“Semi Stand-By” To “Stand-By” Flowchart - Philips 32PFL7403D/10 Service Manual

Chassis q528.2e lb. me8+
Hide thumbs Also See for 32PFL7403D/10:
Table of Contents

Advertisement

Service Modes, Error Codes, and Fault Finding
Important remark:
release reset audio 10 sec after
entering standby to save power
Semi Stand by
If ambientlight functionality was used in semi-standby
(lampadaire mode), switch off ambient light (see CHS
ambilight)
Delay transition until ramping down of ambient light is
finished. *)
transfer Wake up reasons to the Stand by µP.
Switch Memories to self-refresh (this creates a more
stable condition when switching off the power).
Switch AVC system in reset state
Wait 10ms
Switch the NVM reset line HIGH.
Disable all supply related protections and switch off
the DC/DC converter (via the Enable-3V3 I/O line)
Wait 5ms
switch off the +1V2 DC/DC converters
Switch OFF all supplies by switching HIGH the
standby I/O line..
Stand by
Figure 5-9 "Semi Stand-by" to "Stand-by" flowchart
Q528.2E LB
5.
*) If this is not performed and the set is
switched to standby when the switch off of
the ambilights is still ongoing, the lights will
switch off abruptly when the supply is cut.
I_17960_065.eps
EN 31
220508

Hide quick links: