  • Page 1 Instruction Manual ® ThinkTop 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN4 2017-03 Original manual...
  • Page 3: Table Of Contents

    Table of contents The information herein is correct at the time of issue but may be subject to change without prior notice 1. EC Declaration of Conformity ............... 2. Safety ....................2.1. Important information ................2.2. Warning signs ..................2.3. Safety precautions ................3.
  • Page 4: Ec Declaration Of Conformity

    1 EC Declaration of Conformity Revision of Declaration of Conformity 2013-12-03 The Designated Company Alfa Laval Kolding A/S Company Name Albuen 31, DK-6000 Kolding, Denmark Address +45 79 32 22 00 Phone No. hereby declare that Top Unit for Valve Control and Indication Designation ThinkTop®...
  • Page 5: Safety

    Never touch the moving parts if the actuator is supplied with compressed air Never use cleaning agents that will attack the exterior of the ThinkTop D30. Check with your cleaning agent supplier Never clean using Alcohol, Acetone, Chloroform, Methanol, Ammonium chloride and Ammonium Hydroxide etc.
  • Page 6: General Information

    ThinkTop D30 is the first of its kind on the market that focuses on new methods to simplify all aspects of using a basic control unit to minimise and optimise installations instead of using external solenoid valves 3.2 Working principle...
  • Page 7: Installation

    4 Installation 4.1 Product dimensions 2064-0001_1 Ø 105 mm 4.2 Compatible actuators Koltek LKLA-T LKLA SRC long stroke i-SSV Unique SSV Unique SSV long stroke SSV DN80 (76.1 mm) High pressure SSV DN100 (101.6 mm) High pressure SMP valves Unique Mixproof Air/air actuators...
  • Page 8: Installation Instructions

    4 Installation 4.3 Installation instructions Step 1 Place the ThinkTop D30 on top of the actuator. Ensure that the unit is correctly mounted by pressing down on top of the ThinkTop D30. Cross-tighten the two allen screws carefully (1.50 Nm).
  • Page 9 4 Installation Step 4 Install the cable in the cable gland. NOTE Cable connection Cable gland: PG7 (cable dia. ø4.0 - ø6.8 mm) Recommended conductor 0.5 mm (AWG 20). cross section: 2064-0005_1 If the cable gland comes loose from the control head during installation, it must be secured with a tightening torque of 1.50 Nm.
  • Page 10: Operating Led Feedback

    4 Installation 4.4 Operating LED feedback Actuator status LED feedback De-energised Green Energised Yellow Red flashing Alarm (Air pressure)
  • Page 11: Troubleshooting

    5 Troubleshooting Error scenarios Condition Possible cause Solution Red LED flashing. Insufficient air pressure in the actuator. Check the air supply and the air connections on the unit.
  • Page 12: Technical Data

    6 Technical data Technical data General Operating pressure 400 - 700 kPa ( 4-7 bar) Supply air quality Class 3 ISO 8573-1 Push-in fittings ø6 mm tube Ambient temperature (operating) -10°C to +50°C Storage temperature (non operating) -15°C to +60°C Protection class IP66 and IP67 IEC 60529...
  • Page 14: Parts List

    7 Parts list 7.1 Parts list 12.1 12.1 2064-0008_1...
  • Page 15 7 Parts list Parts list Pos. Denomination Top incl. prism and O-rings O-ring Allen screw 12.1 Air fitting Cable gland PG7 X-ring...
  • Page 16 © Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected by laws governing intellectual property and thereto related rights. It is the responsibility of the user of this document to comply with all applicable intellectual property laws. Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval Corporate AB.