Problem Temperature Inaccurate ........ 11 Problem Nutrient reading is inaccurate ....... 11 Problem Won't Hold Calibration ........Warranty Coverage............13 Nutradip 12 Month Warranty Coverage ..... Nutradip Accidental Damage Coverage ....What is not Covered ........... Making a Warranty Claim..........
Meet the GrowBoss Display Panel Push Button Plant Friendly Nutrient Scale High vis LED PPM | 442 | EC Temperature pH 7 Calibration Min | Max trim pot Total Recall pH 4 | 10 Min | Max Nutrient Calibration trim pot...
Before You Begin Before You Begin Your Nutradip GrowBoss is engineered to provide years of Your Nutradip GrowBoss is engineered to provide years of dependable service, however, as with any monitoring dependable service, however, as with any monitoring equipment, it does require periodic calibration and equipment, it does require periodic calibration and maintenance.
Nutradip GrowBoss. Attaching the pH Probe The pH probe uses a twist-lock connector. Ensure the pins on GrowBoss are aligned with the slot on the probe, and push firmly. Twist the locking nut clockwise to tighten. Attaching the Nutrient/Temperature Probe...
This will allow for a more accurate calibration. a more accurate calibration. Place the GrowBoss on a level surface and connect all Place the GrowBoss on a level surface and connect all probes and power supply. Power on the GrowBoss.
Caring for pH Probes Caring for pH Probes The pH Probe is the only component of the GrowBoss that The pH Probe is the only component of the GrowBoss that requires periodic replacement. pH probes age through normal use, requires periodic replacement.
Ensure the probe pins are dry. Caring for Calibration Solutions Caring for Calibration Solutions Your calibration only good solution used to perform calibration. Nutradip manufactures Your calibration only good solution used own calibration solution our Kelowna British...
Follow the steps below until a solution is reached: Follow the steps below until a solution is reached: 1. Check that the Growboss is connected to the 5dcv/0.5 amp 1. Check that the Growboss is connected to the 5dcv/0.5 amp...
Problem Won't Hold Calibration Problem Won't Hold Calibration Follow the steps below until a solution is reached: Follow the steps below until a solution is reached: 1. Power off the unit. Unplug probe(s) and carefully plug back in, 1. Power off the unit. Unplug probe(s) and carefully plug back in, ensuring connections are tight.
The Accidental Damage Coverage plan protects product from The theft coverage plan allows a replacement Nutradip damage caused by user error or negligence. GrowBoss to obtained at a discounted rate in the event of loss or The theft coverage plan allows a replacement Nutradip theft.
2. Accidental damage, faults caused by negligent use or care, neglect, careless operation or handling of the product which is not in accordance with the Nutradip GrowBoss Instruction Manuals. See accidental warranty coverage. 3. Use of parts or accessories other than those produced or recommended by Future Harvest.
Making a Warranty Claim All warranty plans are subject to change without notice. Visit www.futureharvest.com/warranty for more information. Shipping and handling charges may apply. TO THE MAXIMUM EXTENT PERMITTED BY LAW,THIS GUARANTEE AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, GUARANTEES AND REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED.