5
5.1
Fault display
Error is alternatively displayed with the running mode.
Six seconds after major error, the system is resetting automatically.
The automatic reset can be interrupted if the top button Naviblu is active at the end of six seconds.
13
15
09
0 000 000
01
04
05
08
010101
010101
09
10
11
12
13
15
> 130°
16
< 30°
20
26
A
31
32
48
FAULT
AUTO
Motor temperature
too high
Intrusion
EEprom
ROM RAM Problem
Encoder
Motor
Broken arm
Obstacle on opening
Obstacle on closing
Width too wide
Width too small
Software error
Motor current fault
Monitored safety 1
Monitored safety 2
SEVERITY
ACTION
Repairable
Allow to cool
Indicative
Critical
Automatic reset.
Critical
Automatic reset.
Automatic reset*
Critical
*If the problem continues, contact your sales
department
Automatic reset*
Critical
*If the problem continues, contact your sales
department
Critical
Automatic reset.
Indicative
Remove the obstacle
Indicative
Remove the obstacle
Critical
Automatic reset.
Critical
Automatic reset.
Critical
Automatic reset
Critical
Automatic reset.
A safety continuously detects.
Indicative
Contact your sales department
A safety continuously detects.
Indicative
Contact your sales department
Need help?
Do you have a question about the ISO 3 and is the answer not in the manual?
Questions and answers