SWIMMING POOL HEAT PUMP UNIT CONTENTS 1. Preface 1 2. Spec 2.1 Performance Data of Swimming Pool Heat Pump Unit 2 2.2 Dimensions for Swimming Pool Heat Pump Unit 4 3. Installation and Connection 9 3.1 Installation of System 9 3.2 Swimming Pool Heat Pumps Location 10 3.3 How Close to Your Pool? 10 3.4 Swimming Pool Heat Pumps Plumbing 11...
1. PREFACE In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit.
2.SPECIFICATION 2.2 Dimensions for Swimming Pool Hea t Pump Unit PHFD-02610 PHFD-02615 PHFD-02620 1010 PHFD-02625 version 3, release 05th Nov 2017...
Page 7
2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit PHFD-02630 1114 PHFD-02640 1114 PHFD-02645 PHFD-02650 1114 1250 PHFD-02660 PHFD-02670 1114 1250 version 3, release 05th Nov 2017...
Page 8
2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit PHFD-02710 PHFD-02712 1050 640 1650 300 1525 PHFD-02713 PHFD-02714 version 3, release 05th Nov 2017...
Page 9
2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit PHFD-02715 1005 1276 1614 304 1350 1525 PHFD-02720 version 3, release 05th Nov 2017...
Page 10
2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit PHFD-02730 1276 2410 305 1350 1525 PHFD-02740 version 3, release 05th Nov 2017...
3.INSTALLATION AND CONNECTION 3.1 Installation illustration Va lve W a te r ou tlet W a te r s upp ly P ool (o r o th e Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer.
3.INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1 . Fresh Air - 2. Electric ity - The unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier.
3.INSTALLATION AND CONNECTION 3.4 Swimming Pool Heat Pumps Plumbing ccording to the nameplate). The Temperatures, The unit does not need copper heat sink piping. PVC pipe can be run straight into the unit. Location: Connect the unit in the pool pump return and upstream of any chlorinators, ozonators or chemical pumps.
3.INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it required to protect you against short circuits inside the unit. Bonding is also required. The unit has a separate molded-in junction box with a standard electrical conduit nipple already in place.
4.Usage a d Opera i n 4.1. Function of controller power water temperature setting timer BUTTON NAME FUNCTION power ON/OFF Change Mode or increase parameter values down Manual defrost or increase parameter values setting Inquiries and setting Query and set parameters timer Timing CAUTION: Only after unlocking can perform any operation...
4.USAGE 4.2 Usage of the controller 4.2.1 How to start heat pump The unit can be turnedON/OFFbypressing“power”. When the display ----"heating" mode When the display ----"cooling" mode When the display ----”auto” mode power power Press”power” Inlet water water water temperature temperature temperature setting...
Page 17
4.USAGE 4.2.3 How to set your desired water temperature. After unlocking, Regardless of unit operation or standby mode can set your desired water temperature.Press"▲"or "▼"."Set temperature"symbolstarts flashing anddisplay water set temperature, then fingerpress"▲"or“▼"key, you can change the water temperatur e setting. power power press"▲"...
Page 18
4.USAGE 4.2.5 How to check parameter setting & measured values of current status. After unlocking, Click "setting" , Enter the query parameter mode power power press "setting" water temperature setting setting timer timer inquire Hint: When the system is a dual system, you can continue to query b1 to Er; three systems can continue to query C1 to Er;...
Page 19
4.USAGE The heat pump consists of two separate timing functions. Timer 01 and 02 are used to set the ON/OFF times of the heat pump within 24 hour period. Heat pump ON/OFF timers: 01---- ON/OFF timing 02----ON/OFF timing After unlocking, Press the "timer" key and enter timer 01 ON time as in clock setting section. Press “timer ” key again to set timer 01 OFF time.
4.USAGE 4.3 Parameter table Parameter name Channel Adjustment range Initial value Pool water temperature Pool water temperature display deviation value 0℃─15℃ Compressor starts with the set temperature deviation 1℃─15℃ 0~120 min Water pump run mode Set max. temperature 10℃─80℃ 0℃─35℃ Allow the auxiliary heating of the ambient temp.
5. MAINTENANCE AND INSPECTION Check the water supply device and the release often. You should avoid the condition of no it's performance and reliability. You The area around the unit should be dry, clean and well ventilated. Clean the side heating exchanger regularly to maintain good heat exchange as conserve energy .
6.APPENDIX 6.1 .Caution & Warning dealer. for Europe market This appliance can used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Page 24
6.APPENDIX Single phase unit Nameplate maximum Phase line Earth line Creepage protector Signal line current No more than 10A 30mA less than 0.1 sec 1.5mm 1.5mm 2 2.5mm 2 2.5mm 2 10~16A 30mA less than 0.1 sec 2 4mm 2 4mm 2 16~25A 30mA less than 0.1 sec...
Page 25
6.APPENDIX 3. Circuit diagram of the unit PHFD-02615 PHFD-02620 version 3, release 05th Nov 2017...
Page 26
6.APPENDIX 3. Circuit diagram of the unit PHFD-02625 PHFD-02630 version 3, release 05th Nov 2017...
Page 27
6.APPENDIX 3. Circuit diagram of the unit PHFD-02640 PHFD-02645 PHFD-02650 PHFD-02660 version 3, release 05th Nov 2017...
Page 28
6.APPENDIX 3. Circuit diagram of the unit PHFD-02710 PHFD-02712 PHFD-02713 PHFD-02714 version 3, release 05th Nov 2017...
Page 29
6.APPENDIX 3. Circuit diagram of the unit PHFD-02715 version 3, release 05th Nov 2017...
Page 30
6.APPENDIX 3. Circuit diagram of the unit PHFD-02720 version 3, release 05th Nov 2017...
Page 31
6.APPENDIX 3. Circuit diagram of the unit PHFD-02730 version 3, release 05th Nov 2017...
Page 32
6.APPENDIX 3. Circuit diagram of the unit PHFD-02740 version 3, release 05th Nov 2017...
Need help?
Do you have a question about the PHFD-02610 and is the answer not in the manual?
Questions and answers
01 codes what is problem
Error code E1 indicates a "Wrong phase" for the Aqua model PHFD-02610.
This answer is automatically generated