Elevation Factor - Linertec LTS-200 Series Instruction Manual

Total station linertecexpress on-board application
Hide thumbs Also See for LTS-200 Series:
Table of Contents

Advertisement

1. PRIM.MAES KEY
 
 
 
2. SEC.MEAS KEY
 
 
 
3. EDM MIN DISP/QUICK 1. 1mm/OFF
 
4. SHOT COUNT
 
 
 
5. SHOT INPUT
Please refer to the instruction manual of basic function about details of each setting.

5.5.9 Elevation factor

"Elevation Factor" as used here refers to Average Elevation Correction and Scale Factor
carried out as part of the measurement process among the special functions.
It is effective only with MEAS-Rect., FREE, CALC-Traverse, and VPM. These reverse
corrections are carried out with STAK (Stake Out, Point To Line). When the instrument is
shipped from the factory, the 1.AVE.ELEV. is set to "0" and the 2.SCALE FACT to "1" so
that no correction is carried out.
If correction is necessary, input the appropriate values for the AVE.ELEV and SCALE
FACT.
1. MEAS. SHOT
2. MEAS. CONT
3. TRACK SHOT
4. TRACK CONT
1. TRACK CONT
2. TRACK SHOT
3. MEAS. CONT
4. MEAS. SHOT
2. 1mm/ON
3. 0.1mm
1. 1 TIME
2. 3 TIMES
3. 5 TIMES
4. INPUT
XX TIMES
Sa
H
Sb
Sc
RH
H