Page 2
Pantheon is a low voltage DC mini rolling door operator, manufactured exclusively for and distrib- uted by Janus International. It is designed to fit neatly inside the torque tube of the rolling door, re- quiring no additional side room. Pantheon features the latest in electronic technology combined with innovative engineering and a patented design, and electronic limits can not be “lost”...
Page 3
Low Voltage DC motors Thermal overload protection device to UL325 • Quiet, safe and efficient operation • Internal Planetary Gearing Mechanism Gear system that provides for great capacity to operate the rolling door • Motor runs at optimum efficiency—gear system does the “work” •...
Page 4
Twin CPU Processors Designed to offer increased operational capacity • Computing power equivalent to early PCs • 8 bit processors with 4K x 13 bit OTP ROM • Processors designed with high speed low power CMOS technology • Plug in Style Terminal Connectors For the simple and reliable con- •...
Page 5
Diagnostic Fault System Designed to provide a series of audible “beep” sounds to indicate certain fault conditions • Simple trouble shooting process intended to quickly identify and resolve fault conditions • From…No “beep” = check the power is ON • Right through to Three “beeps”...
Page 6
Edge Sensor Device—Connection Plug in terminal connection for simple wiring of two wire edge • sensor—external entrapment device NC or NO contact selection • External Receive Device—Connection Plug in terminal connection for simple wiring of external receiver device • 12 or 24 V DC power available to suit device •...
Page 7
Fuse Protection Replaceable “slow blow” type fuses are fitted where required to provide protection for the circuit • board and where external accessories require DC power from the logic controller CIRCUIT BOARD POWER INDICA- DC OUTPUT POWER TOR LED LIGHT PROTECTION FUSE FOR AND PROTECTION EXTERNAL ACCESSO-...
Page 8
1-2-3. The Janus Pantheon Operator is a stronger and easier to install DC motor operator for today’s door industry, featuring a simple floor level manual release system, soft start and soft stop operation. The electronic limits of the operator can be...
Page 9
INSTALLATION INSTRUCTIONS COMMERCIAL MODEL www.janusintl.com...
Page 10
DO NOT attempt to install the rolling door unless you have read , understood and acknowledged the installation instructions provided for the commercial rolling door. DO NOT attempt to install or commission the Pantheon operator or any accessories unless you have read, understood and acknowledged the instructions provided.
IMPORTANT SAFETY INSTRUCTIONS THE FOLLOWING SAFETY INSTRUCTIONS RELATE TO THE OPERATION OF THE PANTHEON COMMERCIAL ROLLING DOOR OPERATOR WARNING !! —TO REDUCE THE RISK OF DEATH OR SEVERE INJURY ALL OF THE FOLLOWING INSTRUCTIONS MUST BE READ, ACKNOWLEDGED AND ADHERED TO.
INSTALLATION INSTRUCTIONS STEP 1 Connecting manual “ release cable to the drive unit” Remove the split nut Uncoil the manual release cable and insert the free end of the cable into the threaded recess Withdraw (spring loaded) pin and twist to engage manual release Fit split nut and tighten Carefully coil cables together and secure with a cable tie or similar to...
Page 13
INSTALLATION INSTRUCTIONS STEP 2 “Fitting the dual anchor bracket to the drive unit” Insert the two steel tubes into the anchor bracket Carefully insert the two tubes of the assembled bracket into the corresponding sections of the drive unit E n s u r e t h a t m a x i m u m penetration of the tubes into...
Page 14
INSTALLATION INSTRUCTIONS STEP 3 “Preparing for the installation of the rolling door” Withdraw the manual release pin— twist and lock in the manual condition to allow the drive unit to rotate freely The drive unit is fitted inside the drum assembly of the rolling door Carefully slide the drive unit along the axle of the rolling...
Page 15
Ensure the drive unit is correctly fitted inside the door drum assembly and fully engaged in the steel drum wheel Install the rolling door to the door brackets as outlined in the Janus installation guide Spring tension and curtain clearances should be maintained as per normal practice A U-bolt &...
Page 16
INSTALLATION INSTRUCTIONS STEP 5 “Fitting the logic controller” Carefully uncoil the cables from the drive unit and locate them such that they are protected from any mechanical damage Locate a suitable position for the fitment of the logic controller ensuring adequate free cable length The logic controller shall be installed on the same side of the opening as the drive unit...
Page 17
INSTALLATION INSTRUCTIONS STEP 5 “fitting the logic controller….(continued)” Once the logic controller enclosure is secured to the structure—locate the drive unit cable and the electronic limit cable. Fit the electronic limit cable plug through the hole provided bottom enclosure—use care to ensure correct fitment Fit the cable gland &...
Page 18
This handing feature does not RH OPERATION apply to Pantheon “mini “ - operators All Pantheon “mini “operators will have the direction jumper removed and fitted to the JSS (Mini) position – as standard factory issue NOTE OF CAUTION !!
Page 19
INSTALLATION INSTRUCTIONS STEP 7 “Setting the electronic limits” “learn” Ensure the drive unit is engaged for normal “auto” operation and the power is ON. 1. Press and hold LEARN button until three BEEP sounds are heard The logic controller will learn the OPEN position “open position”...
Page 20
INSTALLATION INSTRUCTIONS STEP 8 “Setting the sensitivity adjustment” The Pantheon logic controller is designed to electronically detect and monitor the normal operation of the door. This ensures that operator shall automatically stop and reverse its closing motion or alternately stall its opening motion if an obstruction is detected.
Page 21
INSTALLATION INSTRUCTIONS STEP 9 “Adusting the sensitivity” This feature allows for the logic controller to adjust for small operational imbalances and permit the door to operate as required in both directions in conjunction with the electronic sensitivity setting Adjustments shall be made once the electronic sensitivity setting has been confirmed —...
Page 22
INSTALLATION INSTRUCTIONS STEP 10 “Fitting the manual chain hoist” The manual chain hoist assembly may be fitted to either side of the anchor bracket as may be required to suit the installation Insert the shaft into the anchor bracket section - rotate to engage the mating hexagonal sections ( NB.
Page 23
INSTALLATION INSTRUCTIONS STEP 11 “Fitting the manual release ” Locate manual release cable ensuring that smooth lever operation is maintained Avoid tight bends and promote generous inner cable movement Locate a suitable position for the lever device Secure the lever mechanism to the structure with the lever moved toward the right to actuate - full auto operation Re engage the manual release pin at the...
Page 24
Check all manual locks are any external accessories. inoperable Remove “test plug” at photo Contact Information: electric sensor terminal if fitted Janus International 134 Janus International Blvd. Demonstrate all functions to Temple, GA 30179 client and hand over any accessory items or 770.562.2850 documentation 770.562.1991 fax...
Need help?
Do you have a question about the Pantheon and is the answer not in the manual?
Questions and answers