Initial DIP Switch Block Setting
Open the Upper Guide to check the Entrance Sensor's condition.
1 ON, &
When the entrance sensor is blocked, the Green LED should
2-6 OFF
illuminate. If the Green LED lights when the Entrance Sensor is
blocked, the sensor's condition is normal.
Open the Upper Guide to check the Centering Timing Sensor's condi-
1 ON, &
tion. When the Centering Timing Sensor is blocked, the RED LED
2-6 OFF
should illuminate. If red LED lights when the Centering Timing Sensor
is blocked, the sensor's condition is normal.
Open the Upper Guide as if to check Entrance Sensor's condition and
block the Anti-Pullback Entrance Sensor. When the Anti-Pullback
2 ON, &
Entrance Sensor is blocked, the Green LED should illuminate. If
Green LED is lights when the Anti-Pullback Entrance Sensor is
blocked, the sensor's condition is normal.
Block the Exit Sensor with a piece of paper or cardboard. When the
2 ON, &
Exit Sensor is blocked, the Red LED should illuminate. If Red LED
lights when the Exit Sensor is blocked, the sensor's condition is
normal.
Rotate the Anti-Pullback Roller with your fingers. When the Anti-Pull-
3 ON, &
back Roller is in its Home position, the Green LED should illuminate.
1-2 + 4-6
If the Green LED flickers ON and OFF while rotating the Anti-Pullback
OFF
Roller, the sensor's condition is normal.
Move the Centering Mechanism with a Hexagonal Nut Driver. When
3 ON, &
the Centering Mechanism is in its Home position, the Red LED should
1-2 + 4-6
illuminate. If the Red LED lights when the Centering mechanism is at
OFF
its Home position, the sensor's condition is normal.
Open the Upper Guide and move the belts forward to check the
4 ON, &
Transport Motor Encoder Sensor. When the Transport Encoder Sen-
1-3 + 5-6
sor is blocked by an interrupter blade, the Green LED should illumi-
OFF
nate. If the Green LED flickers On and OFF as the belts are moved,
the sensor's condition is normal.
Rotate the Stacker gear with a finger. When the Stacker Encoder's
4 ON, &
Sensor is blocked by an interrupter blade, the Red LED should illumi-
1-3 + 5-6
nate. If the Red LED flickers ON and OFF while rotating the gear, the
OFF
sensor's condition is normal.
Remove the Cash Box from the Frame Unit. When the Pusher Home
Sensor's Left Arm is pushed, and the Pusher Home Sensor is
5 ON, &
blocked, the Green LED will be lit (ON). When the Pusher Home
Sensor Arm is released, the sensor is unblocked and the Green LED
will extinguish (go OFF).
Remove the Cash Box from the frame unit. When the Cash Box
5 ON, &
Seated Sensor's right lever is blocked, the Red LED should illumi-
nate. If Red LED goes ON when the Cash Box is set into its fully
seated position, the sensor's condition is normal
NOTE: DIP Switch 7 is
used to
Test Conditions
A - 1 0
Troubleshooting
© 2010, JCM American, Corporation