Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning or replacement of the filters.
1. Fan maintenance (once per year).
Take off the ventilation unit and clean the fan
blades.
Remove dust using a soft brush, cloth or a
vacuum cleaner.
Do not use water, abrasive detergents, solvents,
sharp objects for cleaning.
The impeller blades must be cleaned once in
year.
2. Regenerator and filter maintenance (3-4 times per year).
Remove the air flow rectifier.
1.
Remove the filter in front of the regenerator.
2.
Pull the regenerator cord to remove the
3.
regenerator from the air duct.
Be careful while pulling the regenerator to
4.
avoid its damage.
Remove the filter behind the regenerator.
5.
Clean the filters as often as required, but at least
3 times a year.
After completion of the period set for the
motor hour meter (factory setting 90 days)
the filter replacement indicator in the bottom
of the mounting plate glows to indicate the
need of the filter cleaning of replacement.
Wash the filters, let those dry out and install
the dry filters inside the air duct.
Vacuum cleaning is allowed.
The filter rated service life is 3 years.
Contact the Seller for spare filters.
DISCONNECT THE UNIT FROM POWER SUPPLY
BEFORE ANY MAINTENANCE OPERATIONS!
VENTILATOR MAINTENANCE
Take off the ventilation unit
Air flow rectifier
Air flow rectifier
Filter
Ceramic regenerator
Filter

MAINTENANCE

Clean the impeller blades
15