Lavatory faucet

Advertisement

Quick Links

Lavatory Faucet
Installation and Service Instructions
Installation
Caution: Be sure to turn off hot and cold water supplies
before installing or servicing faucet.
1.
Loosely install the anchor bar (KN-23), spacer (KN-26) and
nut (L-36) on the mounting bolts and place gasket on base
of faucet. Push faucet supplies and anchor bolt/spacer/nut
assemblies with gasket through holes in sink. Secure faucet
to sink by tightening nuts from underside. (If sink or coun-
ter surface is uneven, use putty or sealant to make proper
seal under base.)
2. Connect hot supply to left tube and cold supply to right
tube using appropriate connectors.
3. Pop-up drain installation:
a) Remove pop-up plug, tail piece and flange from the drain
body. Make sure that locknut is threaded all the way
down onto the body with flat friction washer in middle
and beveled washer on top.
b) Apply plumbers putty or sealant to bottom of flange.
c) Install drain body through drain opening in lavatory
and screw flange onto the drain body making sure that
the threads are completely engaged for proper sealing
and strength of the connection. Apply joint compound
to all threaded parts to insure proper seal. Apply putty or
teflon tape to tail piece before attaching to drain body.
d) Tighten locknut to compress the beveled flange evenly
across the bottom of the drain opening taking care not to
over tighten the locknut, causing damage to the lavatory.
e) Remove one of two ball washers from inside the
threaded cavity. Insert pop-up plug and pivot rod into
body. Add one ball washer (the second ball washer
should remain inside the body) to the outside of the ball.
Tighten the retaining nut until the ball is seated on the
internal and external ball washers.
Note: The pop-up plug can be installed either in the remov-
able or non-removable position, depending on the location
of the hole located in the guide at the bottom of the plug.
f) Slide the pivot rod through one side of the spring clip,
then the appropriate adjustment hole and then other
side of the spring clip.
g) Insert lift rod through faucet housing and the top of the
lift strap and secure it in place by tightening the screw.
Note: To ensure proper operation of lift rod and pop-
up, some adjustment of the linkage may be required.
There are two possible adjustment points: 1) lift strap to
lift rod and 2) lift strap to pivot rod.
4. It is very important to thoroughly flush the supply lines to
prevent foreign matter, i.e. copper chips, sand, stones, etc.
from damaging the sealing surfaces of cartridge.
Symmetrix
S-20 Series
5. The handle limit stop can be
6. If when faucet is on and in
Replacing cartridge (KN-4)
1. Remove plug button (KN-157), loosen set screw (L-22) and
2. Engage tabs in cartridge wrench (LN-34) with slots in com-
3. Install new cartridge while taking care to maintain position
4. Reassemble faucet in reverse fashion. Thread cap onto body
5. Set hot water limit stop in accordance with installation step
®
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
Remove aerator and turn valve handle on to full cold posi-
tion, open cold supply. Without closing, turn handle to full
hot and open hot supply. Let water run in hot only and cold
only positions long enough to flush supply lines thoroughly.
Shut off faucet and replace aerator. Check for leaks.
set to limit handle turn to the
hot position. The limit mecha-
nism is factory set to allow full
handle travel. To adjust the
limit stop, turn handle to the
full hot position and lift handle
to open faucet approximately
half way to obtain a smooth
flow for correct initial tem-
perature measurement.
full hot position and water is
too hot, shut off water, remove
plug button (KN-157), loosen
set screw (L-22) and remove
handle (KN-3RB, KN-3BRB or LN-135). Lift limit stop ring
using a small flat head screw driver and rotate clockwise
to lower temperature. If water is not hot enough, rotate
counter clockwise (See Figure 1 above). After correct tem-
perature is achieved, reattach handle, reversing procedure
above.
remove handle (KN-3RB, KN-3BRB or LN-135).
pression ring (KN-2) and use screwdriver in wrench holes or
pliers on wrench and turn counter clockwise until compres-
sion ring engages with cap (LN-8). Continue turning counter
clockwise so that cap/ring assembly is removed from the body
(LN-371). Remove cartridge and o-ring seal (KN-4).
of the o-ring seal at the base of the cartridge. Match posts
in base of cartridge with alignment holes in valve body
during assembly.
firmly by hand. Do not use a wrench which may damage
the finish. Tighten compression ring (KN-2) finger tight
using the wrench (LN-34) then 1/4 to 1/2 turn further.
5 above.
Figure 1
Limit stop adjust

Advertisement

loading
Need help?

Need help?

Do you have a question about the Symmetrix S-20 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Symmons Symmetrix S-20 Series

  • Page 1 Symmetrix ® For California Residents Lavatory Faucet S-20 Series WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or Installation and Service Instructions other reproductive harm. Installation Remove aerator and turn valve handle on to full cold posi- Caution: Be sure to turn off hot and cold water supplies tion, open cold supply.
  • Page 2 0.5 gpm (1.9L/min) ---- LN-100* P-26 Removal tool part number, LL-60K RL-154 ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-962 ■ ■ ■ ■ Copyright © 2017 Symmons Industries, Inc.
  • Page 3 Symmetrix ® For California Residents Lavatory Faucet S-20-BH Series WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or Installation and Service Instructions other reproductive harm. Caution: Be sure to turn off hot and cold water supplies before some adjustment of the linkage may be required.
  • Page 4 (non-aerated) RL-154 0.5 gpm (1.9L/min) ---- LN-100* Removal tool part number, LL-60K ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-962 ■ ■ ■ ■ Copyright © 2017 Symmons Industries, Inc.

This manual is also suitable for:

Symmetrix s-20-2-bhSymmetrix s-20-2Symmetrix s-20-bh series