Table of contents The information herein is correct at the time of issue but may be subject to change without prior notice 1. EC Declaration of Conformity ............... 2. Safety ....................2.1. Important information ................2.2. Warning signs ..................2.3. Safety precautions ................3.
1 EC Declaration of Conformity Revision of Declaration of Conformity 2013-12-03 The Designated Company Alfa Laval Kolding A/S Company Name Albuen 31, DK-6000 Kolding, Denmark Address +45 79 32 22 00 Phone No. hereby declare that Top Unit for Valve Control and Indication Designation ThinkTop®...
Never touch the moving parts if the actuator is supplied with compressed air Never use cleaning agents that will attack the exterior of the ThinkTop D30. Check with your cleaning agent supplier Never clean using Alcohol, Acetone, Chloroform, Methanol, Ammonium chloride and Ammonium Hydroxide etc.
ThinkTop D30 is the first of its kind on the market that focuses on new methods to simplify all aspects of using a basic control unit to minimise and optimise installations instead of using external solenoid valves 3.2 Working principle...
4 Installation 4.3 Installation instructions Step 1 Place the ThinkTop D30 on top of the actuator. Ensure that the unit is correctly mounted by pressing down on top of the ThinkTop D30. Cross-tighten the two allen screws carefully (1.50 Nm).
Page 9
4 Installation Step 4 Install the cable in the cable gland. NOTE Cable connection Cable gland: PG7 (cable dia. ø4.0 - ø6.8 mm) Recommended conductor 0.5 mm (AWG 20). cross section: 2064-0005_1 If the cable gland comes loose from the control head during installation, it must be secured with a tightening torque of 1.50 Nm.
5 Troubleshooting Error scenarios Condition Possible cause Solution Red LED flashing. Insufficient air pressure in the actuator. Check the air supply and the air connections on the unit.
6 Technical data Technical data General Operating pressure 400 - 700 kPa ( 4-7 bar) Supply air quality Class 3 ISO 8573-1 Push-in fittings ø6 mm tube Ambient temperature (operating) -10°C to +50°C Storage temperature (non operating) -15°C to +60°C Protection class IP66 and IP67 IEC 60529...
Need help?
Do you have a question about the ThinkTop D30 and is the answer not in the manual?
Questions and answers