ZURN Z880 Installation Instructions Manual

ZURN Z880 Installation Instructions Manual

Shallow trench drain system

Advertisement

Dimensional data (inches and [mm]) are subject to manufacturing tolerances and change without notice.
WARNING: Cancer and Reproductive Harm -
ADVERTENCIA: Cáncer y daño reproductivo -
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction -
Zurn Industries, LLC
|
Specification Drainage Operation
1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
In Canada
|
Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com
Z880
SHALLOW TRENCH DRAIN SYSTEM INSTALLATION INSTRUCTIONS
www.P65Warnings.ca.gov
www.P65Warnings.ca.gov
www.P65Warnings.ca.gov
Rev.
A
Date:
5/15/2018
C.N. No.
140024
Form No. FT902
Page 1 of 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z880 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZURN Z880

  • Page 1 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Zurn Industries, LLC Specification Drainage Operation Rev. 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 Date: 5/15/2018...
  • Page 2 Above are some of the trench drain components typical to an installation. Double check your order to ensure that you have all components particular to your job before beginning your installation. Contact Zurn ‘Flo-Thru’ at 855-663-9876 should additional material be required. Zurn Industries, LLC Specification Drainage Operation Rev.
  • Page 3 Soft and/or shifting soil substrates may cause cracking of the concrete and consequent movement of the trench. It is critical that the concrete be poured on an adequate foundation. Zurn Industries, LLC Specification Drainage Operation Rev.
  • Page 4 The bottom interlock should snap together. A silicone caulk, or a construction adhesive, such as Liquid Nails, is recommended to be used at each joint as a sealer. Zurn Industries, LLC Specification Drainage Operation Rev.
  • Page 5 It may be necessary to remove a underside rib to allow the outlet to sit flat. A hole saw can be used to cut the appropriate size hole through the bottom of the trench. Zurn Industries, LLC Specification Drainage Operation Rev.
  • Page 6 Dimensional data (inches and [mm]) are subject to manufacturing tolerances and change without notice. Upon completion of the trench excavation, the channels should be placed in order alongside the excavation and according to the job layout. Zurn Industries, LLC Specification Drainage Operation Rev.
  • Page 7 1/16” [1.6mm] below the floor grade. Remember to compensate for concrete shrinkage that may occur durning cure so that the edge of the trench drain does not protrude above the finished floor grade. Zurn Industries, LLC Specification Drainage Operation Rev.