ISSIMO 11 Technical data: DESCRIPTION Unit of measurement Values Cooling power (1) / (3) Input power in cooling (1) 1034 Nominal absorption (1) Annual consumption of energy in cooling (1)(Dir.2202/31/EC) E.E.R. 2,64 Energy efficiency class in cooling (3) Supply voltage...
Page 2
4-speed centrifugal fan motor with a maximum input power of 200W; • IR remote control with Olimpia Splendid serial protocol • Unico Olimpia Splendid user interface board, from here on in called ‘display unit’; • NTC temperature probe with standard cylindrical container and connecting wire •...
Page 3
PARAMETERS TABLE Mnemonic Value Description Expected range Scale_m 18° C Minimum scale 10…32° C Tset 22° C Setpoint 10…38° C 2° K Hysteresis 0.5…10° K 0° K Ambient probe input calibration -15…+15° K tmin 22° C Anti-ice formation temperature 10…30° C tmax 32°...
Page 4
COOLING MODE • Selectable only with the remote control. The fan is always powered working at the speed selected even if the compressor is powered (except for the possible triggering of the anti-explosion sub programme), otherwise it works at minimum speed. If automatic fan speed is selected (on the remote control) the following is applicable (only with the compressor ON –...
Page 5
AUTOMATIC MODE • Selectable either on the remote or on the display-unit pressing the key for at least 5 seconds (in the latter case only with the machine previously on STANDBY, no ongoing malfunctions and after DIAGNOSTICS, specified below). In this mode, also signalled locally on the display-unit when LED DL4 turns on, either the COOLING or FAN function is selected automatically depending on the constantly monitored room temperature: -If Tamb>23°C the fan works at minimum speed;...
Page 6
10. DISPLAY INDICATIONS DESCRIPTION GREEN LED YELLOW LED GREEN LED RED LED Standby Machine on Timer(s) on Automatic operation Malfunctions “Dirty filter” malfunction ON L* ‘Probe KO’ malfunction ON L* ON L* ON L* SELF-TEST operation ON L* ON L* ON L* ON L* *) ON L = blinks for 1 second ON, 1 sec.