Olimpia ISSIMO 11 User Manual

Olimpia ISSIMO 11 User Manual

Advertisement

1.0

Technical data:

DESCRIPTION
Cooling power (1) / (3)
Input power in cooling (1)
Nominal absorption (1)
Annual consumption of energy in cooling (1)(Dir.2202/31/EC)
E.E.R.
Energy efficiency class in cooling (3)
Supply voltage
Minimum/maximum supply voltage
Maximum input power (2)
Maximum absorption (2)
Dehumidification capacity
Air flow rate (max)
Ventilation speed
Pipe length
Electrical resistance (optional)
Maximum remote control range (distance/angle)
Dimensions (Width x Height x Depth)
Weight (without packaging)
Noise (sound power)
Enclosure protection rating
Refrigerant/load
Max operating pressure
Power lead
Fuse
Maximum operating temperature in cooling
Minimum operating temperatures in cooling
(1) Test conditions to verify cooling power (EN 14511)
(2) High load test conditions
(3) Test conditions for verifying the efficiency class (EN 14511)
ISS0011R10_A_EN.doc
ISSIMO 11
Unit of measurement
No. poles x sect. mm
Indoor temperature
DB 35°C - WB 24°C
DB 18°C - WB 16°C
Indoor temperature
DB 27°C - WB 19°C
DB 35°C - WB 24°C
DB 35°C - WB 24°C
kW
W
A
kWh
-
-
V-F-Hz
V
W
A
l/h
3
m
/h
-
m
W
m/°
mm
Kg
db(A) min-max
-
Type/Kg
MPa
2
-
Outdoor temperature
DB 43°C - WB 32°C
DB 18°C - WB 16°C
Outdoor temperature
DB 27°C - WB 19°C
DB 43°C - WB 32°C
DB 35°C - WB 24°C
Values
3,0
1034
4,6
517
2,64
A
230-1-50
196 / 253
1175
5,2
1,2
380-300-250
3
1,5
-
8 / 80°
520x485x550
36
34 - 43
IP20
R410A
5,2
3 x 1.5
10AT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISSIMO 11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Olimpia ISSIMO 11

  • Page 1 ISSIMO 11 Technical data: DESCRIPTION Unit of measurement Values Cooling power (1) / (3) Input power in cooling (1) 1034 Nominal absorption (1) Annual consumption of energy in cooling (1)(Dir.2202/31/EC) E.E.R. 2,64 Energy efficiency class in cooling (3) Supply voltage...
  • Page 2 4-speed centrifugal fan motor with a maximum input power of 200W; • IR remote control with Olimpia Splendid serial protocol • Unico Olimpia Splendid user interface board, from here on in called ‘display unit’; • NTC temperature probe with standard cylindrical container and connecting wire •...
  • Page 3 PARAMETERS TABLE Mnemonic Value Description Expected range Scale_m 18° C Minimum scale 10…32° C Tset 22° C Setpoint 10…38° C 2° K Hysteresis 0.5…10° K 0° K Ambient probe input calibration -15…+15° K tmin 22° C Anti-ice formation temperature 10…30° C tmax 32°...
  • Page 4 COOLING MODE • Selectable only with the remote control. The fan is always powered working at the speed selected even if the compressor is powered (except for the possible triggering of the anti-explosion sub programme), otherwise it works at minimum speed. If automatic fan speed is selected (on the remote control) the following is applicable (only with the compressor ON –...
  • Page 5 AUTOMATIC MODE • Selectable either on the remote or on the display-unit pressing the key for at least 5 seconds (in the latter case only with the machine previously on STANDBY, no ongoing malfunctions and after DIAGNOSTICS, specified below). In this mode, also signalled locally on the display-unit when LED DL4 turns on, either the COOLING or FAN function is selected automatically depending on the constantly monitored room temperature: -If Tamb>23°C the fan works at minimum speed;...
  • Page 6 10. DISPLAY INDICATIONS DESCRIPTION GREEN LED YELLOW LED GREEN LED RED LED Standby Machine on Timer(s) on Automatic operation Malfunctions “Dirty filter” malfunction ON L* ‘Probe KO’ malfunction ON L* ON L* ON L* SELF-TEST operation ON L* ON L* ON L* ON L* *) ON L = blinks for 1 second ON, 1 sec.
  • Page 7 ISS0011R10_A_EN.doc...

Table of Contents

Save PDF