reMOve Dryer linT
FilTer HOuSinG
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the dryer front panel
(See page 4-60).
2.
Remove four 1/4" hex head screws. If the
two screws going into the blower housing
are brass, and the others are not, they must
be replaced in the same location they are
removed from.
3.
Pull the lint filter housing away from dryer.
TeCH TiP: Excess blower vibration may
be reduced by loosening the top left screw
in the lint filter housing, up to two full turns.
Make sure the foam insulation blocks
any gaps. Add more foam insulation or
aluminum duct tape to seal up any gaps that
are created.
Two 1/4" Hex
Head Screws
Two 1/4" Hex
Head Screws
4-61
Need help?
Do you have a question about the W10376697 and is the answer not in the manual?